![COMPANION 10000072 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/companion/10000072/10000072_owners-manual_2644807012.webp)
12
Situation
Probable Cause
Solution
Power outlets are not working
Check power station is turned on
and relevant outlet power is turned
on
Turn on the power outputs by
pressing theindividual power button
after the power station is on.
Fridge connected but
not running
Check power station is turned on
Turn power station on
Check power station has sufficient
charge
If low charge, charge the power
station as per the user manual
instructions
Check the battery monitor on the
fridge is set to Low or Medium
battery monitor setting
Set fridge battery monitor to the Low
or Medium setting
Solar not charging the
power station
Check solar is connected correctly
Check all connections from the
solar panel to the power station are
secure
Check solar panel is set up correctly Point solar panels towards the
sun. Make sure there is no inline
controller/regulator before the power
station
DC charger not working
Check the inline fuse
If fuse is broken replace with a 10A
blade fuse
Alarm LED is flashing
This will be caused by either over
temperature, under temperature
protection, overvoltage protection,
undervoltage protection, overcurrent
protection, short circuit protection or
incorrect polarity protection
Remove all Inputs and Outputs and
turn the power station off and back
on. If the warning is still there -
check the current temperature. The
operating temperature should be
between -10 and 40°. Depending
on the temperature try moving to a
cooler or warmer spot
TROUBLE SHOOTING