background image

G:\Masters\Installation Sheets\Master & Premier\MMR400S Aviation Installation Sheet.doc 

Page 7 of 18 

8. 

Electrical Connections 

Prior to pump installation ensure that there is at least a two-metre tail on the incoming 
underground mains supply / pump contactor cable and comms cable (if comms enabled). These 
cables are terminated at the C4000 power supply, which is housed in the flameproof enclosure 
located in the bottom of the pump, behind the door. 
Mains power wiring should be rated for a maximum current draw of 10 A rms at 220-240 V ac. 
Refer to AS/NZS 60079.14

 

for appropriate cabling. 

When replacing the lid of the flameproof enclosure, ensure the sealing O ring is in place. 

Note:

 All cables entering the power supply must be glanded with approved 20mm flameproof 

glands. 

Note:

 Output to submersible pump(s) is 230 V ac, 300 mA max. It is wired to the pump 

contactor/relay at the switchboard and not directly to the pump. 

Note:

 Pump comm’s connect to pump controller such as DCA, CommunicatorController etc. 

(option). Comms cable is not intrinsically safe. 
 

 

 

8.1 

Submersible Pump connections 

  

Connect the feeds to the submersible pump relays / contactors to the C4000 Power Supply as 
follows: 
Pump supplying side A to terminal marked T1  
Pump supplying side B to terminal marked T4 (not used on single hose dispensers) 
If both sides are required to switch the same submersible pump then T1 and T4 should be linked 
together. 
 

Note:

 

Dispensers do not use the terminals marked LOAD 1 & 2. 

Содержание Master MMR400S Aviation

Страница 1: ...kland 1061 New Zealand PO Box 12 417 Penrose Auckland 1642 New Zealand Tel 64 9 579 2094 Fax 64 9 579 0635 info compac co nz www compac co nz Installation and Setup Instructions Model Master Version M...

Страница 2: ...and Nozzles 8 9 1 Breakaways 8 10 Electrical Commissioning C4000 8 11 Mechanical Commissioning and Air Purge 9 12 Setting up the C4000 9 12 1 Configuration Codes 9 12 2 Submersible Delay Sd 10 12 3 Pr...

Страница 3: ...stallation and operating conditions may affect the unit s performance Compac Industries Limited has no control over each installation s unique operating environment Hence Compac Industries Limited mak...

Страница 4: ...G Masters Installation Sheets Master Premier MMR400S Aviation Installation Sheet doc Page 4 of 18 2 Footprint...

Страница 5: ...al regulations The dispensing equipment shall be installed to prevent the delivery hose from contacting the ground when not in use Where local regulations require a sump to be fitted a Sumps must be p...

Страница 6: ...es while working in the Flame proof box Operating the unit with these incorrectly set can result in damage to the C4000 Power Supply or incorrect operation of the solenoid These switches are set in th...

Страница 7: ...sure ensure the sealing O ring is in place Note All cables entering the power supply must be glanded with approved 20mm flameproof glands Note Output to submersible pump s is 230 V ac 300 mA max It is...

Страница 8: ...XD LED D6 will poll If the dispenser responds to polls for its respective pump number s Comms TXD LED D7 will also poll Diagnostic LED D18 slowly flashing If the dispenser is connected to an operation...

Страница 9: ...eck all the dispenser fittings solenoids and pipework for leaks 7 Turn side A switch off and connect the hose to a suitable tank or container Turn side A switch on again 8 The display and tote should...

Страница 10: ...elease the K factor switch repeatedly until Pcut appears on the Dollar display 3 Increase the Pcut setting and do another delivery Adjust the Pcut setting again if required The maximum value that the...

Страница 11: ...the litres display and PrA is displayed on the money display 3 Press and hold the Parameter switch A digit of the displayed Price per litre will begin to increment 4 When the digit is correct release...

Страница 12: ...Factor switch is shown in the diagram below J1 Comms Test J7 Displays J13 Not used J2 To Power Supply J8 Temperature for Temperature compensation only J14 Not used J3 Input from KG Meter Side A J 9 P...

Страница 13: ...o a certified measuring container and compare the display value with the amount dispensed Example Display shows 10 00 True volume 20 00 To calculate the correct K Factor from the information above fir...

Страница 14: ...roller If the pump is connected to a controller check that pump data and transaction information is being correctly uploaded to it Refer to the controller manual for specific instructions regarding co...

Страница 15: ...exceeded Err 8 Excess reverse rotation of encoder Check product is not flowing back into the tank once the delivery has finished Err 9 Faulty or disconnected meter encoder 1 Check that encoder is plug...

Страница 16: ...A K C4000 microprocessor board F CP C4PROCES A COM250 meter complete F METER COM250AS COM250 Flowmeter electronics F METER 125 250E ACV Valve P VALVE ACV 2 Solenoid Coil F D SCI08COIL10W C4000 Power...

Страница 17: ...o the unit Phone number if dial in site Merchant ID number Eftpos site 21 Contact Details Service Agent Phone E mail Address 1 Address 2 22 Notes Manufacturer Contact Details The Compac Master Dispens...

Страница 18: ...ation Sheet doc Page 18 of 18 23 Revision History Previous revision date Summary of changes New document 26 06 14 Added sump info in accordance with EPA File ref COM 09 29 Added Electrical and Mechani...