INSTALLATION CONSIDERATIONS 

This fiber-optic link is supplied as a Standalone/Rack module. Units 
should be installed in dry locations protected from extremes of 
temperature and humidity.

C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS

CAUTION:

 Although the units are hot-swappable and may be installed 

without turning power off to the rack, ComNet recommends that 
the power supply be turned off and that the rack power supply 
is disconnected from any power source. 

Note:

 Remove electrical 

connector before installing in card cage rack.

1.  Make sure that the card is oriented right side up, and slide it into 

the card guides in the rack until the edge connector at the back 
of the card seats in the corresponding slot in the rack’s connector 
panel. Seating may require thumb pressure on the top and bottom 
of the card’s front panel.

CAUTION:

 

Take care not to press on any of the LEDs.

2.  Tighten the two thumb screws on the card until the front panel of 

the card is seated against the front of the rack.

WARNING

: Unit is to be used with a Listed Class 2 or LPS power supply rated 

9-12 VDC @ 1A.

IMPORTANT SAFEGUARDS: 
A)  Elevated Operating Ambient

 - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment may 
be greater than room ambient. Therefore, consideration should be given to 
installing the equipment in an environment compatible with the maximum 
ambient temperature (Tma) specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should be such 

that the amount of air flow required for safe operation of the equipment is 
not compromised.

MECHANICAL INSTALLATION INSTRUCTIONS

FIGURE A

Dimensions are for a standard ComNet™ three slot module

.313 [7.95 mm]

.156 [3.96 mm]

Содержание ValueLine FVT812

Страница 1: ...rdened and suitable for use in unconditioned roadside or out of plant installations The FVT FVR812 is compatible with NTSC PAL and SECAM video transmission protocols and supports bi directional RS232 422 and 485 2 4 Wire data See Figure 4 on Page 3 for data selection See Figure 6 on Page 5 for contact switch positions Bi Color LED indicators are provided to indicate the status of the system video ...

Страница 2: ...ts MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE FIGURE 2 FVT812 TRANSMITTER FIGURE 1 FVT FVR812 TRANSMITTER AND RECEIVER FIGURE 3 FVR812 RECEIVER INSTALLATION AND OPERATION MANUAL FVT FVR812 REAR PANEL REAR PANEL FRONT PANEL FRONT PANEL TECH SUPPORT 1 888 678 9427 ...

Страница 3: ...he front panel of the unit Switch 4 RS485 4 Wire 1 2 1 2 1 2 1 2 1 RS232 2 RS422 Bi Phase or Manchester 3 RS485 2 Wire Sensornet 1 RS232 DIN DOUT GND 2 RS422 Bi Phase Manchester DIN DIN DOUT DOUT GND 3 RS485 2 Wire Sensornet DIN DIN GND 4 RS485 4 Wire DIN DIN DOUT DOUT GND Termination Note A 120 ohm termination resistor is applied to the differential inputs when TERM is wired directly to DIN see d...

Страница 4: ...ta Out Data Out 2 Wire RS 485 Sensornet DIN DIN DIN DIN Data A Data B Data A Data B Data Transmit Data Receive Signal Ground DIN DOUT GND DOUT DIN GND Data Receive Data Transmit Signal Ground 4 Wire RS 485 DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out A Data Out B Data In A Data In B Data In A Data In B Data Out A Data Out B DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out Data Out Data In Data In Data...

Страница 5: ... down The four CONTACT switches on the front of the unit set the operating mode of the CONTACT OUT terminal pair It can either function as an alarm to indicate fault conditions or it can function as a contact closure to indicate the state of the CONTACT IN terminal pair on the rear of the unit at the other end of the fiber 1 2 3 4 ON OFF OFF OFF Closed when optical Port has established link Open w...

Страница 6: ...oriented right side up and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the front panel of the card is seated ...

Отзывы: