Step 1.

Unpack the mounting hardware from the box. Determine if this will be a pole or wall mount application.

The included Mounting kit is designed to support poles up to 2 in (5.8 cm) in diameter. If surface or wall mounting, the optional

NWBKT hardware will be required.

Step 3.

Slide the weather proof assembly over the cable so it can be 

screwed into the enclosure gland. Make sure the rubber sealing 

ring is in place as shown in step 3A.

Tighten the weather proof assembly into the enclosure and also 

tighten the cap that squeezes the rubber washer over the Ethernet 

cable as shown.

Step 2.

A.  Route the RJ45 connectorized Ethernet cable through the 

weather tight gland connection as shown at left.  

Note:  The slit rubber washer allows a pre-terminated 

Ethernet cable to be used. 

  

Once the cable has been routed through the weather 

connection as shown above, push the split rubber gasket 

into place and loosely screw the cap that goes over the 

rubber washer.

B.  Snap the RJ-45 connector in place as shown

A

A

B

B

C

Step 4.

A.   Connect one end of an RJ-45 Ethernet cable to the OUT 

port of the CNGE1IPS or other 35W PoE Injector (sold 

separately) and the other end to LAN of the access point. 

 

Maximum length of the RJ-45 CAT5 cable is 100 meters.* 

B.   Connect the RJ-45 Ethernet cable attached to the PoE 

Injector to a network device, such as to a switch or to the PC 

you will use to configure the access point.

C.   Connect the power adaptor to the main electrical supply 

and the power plug into the socket of the PoE Injector . 

 

PoE power input: Passive PoE (range 36 to 48 VDC). 

The NW10[E] can also be powered by a suitable IEEE 

802.3af/at PSE device such as a PoE switch or injector.

D.   A Drip Loop is recommended as additional precaution 

against moisture entering the Access Point housing.

*  Up to 200mW radio. For higher power radio upgrade to higher rating 

power adapter.

A

D

D

D

D

B

 

Ethernet 
Network

C

Network 

Edge Device

P1 

P2

Содержание NW10

Страница 1: ...e applies to the following models NW10 Industrial Multipoint FCC Version User Configurable An easy to read LED array displays unit operational status along with received signal strength ensuring optimal installation and operation See Figure 2 on Page 2 for LED Indicator explanations See Figures 3 through 5 beginning on Page 3 for mounting instructions This manual serves the following ComNet Model ...

Страница 2: ... is in reset LAN SOLID GREEN LAN Connected OFF No Connectivity RSSI1 SOLID RED Weak Connection RSSI2 SOLID ORANGE Moderate Connection RSSI3 SOLID GREEN Solid Connection RSSI4 SOLID GREEN Excellent Connection Advisable to check Status Page to confirm RSSI is 55 SIGNAL STRENGTH RSSI1 POWER RSSI2 POrt 2 LAN RSSI3 RSSI4 PORT 1 POE IN PORT 2 POE OUT IMPORTANT Only plug PoE power to Port 1 Connecting a ...

Страница 3: ...ted through the weather connection as shown above push the split rubber gasket into place and loosely screw the cap that goes over the rubber washer B Snap the RJ 45 connector in place as shown A A B B C Step 4 A Connect one end of an RJ 45 Ethernet cable to the OUT port of the CNGE1IPS or other 35W PoE Injector sold separately and the other end to LAN of the access point Maximum length of the RJ ...

Страница 4: ...PAGE 4 QUICK START USER GUIDE NW10 TECH SUPPORT 1 888 678 9427 Included Hardware Vertical Mount in 45º Position Vertical Mount in 45º Position FIGURE 4 POLE MOUNT INSTRUCTIONS ...

Страница 5: ...terfaces tab click on Edit in the LAN settings section to change the IP address of the device and set the desired network settings Hit Save Apply NOTE This will be the network address for the NetWave web server It is not necessary to set to the same subnet as the operating network but it is recommended 8 Select the NETWORK WIFI tab and set Wireless mode Set to AP or Client NOTE It is the user s re...

Страница 6: ...nal Strength is based on a number of factors including the output power of the radios antenna gain and the attenuation of the signal as it travels from the transmitter to the receiver Signal strength is expressed in dBm dBm is a power ratio in decibels dB referenced to 1mW Since most received signal levels are under 1mW negative values are typically displayed The more negative the number the weake...

Страница 7: ...d to Network CNGE1IPS or any PSE device IP Camera PoE Camera Power P1 P2 PoE 1Gbps Ethernet PoE Ethernet Ethernet PoE Ethernet PoE Camera PoE Camera NW10 Access Point NW10 Client ComNet Gigabit Managed Switch providing 30W PoE Connected to Network ComNet Gigabit Managed Switch providing 30W PoE P1 P1 PoE 1Gbps Ethernet PoE Ethernet PoE Ethernet PoE 1Gbps Ethernet PC NVR NW10 IA870 240 Mbps Access ...

Страница 8: ...will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the ...

Страница 9: ...F 44 0 113 253 7462 INFO EUROPE COMNET NET Need Additional Assistance Visit our website http www comnet net or contact Comnet tech support Tel 203 796 5300 Toll free 888 678 9427 Email techsupport comnet net Additional Technical support contact details can be found at http www comnet net services technical support html Or Visit our pre sales design center http www comnet net services design center...

Отзывы: