background image

INS_NW8_NW8E_QS_REV–   05/20/13   PAGE 5

QUICK START USER GUIDE 

NW8/NW8E

TECH SUPPORT: 1.888.678.9427

FIGURE 6 – OPTIONAL POLE/WALL MOUNT HARDWARE

ComNet Part NWBKT1

INSTALLATION REQUIREMENTS

CONFIGURING NETWAVE

Shielded outdoor CAT 5 or better should be used for all out of plant Ethernet connection and should be properly grounded 
through the PoE AC ground. Industrial grade shielded Ethernet cable is recommended to help prevent ESD damage commonly 
experienced with outdoor installations. Visit www.comnet.net/comnet-products/cables

1.  Connect an Ethernet cable from the port labelled as IN on the power Injection Module to either a laptop or a PC LAN port.

2.  Connect the second Ethernet cable from the OUT port on the Power Injection Module to the NetWave port 1. 

3.  Apply mains power 90 – 240 VAC to the Power Injection Module with the provided power cord. You should notice the green 

LED illuminate in the Power Injection Module and the power LED on the NetWave unit.

4.  Set the IP address of the laptop being used to configure NetWave to static and the subnet to 192.168.10.x/24 subnet.

5.  Point the browser to 192.168.10.102. This is the default address.

6.  A login prompt will pop up. Enter: 

ID: 

admin

 

 

Password: 

admin

7.  Select the NETWORK SETTINGS tab and set the desired network settings. 

Select Apply Settings 
Select Save 
NOTE:  This will be the network address for the NetWave web server. It is not necessary to set to the same subnet as the 

operating network but it is recommended.

8  Select the WIRELESS SETTINGS tab and set: 

• Wireless mode – Set to AP or Client 
• Country code – Only required if setting up the NW8E (ETSI) model 
NOTE:  It is the user’s responsibility to ensure that the correct country is chosen. ComNet accepts no liability for incorrectly set 

up equipment. 

• Output RF power – if RSSI is greater than 70, it is recommended to reduce RF TX power at the connected remote node.

• Set SSID – if changing from the default setting

•  Channel Spectrum Width – May want to reduce to 20M (or 10M) from the default 20/40M if the 5GHz spectrum is crowded or 

connections across the link are unstable.

• Wireless Security – if changing from default settings

• Select Apply Settings

• Select Save

Содержание NetWave NW8

Страница 1: ...ng models NW8 Industrial Multipoint FCC Version User Configurable NW8E Industrial Multipoint ETSI Version User Configurable An easy to read LED array displays unit operational status along with receiv...

Страница 2: ...ed to the NW8 NW8E ETHERNET RSSI2 FLASH GREEN Ethernet connection is established SOLID YELLOW Ethernet connection is established and there is activity present RSSI Level is Yellow LED Threshold OFF No...

Страница 3: ...the split rubber gasket into place and loosely screw the cap that goes over the rubber washer B Snap the RJ 45 connector in place as shown A B Step 4 A Connect one end of an RJ 45 Ethernet cable to t...

Страница 4: ...sition Vertical Mount in 45 Position FIGURE 5 POLE MOUNT INSTRUCTIONS Step 1 Determine the correct cable type and length needed to connect the NetWave device to your antenna antenna and cables not inc...

Страница 5: ...dress of the laptop being used to configure NetWave to static and the subnet to 192 168 10 x 24 subnet 5 Point the browser to 192 168 10 102 This is the default address 6 A login prompt will pop up En...

Страница 6: ...al Directional Antenna NW8 NW8 NWADA1 External Directional Antenna PoE Camera NW8 NWADA1 External Directional Antenna PoE Camera ComNet Gigabit Managed Switch providing 30W PoE NWADA1 External Directi...

Страница 7: ...0M Long Range Parameters Enabled and defaulted to 1000m STP Disabled NOTE A Reset to defaults performed on the ADMIN page will erase all user configurations TYPICAL DROP AND REPEAT TOPOLOGY APPLICATIO...

Страница 8: ...qui est n cessaire pour une communication r ussie Cet appareil est conforme la norme RSS Industrie Canada exempts de licence norme s Son fonctionnement est soumis aux deux conditions suivantes 17 Comp...

Страница 9: ...44 0 113 253 7462 INFO EUROPE COMNET NET Need Additional Assistance Visit our website http www comnet net or contact Comnet tech support Tel 203 796 5300 Toll free 888 678 9427 Email techsupport comn...

Отзывы: