Comnet FVT8014 Скачать руководство пользователя страница 5

INS_FVT/FVR8014_REV–

05/10/10

PAGE 5

FIGURE 7 – DATA CONNECTIONS

See Page 4 for Switch Settings

RS232

Customer

Equipment

FVT8014

Customer

Equipment

FVR8014

RS422

Bi-phase or

Manchester

DOUT(+)

DOUT(-)

DIN(+)

DIN(-)

Data In (+)

Data In (-)

Data Out (+)

Data Out (-)

2-Wire

RS485,

Sensornet

DIN(+)

DIN(-)

DIN(+)

DIN(-)

Data (A)

Data (B)

Data (A)

Data (B)

Data Transmit

Data Receive

Signal Ground

DIN(-)

DOUT(-)

GND

DOUT(-)

DIN(-)

GND

Data Receive

Data Transmit

Signal Ground

4-Wire

RS485

DIN(+)

DIN(-)

DOUT(+)

DOUT(-)

DOUT(+)

DOUT(-)

DIN(+)

DIN(-)

Data Out (A)

Data Out (B)

Data In (A)

Data In (B)

Data In (A)

Data In (B)

Data Out (A)

Data Out (B)

DIN(+)

DIN(-)

DOUT(+)

DOUT(-)

DOUT(+)

DOUT(-)

DIN(+)

DIN(-)

Data Out (+)

Data Out (-)

Data In (+)

Data In (-)

Data In (+)

Data In (-)

Data Out (+)

Data Out (-)

FIGURE 8 – LED INDICATORS

 LINK 

VIDEO 

DATA 

 

POWER

GREEN 

Communication link has 

An active video signal is  An active data signal is  

Unit powered up

 

been established over 

present on the BNC  

present on the input pins  

 

optical fiber 

connector. 

of the data connector. 

RED 

Communication link has   No video signal 

– 

 

 

not been established. 

OFF 

Not powered up correctly  – 

No data signal 

Unit powered down

TECH SUPPORT: 1.888.678.9427

INSTALLATION AND OPERATION MANUAL 

FVT/FVR8014

Отзывы: