Mechanical Installation Instructions 

Figure 1–

 Dimensions are for a standard ComNet

™ 

one slot module.

Rack Module:

The unit is designed to be installed in the ComNet 19-inch (483-mm) EIA standard card-cage rack, the C1-US, 
C1-EU, or the C1-CH. Follow these guidelines to install rack cards after performing  module setup procedures.

C1-US, C1-EU, or the C1-CH Card Cage Racks

CAUTION: 

Although the units are hot-swappable and may be installed without turning power off to the rack, ComNet 

recommends that the power supply be turned off and that the rack power supply is disconnected from any power 
source. 

Note:

 Remove electrical connector before installing in card cage rack.

1.  Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge 

connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may 
require thumb pressure on the top and bottom of the card’s front panel.

CAUTION: Take care not to press on any of the LEDs.

2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.

FVT/FVR401

Installation Considerations

This fiber-optic link is supplied as a 
Standalone/Rack module. Units should be 
installed in dry locations protected from 
extremes of temperature and humidity.

Standalone Module:

The unit is provided with a mounting 
plate with holes for two No. 6 pan head 
screws (3-mm or 3.55-mm). 

Attach the module to a solid piece of 
wood using two No. 6 pan head wood 
screws with a minimum penetration 
into the wood of 3/4 inch. (Screws not 
supplied) See figure 1.

1.  Determine where the module will 

be installed, and ensure that there 
is adequate space at both ends for 
making the various cable connections 
and for reading the diagnostic LEDs.

2.  Attach the module to a flat surface 

using two mounting screws.

.156 [3.96 mm]

.313 [7.95 mm]

INS_FVT/FVR401_REV–

06/09/09

Page 1