INS_FVTFVR109B/Bosch_REV–
08/16/11
PAGE 2
FIGURE 1 – FVT109B(M,S)1ID/Bosch
TRANSMITTER
INSTALLATION AND OPERATION MANUAL
FVT/FVR109B(M,S)1[ID]/BOSch
TEch SUPPORT: 1.888.678.9427
CONNECTIONS FOR BOSCH
CAMERA FIBER MODULE:
IN-DOME VIDEO TRANSMITTER MODULE
(FVT109B(M,S)1ID/Bosch / PCA1144):
1. Connect power and data from the camera to the module:
Attach to module at J5 (8-pin male connector with white
plastic shroud) with Bosch’s 5-pin to 8-pin cable assembly.
Video LED D1 should illuminate red.
Data LED D2 should stay off.
Link LED D3 should illuminate red.
2. Connect video from camera to module:
Attach to module at J4 (2-pin male connector with white
plastic backing) with ComNet’s 2-pin to BNC cable.
Video LED D1 should illuminate green.
3. Connect fiber to module:
Attach single-mode fiber to U11 (single SC fiber optic con-
nector). Link LED should illuminate green once receiver is
powered on and link is established over the fiber.
4. Attach module to Bosch’s metal camera insert with white
plastic stand-offs.
Stand-offs snap into the three gold mounting holes in the module.
Secure the insert and attached module in camera with screws.
NOTE: Data LED D2 will flash green when Bosch Bi-phase data is received.
EXTERNAL VIDEO RECEIVER MODULE (FVR109B(M,S)1/Bosch):
1. Connect power to module:
Use +9 VDC adapter included with module, or insert into ComNet rack.
POWER LED should illuminate green.
LINK LED should illuminate red.
VIDEO LED should illuminate red.
DATA LED should stay off.
2. Connect video output to monitor:
Attach to BNC connector labeled VIDEO OUT
3. Connect fiber to module:
Attach single-mode fiber to SC fiber optic connector labeled OPTICAL.
4. If Bi-phase data is used to control the camera then connect data to screw terminal block on module:
Bi-phase CODE+ should be connected to DIN+.
Bi-phase CODE- should be connected to DIN-.
Shield should be connected to GND.
NOTE: LINK LED will illuminate green once a link is established over optical fiber with the In-Dome Transmitter module.
VIDEO LED will illuminate green when active signal is detected at the BNC.
DATA LED will flash green when Bi-phase commands are detected at the data connector.
MULTIMODE OR
SINGLE MODE
OPTICAL FIBER