Comnet FVR10D2I1C4E Скачать руководство пользователя страница 7

INS_FVT/FVR20D2I1C4E_REV-   06/22/12  PAGE 7

TECH SUPPORT: 1.888.678.9427

INSTALLATION AND OPERATION MANUAL 

FVT/FVR20D2I1C4E

FVT10D2I1C4E

FVT10D2I1C4E

Form ‘C’ Relay 
Output

LE-D

FVR10D2I1C4E

Door/Barrier 

Contact Input

LEF

FVR10D2I1C4E

10/1

00

ETHE

RNET

FIGURE 10 – SFP CONNECTIONS

Number of fibers and type of fiber connectors will be determined by selected SFP modules and if point-to-point or redundant modes are required.

FIGURE 11 – AIPHONE

 INTERCOM CONNECTIONS

The units are designed to operate with the Aiphone

 LE-D and LEF intercom system.

PIN # Wire Color Aiphone Connections

1

Blue

LEF ‘E’ TERMINAL

2

Orange

LEF ‘1’ TERMINAL

3

Black

LEF ‘–’ TERMINAL

4

Red

NC

5

Green

CONTACT INPUT +

6

Yellow

NC

7

Brown

GND

8

White

GND

PIN # Wire Color Aiphone Connections

1

Blue

LE-D ‘-’ TERMINAL

2

Orange

LE-D ‘1’ TERMINAL

3

Black

LE-D ‘E’ TERMINAL

4

Red

RELAY OUTPUT COM

5

Green

RELAY OUTPUT N.C.

6

Yellow

RELAY OUTPUT N.O.

7

Brown

GND

8

White

GND

3

3

E

2

1

2

1

1

E

5

5

4

7

6

1

Содержание FVR10D2I1C4E

Страница 1: ... with tamper supervision in addition to one 10 100Mb Ethernet channel The ComNet FVT FVR10D2I1C4E has dual optical SFP ports to provide a redundant point to point fail safe topology in the event of loss of one fiber or one optical module Operational status can be monitored by using the web management interface through the addition of the ComNet network managed chassis and network management interf...

Страница 2: ...er determined by Selection of Small Form factor Pluggable SFP modules FIGURE 3 FVR10D2I1C4E RECEIVER REAR PANEL REAR PANEL FRONT PANEL FRONT PANEL BLACK BLACK W WHITE STRIPE Power Supply Dual 8 24VDC 4W Rack Mount C2 Network Managed NOTE Remove PWR1 Electrical Connector for Rack Mount Units BLACK BLACK W WHITE STRIPE One SFP required for point to point operation Two SFPs required for redundant ope...

Страница 3: ... Color Aiphone Connections 1 Blue LE D TERMINAL 2 Orange LE D 1 TERMINAL 3 Black LE D E TERMINAL 4 Red RELAY OUTPUT COM 5 Green RELAY OUTPUT N C 6 Yellow RELAY OUTPUT N O 7 Brown GND 8 White GND PIN Wire Color Data Connections 1 Blue DATA OUT 2 Orange DATA OUT 3 Black DATA IN 4 Red RELAY OUT 5 Green RELAY OUT 6 Yellow DATA IN 7 Brown GND 8 White 5V BIAS VIEW INSIDE RJ 45 PORT RJ 45 PORTS Located o...

Страница 4: ...IN Wire Color Aiphone Connections 1 Blue LEF E TERMINAL 2 Orange LEF 1 TERMINAL 3 Black LEF TERMINAL 4 Red NC 5 Green CONTACT INPUT 6 Yellow NC 7 Brown GND 8 White GND PIN Wire Color Data Connections 1 Blue DATA OUT 2 Orange DATA OUT 3 Black DATA IN 4 Red RELAY OUT 5 Green RELAY OUT 6 Yellow DATA IN 7 Brown GND 8 White 5V BIAS VIEW INSIDE RJ 45 PORT RJ 45 PORTS Located on Rear Panel RJ 45 BREAK OU...

Страница 5: ...NC RS422 INPUT RS485 INPUT RS485 INPUT 4 RELAY OUT RELAY OUT RELAY OUT RELAY OUT 5 RELAY OUT RELAY OUT RELAY OUT RELAY OUT 6 RS232 INPUT RS422 INPUT RS485 INPUT RS485 INPUT 7 GND GND GND GND 8 5V BIAS 5V BIAS 5V BIAS 5V BIAS FIGURE 6 DATA SWITCH POSITIONS The mode for each data channel is configured using a set of two switches labeled DATA1 S3 and DATA2 S4 located on the front panel of the unit FI...

Страница 6: ...nal Ground DIN DOUT GND DOUT DIN GND Data Receive Data Transmit Signal Ground 4 Wire RS485 DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out A Data Out B Data In A Data In B Data In A Data In B Data Out A Data Out B DIN DIN DOUT DOUT DOUT DOUT DIN DIN Data Out Data Out Data In Data In Data In Data In Data Out Data Out FIGURE 9 POSSIBLE ETHERNET CONFIGURATION Ethernet IEEE 802 3 Network Element Ethernet...

Страница 7: ...point to point or redundant modes are required FIGURE 11 AIPHONE INTERCOM CONNECTIONS The units are designed to operate with the Aiphone LE D and LEF intercom system PIN Wire Color Aiphone Connections 1 Blue LEF E TERMINAL 2 Orange LEF 1 TERMINAL 3 Black LEF TERMINAL 4 Red NC 5 Green CONTACT INPUT 6 Yellow NC 7 Brown GND 8 White GND PIN Wire Color Aiphone Connections 1 Blue LE D TERMINAL 2 Orange ...

Страница 8: ... is connected in series with the contact closure input and a 1K resistor is connected in parallel across the contact closure input Both open circuits and short circuits can be detected as well as normal opens and closes ON OFF Series Supervision When a 1K resister is connected in series with the contact closure input In this mode shorts across the contact inputs can be detected but open circuits c...

Страница 9: ...Failure ON OFF Alarm 1 SFP 1 or SFP 2 Failure Alarm 2 Video Loss OFF ON Alarm 1 SFP 1 Failure or Video Loss Alarm 2 SFP 2 Failure or Video Loss OFF OFF Alarm 1 SFP 1 or SFP 2 Failure or Video Loss Alarm 2 SFP 1 or SFP 2 Failure or Video Loss OFF RED GREEN FLASHING SFP SFP not installed No optical link Link is good and is in use Link is good but is not in use VIDEO No video signal An active video s...

Страница 10: ...ard is oriented right side up and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take care not to press on any of the LEDs 2 Tighten the two thumb screws on the card until the front panel of the card is ...

Отзывы: