INSTALLATION CONSIDERATIONS 

This fiber-optic link is supplied as a Standalone/Rack module. Units should 

be installed in dry locations protected from extremes of temperature and 

humidity.

C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION:

 Although the units are hot-swappable and may be installed 

without turning power off to the rack, ComNet recommends that the 

power supply be turned off and that the rack power supply is disconnected 

from any power source. 

Note:

 Remove electrical connector before 

installing in card cage rack.
1.  Make sure that the card is oriented right side up, and slide it into the 

card guides in the rack until the edge connector at the back of the card 

seats in the corresponding slot in the rack’s connector panel. Seating 

may require thumb pressure on the top and bottom of the card’s front 

panel.

CAUTION:

 

Take care not to press on any of the LEDs.

2.  Tighten the two thumb screws on the card until the front panel of the 

card is seated against the front of the rack.

WARNING

: Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS: 
A)  Elevated Operating Ambient

 - If installed in a closed or multi-

unit rack assembly, the operating ambient temperature of the 

rack environment may be greater than room ambient. Therefore, 

consideration should be given to installing the equipment in an 

environment compatible with the maximum ambient temperature 

(Tma) specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should 

be such that the amount of air flow required for safe operation of the 

equipment is not compromised.

FIGURE 7 – LED INDICATORS

LINK

VIDEO

CONTACT*

GREEN

Communication link has been 

established over optical fiber

Video signal is present on the 

channel.

Contact input is closed.

RED

Communication link has not 

been established.

Video signal is not present on the 

channel.

OFF

Unit powered down.

Unit powered down.

Contact input is open.

*  Contact Closure channels are not operational when used with the FVT1(M,S)1/M transmitters.