INS_F(T,R)A2C1(M,S)1_FXA2C1(M,S)1_REV–   04/25/12   PAGE 5

Tech SupporT: 1.888.678.9427

INSTALLATION AND OPERATION MANUAL 

FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1

FIGURE 9 – LED INDICATORS

INSTALLATION AND OPERATION MANUAL 

FTA/FRA2C1(M,S)1 AND FXA2C1(M,S)1

FIGURE 7 – AUDIO WIRING

Wiring panel terminal block is located on the back panel of each unit.

FIGURE 8 – CONTACT WIRING

Wiring panel terminal block is located on the back panel of each unit.

Contact Closure 

Output

Channel 1   

Signal In from 

Customer Equipment

Channel 1   

Signal Out to  

Customer Equipment

Channel 2  

Signal In from 

Customer Equipment

Channel 2  

Signal Out to  

Customer Equipment

Contact Closure Input 

(Dry Contacts Only)

Audio Input 

(Receiver/Transceiver)

Contact Out  

(Receiver/Transceiver)

Audio Output

(Transmitter/Transceiver)

Contact In

(Transmitter/Transceiver)

LINK

AUDIO

CONTACT

IN

ouT

IN

ouT

RED

Communication link has 
not been established over 
fiber

_

_

Contact closure input is 
open

Contact closure output 
is open

GRN

Communication link has 
been established over 
fiber

lEd intensity varies with 
audio signal level of either 
channel input

lEd intensity varies with 
audio signal level of either 
channel output

Contact closure input is 
closed

Contact closure output is 
closed

OFF

unit powered down

low or no audio input 
level

low or no audio outnput 
level

unit powered down

Отзывы: