MECHANICAL INSTALLATION INSTRUCTIONS

FIGURE A

Dimensions are for a ComNet

 small size module

FIGURE B

Dimensions are for a standard ComNet™ one slot module

.156 [3.96 mm]

.313 [7.95 mm]

INSTALLATION CONSIDERATIONS 

This fiber-optic link is supplied as a Standalone/Rack module. Units should 

be installed in dry locations protected from extremes of temperature and 

humidity.

C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS
CAUTION:

 Although the units are hot-swappable and may be installed 

without turning power off to the rack, ComNet recommends that the power 

supply be turned off and that the rack power supply is disconnected from 

any power source. Note: Remove electrical connector before installing in 

card cage rack.
1.  Make sure that the card is oriented right side up, and slide it into the 

card guides in the rack until the edge connector at the back of the card 

seats in the corresponding slot in the rack’s connector panel. Seating 

may require thumb pressure on the top and bottom of the card’s front 

panel.

CAUTION:

 Take care not to press on any of the LEDs.

2.  Tighten the two thumb screws on the card until the front panel of the 

card is seated against the front of the rack.

WARNING: 

Unit is to be used with a Listed Class 2 power supply.

IMPORTANT SAFEGUARDS:

 

A)  Elevated Operating Ambient - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment 

may be greater than room ambient. Therefore, consideration should 

be given to installing the equipment in an environment compatible 

with the maximum ambient temperature (Tma) specified by the 

manufacturer.

B)  Reduced Air Flow - Installation of the equipment in a rack should 

be such that the amount of air flow required for safe operation of the 

equipment is not compromised.

Содержание CNMC SFP Series

Страница 1: ...put back to the 10 100 1000 Mbps electrical output Auto Negotiating is supported on the copper interface side Connect SFP VDSL devices using a twisted 2 wire cable Refer to connection paragraph for details The series consists of a small size single channel model CNMCSFP MV and a ComFit standard size dual channel model CNMC2SFP V The CNMC2SFP V media converters are designed specially for the VDSL S...

Страница 2: ...LLATION AND OPERATION MANUAL CNMC 2 SFP M V Series CAT5e 6 BLACK BLACK WITH WHITE STRIPE Surface Mount Power 9 24 VDC 2 5 W max OR 24 VAC 2 5 W max FIGURE 1 CNMCSFP MV SMALL SIZE UNIT FIGURE 2 CNMCSFP MV SMALL SIZE UNIT REAR PANEL FRONT PANEL SFP VDSLA or SFP VDSLB ...

Страница 3: ...NUAL CNMC 2 SFP M V Series CAT5e 6 CAT5e 6 FIGURE 3 CNMC2SFP V COMFIT UNIT FIGURE 4 CNMC2SFP V COMFIT UNIT REAR PANEL FRONT PANEL SFP VDSLA or SFP VDSLB SFP VDSLA or SFP VDSLB BLACK BLACK WITH WHITE STRIPE Surface Mount Power 9 24 VDC 5 W max OR 24 VAC 5 W max Rack power Supplied by Rack ...

Страница 4: ...fications FIGURE 7 BANDWIDTH VS DISTANCE INSTALLATION OPERATION Interface Type 1000BaseFX Connector SFP MSA Compliant Connectors RJ 45 Data Rate Up to 150 Mbps Power Operating Voltage 12 V Power Consumption 3 W Max Mechanical LED Indicators Power Link Status on side of SFP module Dimensions H x W x L 0 54 0 67 3 12 in 13 7 17 0 79 2 mm Weight 1 13 oz 32 0 g Environmental Operating Temp 40 C to 75 ...

Страница 5: ...at the rack power supply is disconnected from any power source Note Remove electrical connector before installing in card cage rack 1 Make sure that the card is oriented right side up and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of...

Отзывы: