INS_CNGE11FX3TX8MS[POE][HO] Rev. 11.6.17 PAGE 237
INSTRUCTION MANUAL
CNGE11FX3TX8MS[POE][HO]
TECH SUPPORT: 1.888.678.9427
PHYtest
Press “Start” to run the diagnostics. This will take approximately 5 seconds. If all ports are
selected, this can take approximately 15 seconds. When completed, the page refreshes
automatically, and you can view the cable diagnostics results in the cable status table. Note that
VeriPHY is only accurate for cables of length 7 - 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY
on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is
complete.
Object
Description
Port
The port where you are requesting VeriPHY Cable Diagnostics.
Cable Status
Port:
Port number.
Pair:
The status of the cable pair.
OK - Correctly terminated pair
Short - Shorted pair
Short A - Cross-pair short to pair A
Short B - Cross-pair short to pair B
Short C - Cross-pair short to pair C
Short D - Cross-pair short to pair D
Cross A - Abnormal cross-pair coupling with pair A
Cross B - Abnormal cross-pair coupling with pair B
Cross C - Abnormal cross-pair coupling with pair C
Cross D - Abnormal cross-pair coupling with pair D
Length:
The length (in meters) of the cable pair. The resolution is 3 meters
Click “Start” button to start the cable diagnostic test.