INS_CNFE2MCPOE[/M]_REV–

07/28/10

PAGE 4

TECH SUPPORT: 1.888.678.9427

INSTALLATION AND OPERATION MANUAL 

CNFE2MCPOE[/M]

FIGURE 7 – POSSIBLE ETHERNET CONFIGURATION

Ethernet IEEE 802.3 

Network Element

Ethernet IEEE 802.3 

Network Element

CNFE2MCPOEA

CNFE2MCPOEB

CAT5e/6 with

RJ45 Connections  

100m (328ft)

CAT5e/6 with

RJ45 Connections 

100m (328ft)

Optical Fiber 

Determined By 

Selection Of SFP 

Module

Ethernet IEEE 802.3 Network Element determined by user.

FIGURE 5 – LED INDICATORS

FIGURE 6 – SWITCH POSITIONS 

 

Power over Ethernet is controlled by a switch based on fiber link.

LINK

PSE1 or PSE2

POWER

GREEN

Fiber interface linked 

(when lit or flashing)

Power is being sup-

plied by unit

Unit powered up

OFF

Fiber interface not 

linked.

Power not supplied 

by unit.  

(No PoE device)

Unit powered down

SWITCH

LINK

PSE1 / PSE2

ON

Yes (On or Flash)

ON

No (off)

OFF

OFF

ON

Содержание CNFE2MCPOE

Страница 1: ...lso supports IEEE 802 3at as Power Sourcing Equipment PSE with up to 30 Watts output both Mode A or Mode B are supported The electrical interface will Auto Negotiate to a 10 Mbps or 100 Mbps Ethernet rate without any adjustments The optical interface operates at a 100 Mbps Ethernet rate It is environmentally hardened to operate in extreme conditions LED indicators are provided for confirming equip...

Страница 2: ...AT5e 6 BLACK BLACK WITH WHITE STRIPE Power 12VDC 3A 24VDC 1 5A NOTE Remove Electrical Connector for Rack Mount Units PoE is not supported when mounted within ComNet rack FIGURE 2 CNFE2MCPOE MEDIA CONVERTER FIGURE 1 CNFE2MCPOE MEDIA CONVERTER REAR PANEL FRONT PANEL OPTICAL FIBER DETERMINED BY SELECTION OF SFP MODULE ...

Страница 3: ...427 INSTALLATION AND OPERATION MANUAL CNFE2MCPOE M BLACK BLACK WITH WHITE STRIPE Power 12VDC 3A 24VDC 1 5A CAT5e 6 FIGURE 4 CNFE2MCPOEM MEDIA CONVERTER FIGURE 3 CNFE2MCPOEM MEDIA CONVERTER REAR PANEL FRONT PANEL OPTICAL FIBER DETERMINED BY SELECTION OF SFP MODULE ...

Страница 4: ...ctions 100m 328ft Optical Fiber Determined By Selection Of SFP Module Ethernet IEEE 802 3 Network Element determined by user FIGURE 5 LED INDICATORS FIGURE 6 SWITCH POSITIONS Power over Ethernet is controlled by a switch based on fiber link LINK PSE1 or PSE2 POWER GREEN Fiber interface linked when lit or flashing Power is being sup plied by unit Unit powered up OFF Fiber interface not linked Power...

Страница 5: ...INS_CNFE2MCPOE M _REV 07 28 10 PAGE 5 TECH SUPPORT 1 888 678 9427 INSTALLATION AND OPERATION MANUAL CNFE2MCPOE M ...

Страница 6: ... a Surface mount module Units should be installed in dry locations protected from extremes of temperature and humidity WARNING Unit is to be used with a Listed Class 2 power supply IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration s...

Отзывы: