INS_CNFE1EOC-M_REV–

04/09/10

PAGE 3

FIGURE 3 – POSSIBLE ETHERNET CONFIGURATIONS

Ethernet IEEE 802.3 

Network Element

Ethernet IEEE 802.3 

Network Element

Ethernet IEEE 802.3 

Network Element

Ethernet IEEE 802.3 

Network Element

CNFE1EOC-M 

(Master*)

CNFE1EOC-M

(Master*)

CNFE1EOC-M

(Remote)

CNFE1EOC-M

(Remote)

CAT5e/6 with

RJ45 Connections 

100m (328ft)

CAT5e/6 with

RJ45 Connections

100m (328ft)

CAT5e/6 with

RJ45 Connections

100m (328ft)

CAT5e/6 with

RJ45 Connections 

100m (328ft)

Coaxial (75

Ω

)

Copper Pair

Ethernet IEEE 802.3 Network Element determined by user.

No Connection

No Connection

OR

* Master unit located at video source.

TECH SUPPORT: 1.888.678.9427

Содержание CNFE1EOC-M

Страница 1: ...pgrading of a legacy twisted copper or coaxial cable plant for use with Ethernet rather than installing new network cabling The fastest usable data rate is automatically selected depending upon the transmission distance and cable quality The CNFE1EOC M may be deployed in most out of plant installations such as those found in intelligent transportation systems and factory automation control applica...

Страница 2: ...GE 2 COAX 75Ω COPPER PAIR CAT5e 6 BLACK BLACK WITH WHITE STRIPE FIGURE 1 CNFE1EOC M SMALL SIZE UNIT FIGURE 2 CNFE1EOC M SMALL SIZE UNIT INSTALLATION AND OPERATION MANUAL CNFE1EOC M REAR PANEL FRONT PANEL TECH SUPPORT 1 888 678 9427 ...

Страница 3: ...lement CNFE1EOC M Master CNFE1EOC M Master CNFE1EOC M Remote CNFE1EOC M Remote CAT5e 6 with RJ45 Connections 100m 328ft CAT5e 6 with RJ45 Connections 100m 328ft CAT5e 6 with RJ45 Connections 100m 328ft CAT5e 6 with RJ45 Connections 100m 328ft Coaxial 75Ω Copper Pair Ethernet IEEE 802 3 Network Element determined by user No Connection No Connection OR Master unit located at video source TECH SUPPOR...

Страница 4: ...ror Correction Off Forward Error Correction On 3 Asymmetrical Data Symmetrical Data 4 Long Reach 1000ft 305m Short Reach 1000ft 305m CNFE1EOC M LINE STATUS RED MASTER or GRN REMOTE POWER GREEN Line side activity Remote Configuration Unit powered up RED Master Configuration OFF No activity Unit powered down TECH SUPPORT 1 888 678 9427 ...

Страница 5: ...LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 INFO EUROPE COMNET NET MECHANICAL INSTALLATION INSTRUCTIONS INSTALLATION CONSIDERATIONS This fiber optic link is supplied as a Standalone module The unit is provided with a mounting plate with holes for two No 6 pan head screws 3mm or 3 55mm See Figure A Units should be installed in dry locations protected from extremes of temperature and humidity N...

Отзывы: