MECHANICAL INSTALLATION INSTRUCTIONS

FIGURE A

Dimensions are for a standard ComNet™ one slot module

.156 [3.96 mm]

.313 [7.95 mm]

INSTALLATION CONSIDERATIONS 

This fiber-optic link is supplied as a Standalone/Rack module. Units 
should be installed in dry locations protected from extremes of 
temperature and humidity.

C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS

CAUTION:

 Although the units are hot-swappable and may be installed 

without turning power off to the rack, ComNet recommends that 
the power supply be turned off and that the rack power supply 
is disconnected from any power source. 

Note:

 Remove electrical 

connector before installing in card cage rack.

1.  Make sure that the card is oriented right side up, and slide it into 

the card guides in the rack until the edge connector at the back 
of the card seats in the corresponding slot in the rack’s connector 
panel. Seating may require thumb pressure on the top and bottom 
of the card’s front panel.

CAUTION:

 

Take care not to press on any of the LEDs.

2.  Tighten the two thumb screws on the card until the front panel of 

the card is seated against the front of the rack.

WARNING

: Unit is to be used with a Listed Class 2 or LPS power supply rated 

9-12 VDC @ 1A.

IMPORTANT SAFEGUARDS: 
A)  Elevated Operating Ambient

 - If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment may 
be greater than room ambient. Therefore, consideration should be given to 
installing the equipment in an environment compatible with the maximum 
ambient temperature (Tma) specified by the manufacturer.

B)  Reduced Air Flow

 - Installation of the equipment in a rack should be such 

that the amount of air flow required for safe operation of the equipment is 
not compromised.

Содержание CNFE1CL1MC

Страница 1: ...or use with Ethernet rather than installing new network cabling The fastest usable data rate is automatically selected depending upon the transmission distance and cable quality The CNFECL1MC M may be deployed in most out of plant installations such as those found in intelligent transportation systems and factory automation control applications LED status indicators are provided for rapidly ascert...

Страница 2: ...onnector for Rack Mount Units COAX 75Ω COPPER PAIR CAT5e 6 BLACK BLACK WITH WHITE STRIPE FIGURE 2 CNFE1CL1MC STANDARD SIZE UNIT FIGURE 1 CNFE1CL1MC STANDARD SIZE UNIT INSTALLATION AND OPERATION MANUAL CNFE1CL1MC M REAR PANEL FRONT PANEL TECH SUPPORT 1 888 678 9427 ...

Страница 3: ...E 3 COAX 75Ω COPPER PAIR CAT5e 6 BLACK BLACK WITH WHITE STRIPE FIGURE 3 CNFE1CL1MC M SMALL SIZE UNIT FIGURE 4 CNFE1CL1MC M SMALL SIZE UNIT INSTALLATION AND OPERATION MANUAL CNFE1CL1MC M REAR PANEL FRONT PANEL TECH SUPPORT 1 888 678 9427 ...

Страница 4: ...45 Connections 100m 328ft Coaxial 75Ω Copper Pair Ethernet IEEE 802 3 Network Element determined by user No Connection No Connection OR Master unit located at video source Line Side Port 2 Coax connector BNC Impedance 75 ohm coax Throughput Down Stream Up Stream 250 ft 76 m 91 Mbps 84 Mbps 500 ft 152 m 86 Mbps 82 Mbps 1000 ft 305 m 65 Mbps 69 Mbps 1500 ft 457 m 40 Mbps 52 Mbps Line Side Port 1 UTP...

Страница 5: ...ical Data Symmetrical Data ON 4 Long Reach 1000ft 305m Short Reach 1000ft 305m ON LINE STATUS STAT RED MASTER M RD or GRN REMOTE R GN POWER GREEN Line side activity Remote Configuration Unit powered up RED Master Configuration OFF No activity Unit powered down LED STATUS Low Constant Flashing Fast Constant Flashing On Intermittent Flashing UNIT STATUS Idle Line Is Not Connected Master Remote Negot...

Страница 6: ...cted from any power source Note Remove electrical connector before installing in card cage rack 1 Make sure that the card is oriented right side up and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel Seating may require thumb pressure on the top and bottom of the card s front panel CAUTION Take...

Отзывы: