background image

INS_CLFE4US1TPC_REV–

10/11/11

PAGE 4

© 2012 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC. 

3 CORPORATE DRIVE | DANBURY, CT 06810 | USA 

T: 203.796.5300 | F: 203.796.5303 | TECh SUPPORT: 1.888.678.9427 | [email protected]

8 TURNBERRY PARk ROAD | GILDERSOME | MORLEY | LEEDS, Uk LS27 7LE

T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | [email protected]

MEChANICAL INSTALLATION INSTRUCTIONS

•  Read and keep these directions.
•  heed all warnings.
•  Follow all instructions.
•  do not use this apparatus near water.
•  Clean only with a dry cloth.
•  Install in accordance with the manufacturer’s instructions.
•  This installation should be made by a qualified service person and should 

conform to all local codes.

•  DO NOT bundle UTP or Coax signals in the same conduit as high-voltage 

wiring.

•  To reduce the risk of fire or electrical shock, do not expose these products 

to rain, moisture, dripping or splashing.

•  No  objects  filled  with  liquids,  such  as  vases,  shall  be  placed  on  the 

equipment.

•  DO  NOT  install  the  unit  in  a  place  where  the  operating  ambient 

temperature exceeds 75ºC.

•  Make  sure  that  the  external  power  supply  output  voltage  is  in  the 

recommended range.

•  Do not install near any heat sources such as radiators, heat registers, stoves 

or other apparatus (including dVRs) that produce heat.

•  Protect the power cord from being walked on or pinched, particularly at 

the power source, convenience receptacles and the point where they exit 

from the apparatus.

•  only use attachments/accessories specified by the manufacturer.
•  Unplug this apparatus during lightning storms or when unused for long 

periods of time.

•  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is  required 

when the apparatus has been damaged in any way, such as when a power 

supply cord or plug is damaged, liquid has been spilled, objects have 

fallen inside the apparatus, the apparatus has been exposed to rain or 

moisture, do not operate normally or has been dropped.

•  The main plus is used as the disconnect device and shall remain readily 

operable.

WARNING: 

  To reduce the risk of fire or electric shock, do not expose this 

apparatus to rain or  moisture. This apparatus shall not be 

exposed to dripping or splashing and no objects filled with 

liquids, such as vases shall be placed on the apparatus.

WARNING: 

  This apparatus is a Class I product. This product must be 

connected to a mains socket outlet through an AC to dC 

power supply.

WARNING: 

  The mains plug is used as the disconnect device and shall 

remain readily operable.

WARNING

:   For non-PoE applications, unit is to be connected to a mains 

socket outlet through a Listed Class I power supply rated  

12 VdC or 24 VAC. 

FIGURE A

Dimensions are for the CLFE4US1TPC standalone ComNet module

5.125" (13cm)

4.54" (11.5cm)

4.54" 
(11.5cm)

1.2" (3cm)

1.2" (3cm)

Содержание CLFE4US1TPC

Страница 1: ... It also can be powered by PoE eliminating the need for remote site extra cost power supplies Type tested under NEMA TS2 environmental standards for extended temperature operation from 40C to 75C Certified for use with high bandwidth megapixel or HD IP cameras and tested to network packet performance standards along with major manufacturer compatibility testing Fixed managed L2 functions include 8...

Страница 2: ...ech Support 1 888 678 9427 FIGURE 2 POSSIBLE ETHERNET CONFIGURATION Multiple Configurations are possible Consult ComNet Design Center 3 000ft 914m Cat 5 OR 5 000ft 1524m Coax CLFE16UTP NVR CLFE16UTP PoE Switch CNGE2FE24MSPOE 328ft 100m Cat 5 CLFE4US1TPC IP Cameras IP Cameras 328ft 100m Cat 5 IP Cameras IP Cameras CopperLine Extender Network Switch Coax or UTP Cat 5 PoE CLFE4US1TPC ...

Страница 3: ...ction Connect up to 4 IP cameras to the 10 100BaseT Ethernet port s of the CLFE4US1TPC using standard Cat5 6 cables each 100m length max The link LED on the 10 100 connector should be ON to indicate proper connection between the camera and the CLFE4US1TPC Note WhileeachstandardEthernetportcanoperateateither10or100Mbps theextendedportis100Mbpsmax Therecommendedtotal bandwidthlimitationshouldnotexce...

Страница 4: ... including DVRs that produce heat Protect the power cord from being walked on or pinched particularly at the power source convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servi...

Отзывы: