IN1SMS[POE](C,U)_REV–   10/27/11   PAGE 8

INSTALLATION AND OPERATION MANUAL 

CLFE4+1SMS[POE](C,U) SERIES

TECH SUPPORT: 1.888.678.9427

TABLE 4 – TROUBLESHOOTING GUIDE

Problem

Steps to Take

Indicating LEDs not lighting

Check that power is properly applied to the unit using the correct connector pair.

No Communication

Check Ethernet Link LEDs, Extended Link LEDs, All Connections, Local/Remote switch is set properly. 

Verify that Local units are installed at the head end and that Remote units are installed in the field.

Verify that the Data Rate switches are set to the same data rate on both the Local and Remote units.

Bad Video

Make sure Data Rate and 1/4 Pair Switches are set properly, and the extended distance is within specifications (see Table 

3 – Approximate Maximum Extended Distances).

Units not reaching estimated max 
distances over COAX or UTP

Check extended distance cable and connections. Try connection on a short cable to eliminate possibility of faulty cabling.

Check that the extended distance wire is connected to Extended Distance Port.

Verify that there is no additional equipment (e.g. surge protector) on the Extended Link. The cable should be continuous from 

end to end, with no active components.

Not all cameras visible

Check that the Managed/Unmanaged DIP switch is set to “Managed.”

TABLE 3 – APPROXIMATE MAXIMUM EXTENDED DISTANCES

1

Media

COAX - RG59/U

UTP - 1 pair

UTP - 4 pair

Extended Port Data Rate

10M

100M

10M

100M

10M

100M

Extended Distance

1

5,000 ft 

1,524 m

2,000 ft 

610 m

3,000 ft 

914 m

1,000 ft 

305 m

3,000 ft 

914 m

2,000 ft 

610 m

1

  Distance figures are obtained using in-house testing mirroring installations. Factors such as coaxial/copper cable quality, the number of connectors/

splices in the cable run, the use of PoE, and environmental conditions encountered within the installation may affect the actual transmission 

distance, and should be taken into consideration.

1   Mixed PoE and Non-PoE systems can be implemented.
2   Lower data rates generally provide longer operating distances.

APPLICATION NOTES

Содержание CLFE4+1SMS[POE](C

Страница 1: ...grammed preventing network video flooding with DIP switch selection of the fifth electrical port as uplink or as an unmanaged switch Ports 1 4 of the CLFE4 1SMSPOE can supply up to thirty 30 watts of...

Страница 2: ...CE OR RACK MOUNT COAX UNIT WITH POE EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE...

Страница 3: ...ACK MOUNT UTP UNIT WITH POE FIGURE 4 CLFE4 1SMSPOEU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT WITH POE Operating Power 9 to 12 VDC non PoE 48 to 56VDC PoE Power Consumption 10W non PoE 130W Max PoE...

Страница 4: ...NIT FIGURE 6 CLFE4 1SMSC FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT EXTENDED DISTANCE PORT 4 ETHERNET PORT 3 ETHERNET PORT 2 ETHERNET PORT 1 ETHERNET Operating Power 9 to 15 VDC Power Consumption 10...

Страница 5: ...THERNET FIGURE 7 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT COAX UNIT FIGURE 8 CLFE4 1SMSU FOUR CHANNEL SURFACE OR RACK MOUNT UTP UNIT Operating Power 9 to 15 VDC Power Consumption 10W Black w Whi...

Страница 6: ...systems as illustrated Please contact ComNet s Design Center to discuss your specific requirements Ethernet Connection PoE Power Extended Connection PoE Camera PoE Camera PoE Camera PoE Camera Ethern...

Страница 7: ...ED UNMANAGED DIP SWITCHES Set the Managed Unmanaged switch to the Managed position The default setting for this switch is Managed NOTE In most cases you will want to set the unit to Managed to prevent...

Страница 8: ...on a short cable to eliminate possibility of faulty cabling Check that the extended distance wire is connected to Extended Distance Port Verify that there is no additional equipment e g surge protect...

Страница 9: ...ixing tab of the ferrite core to open it 2 Make three loops around the core with the power cable of the unit 3 Attach the ferrite core to the unit power cord as shown and press it until it clicks Lift...

Страница 10: ...hey must be powered by an external 48 56VDC PSU IMPORTANT SAFEGUARDS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack env...

Отзывы: