COMNET ERICSSON EDACS 300P Скачать руководство пользователя страница 1

EN/LZT 123 5652/1 R1A

Operator’s Manual

EDACS 300P
System/Scan Portable
Radio

Содержание EDACS 300P

Страница 1: ...EN LZT 123 5652 1 R1A Operator s Manual EDACS 300P System Scan Portable Radio...

Страница 2: ...n Critical Radio Systems Inc without any warranty Improvements and changes to this manual necessitated by typographical errors inaccuracies of current information or improvements to programs and or eq...

Страница 3: ...e Only In addition your Com Net Ericsson radio complies with the following Standards and Guidelines with regard to RF energy and electromagnetic energy levels and evaluation of such levels for exposur...

Страница 4: ...nsmit for more than 50 of total radio use time 50 duty cycle Transmitting more than 50 of the time can cause FCC RF exposure compliance requirements to be exceeded The radio is transmitting when the T...

Страница 5: ...his radio operates within the FCC RF exposure limits of this radio Electromagnetic Interference Compatibility During transmissions your Com Net Ericsson radio generates RF energy that can possibly cau...

Страница 6: ...g radio network When using the radio remember these rules 1 It is a violation of FCC rules to interrupt any distress or emergency message As the radio operates in much the same way as a telephone part...

Страница 7: ...nst the Federal law to repeat or otherwise make known anything overheard on the radio Conversations between others sharing your channel must be regarded as confidential OPERATING TIPS The following co...

Страница 8: ...nctions and operation of the EDACS 300P System Scan portable radio For more detailed information about the features and operation refer to the appropriate EDACS 300P Maintenance Manual or contact your...

Страница 9: ...9 Figure 2 EDACS 300P System Model...

Страница 10: ...10 Figure 3 EDACS 300P Scan Model...

Страница 11: ...RATION Locking Unlocking Keypad System Model 1 Press the C M key 2 Press and release the LOCK key Selecting System 1 Press and release the C M key then use the and keys to select the desired system 2...

Страница 12: ...d 2 Press the C M key 3 Press and release the SCN key 4 If the selected Group Channel was not in Scan list it will be added If the selected Group Channel was in Scan list it will be deleted Home Emerg...

Страница 13: ...stem Administrator 2 If programmed an E is displayed in the SYS field and or an alert tone sounds 3 Press the PTT button to transmit your message 4 Release the PTT button when the transmission is comp...

Страница 14: ...d displays SP The GRP field displays the last accessed special call number from the pre programmed list SP 1 SP 2 etc 3 Scan Model Press the or keys to scroll through the pre programmed special call l...

Страница 15: ...d System Model Press the or keys to scroll through the special call list until the desired pre programmed number is displayed SP 1 SP 2 etc or Enter the telephone number to be called Complete the phon...

Страница 16: ...cating the type of call received 4 Group Call If programmed the Group ID of the caller will be displayed in the SYS and GRP fields Individual LID Call If programmed the LID number of the caller or jus...

Страница 17: ...SP The GRP field will display the last accessed special call number from the pre programmed list 4 Enter the LID number or phone number to be stored To recall the last number manually entered from th...

Страница 18: ...ephone number will be displayed in the GRP field 4 Individual LID Call Press and hold the PTT button to initiate the call When signaling is complete the TX and BSY icons are displayed and the Call Ori...

Страница 19: ...on and select the desired System and Channel 2 Ensure that no one is transmitting on the selected Channel by pressing the C M key twice hold down the second press to monitor the channel and or observ...

Страница 20: ...he radio is unsquelched and the message is heard ERROR MESSAGES E3 If at anytime the Synthesizer is unable to load and lock on the channel properly an E3 message will be displayed in the SYS field and...

Страница 21: ...d call received channel assignment System Busy T Three short medium pitched System busy all channels busy or receiving party engaged in call Out of Range System In operative T one low pitched Radio ou...

Страница 22: ...k Make sure the power to the radio is turned OFF 1 Locate the latch on the bottom of the radio 2 Press and hold the latch down toward the back of the radio while sliding the battery towards the bottom...

Страница 23: ...re the power to the radio is turned OFF 1 Align the tabs on the back of the radio with the slots on the battery pack 2 Slide the battery pack towards the top of the radio until it clicks into place Fi...

Страница 24: ...es will negotiate an equitable adjustment in price Labor to perform warranty service will be provided at no charge during the warranty period only for the Equipment covered under Paragraph B 3 To be e...

Страница 25: ...of this page D Replacement batteries shall be warranted only for the remaining unexpired warranty period of the original battery This warranty becomes void if 1 The battery has been subjected to any...

Страница 26: ...26 NOTES...

Страница 27: ...27 NOTES...

Страница 28: ...Com Net Ericsson Critical Radio Systems Inc P O Box 2000 Lynchburg Virginia 24501 1 800 528 7711 Outside USA 1 804 592 7711 Printed in U S A...

Отзывы: