Page 7
Fiberlink® 7500 Series User’s Manual
Fiberlink® 7500 Series
Installation Instructions (cont.)
Installation Instructions | EDID Switch Settings
Figure 1:
Power Connector
DC Input Polarity
9-24 Volts
AC or DC
( - ) Negative
(+) Positive
EDID Switch Settings
Internal
When the switch is in this position, the EDID will be
automatically generated. Alternatively, if EDID
information was previously captured and stored, the
unit will use the stored information.
Loop
The EDID information will be passed through to the DVI
source from the display connected to the loop-through
port of the unit. If no loop-through display is connected,
the DVI source may not generate a DVI signal.
EDID Switch Settings
The EDID Switch has two positions, Internal and Loop, as described in the chart below. For
complete instructions on how to operate the 7500 Series’ Triple EDID function, please refer
to the “Triple EDID Function” section of this manual on page 8.