FASTCOM SERIAL SETTINGS

 

 

These settings can be accessed using the application serialgt.exe (Windows 98/NT) or in the Fastcom Serial Settings tab of 
the Fastcom AsyncPCI Communications Port Properties dialog (Windows 2K/XP), which is found in the device manager under 
Ports (COM & LPT). 

 

CLOCK/4 

Clock divisors of 1 and 4 are available.  Clearing the checkbox selects a divisor of 1 and setting the checkbox 
selects a divisor of 4.  It is best to leave this box unchecked. 
 

RX Trigger 

Determines the number of bytes that will be stored in the receive FIFO on the 16C854 before an interrupt is 
triggered.  Valid values are from 1 to 128 bytes.  The optimal setting is 64 bytes.  For 16C550 compatibility, 
set to 8. 
 

TX Trigger 

Determines the number of bytes remaining in the transmit FIFO on the 16C854 before an interrupt is 
triggered.  Valid values are from 0 to 127 bytes.  The optimal setting is 64 bytes.  For 16C550 compatibility, 
set to 0. 
 

TX Write Size 

Determines the number of bytes sent to the board at a time.  Valid values are from 1 to 128.  This number 
plus the TX Trigger value should not exceed 128.  The optimal value is 64.  For 16C550 compatibility, set to 
16 or 1.  
 

BaudTable (Win2K/XP) 

This table represents the standard baud rates that the Fastcom card will currently support.  If you wish to use 
a non-standard baud, you may enter it into one of the boxes on the table and hit the tab key

 (do not hit enter,

 

hitting enter will exit the program).  This will set the on-board clock generator to a frequency (see Input 
Frequency below) that will divide down to the new baud rate.  The rest of the table will also be updated to 
reflect other bauds that can be used with the calculated clock frequency.  If you wish to return to the standard 
rates, you can set the top box to 115200 and hit tab; the rest of the bauds will be filled in. 
 
Note:  The baud rates that you set will not be available to standard Windows applications like HyperTerminal.  
The new rates will be available to you in your code or in applications that allow user defined baud rates such 
as TTY2, which can be found on the Fastcom disk (Fastcom_CD\Fastcom_disks\AsyncPCI\tty\tty2.exe). 
 

THIS SETTING=THIS BITRATE (Baud Rate Substitution Table) (Win98/NT) 

Under THIS SETTING you will see the standard PC baud rates, from 115.2K to 300.  If you wish to use a 
baud rate not shown, type the baud rate in the box next to 115200 (e.g., type 128K as 128000), and hit the 
tab key.  

Do not hit enter.

  Hitting enter will exit the program.  If the baud rate changes after you tab, move to 

the next box down and try again.  Continue moving down until the baud rate stays the way you want it.  Now 
note the standard PC baud rate to the left of the box you ended on.  You will select this standard baud rate to 
set up your com ports, and the baud rate you require will be substituted.  If you receive an error message 
stating that the maximum baud rate was exceeded, change the Clock Divisor to 1 and try again. 
 

INPUT FREQUENCY 

This is the calculated frequency required to generate the baud rate requested.  When you click OK on the 
Fastcom Serial Settings page, this frequency is sent to the clock generator and the new baud rates will be 
available. 
 

OTHERS 

Auto 485, CTS Disable, 485 Enable, RX Echo Disable, Enable Source, and Sample Rate do not apply to this 
board.  Do not change these options as they will have no positive affect on settings for this board and may 
cause instability. 

Содержание FASTCOM: 232/4-PCI

Страница 1: ...F A ASTCOM DAPTERS FASTCOM 232 4 PCI Advanced Four Channel RS 232 Interface for PCI Bus Hardware Reference Manual Manufactured by 9011 E 37th St N Wichita KS 67226 2006 ...

Страница 2: ......

Страница 3: ...including those to reproduce this document or parts thereof in any form without permission in writing from Commtech Inc FASTCOM and SMART14 are trademarks of Commtech Inc IBM is a registered trademark of International Business Machines Corporation Microsoft is a registered trademark of Microsoft Corporation WINDOWS is a trademark of Microsoft Corporation ...

Страница 4: ...loop back plug description 2 2 12 Changed warranty to 2 years 2 3 6 Added link to installation manual 2 4 10 Updated contact information 2 5 3 4 6 8 Changed 1 5 Mbaud to 725 Kbaud Updated Testing Installation and Fastcom Serial Settings 2 6 10 Changed warranty period to lifetime ...

Страница 5: ...cription Block Diagram 3 Specifications Features 4 Board Layout 5 INSTALLATION Installing the Hardware Software 6 Testing the Installation 6 FASTCOM SERIAL SETTINGS 8 ADAPTER CABLE 9 TECHNICAL SUPPORT 10 APPENDIX A 16C854 UART Technical Data 11 ...

Страница 6: ......

Страница 7: ...ass B Limits EN 50082 1 1992 EMC Generic Immunity Standard Part 1 Residential Commercial and Light Industry IEC 801 2 1984 Method of Evaluating Susceptibility to Electrostatic Discharge Level 4 IEC 801 3 1984 Radiated Electromagnetic field Requirements Level 3 IEC 801 4 1988 Electrical Fast Transient Burst Requirements Level 2 Products listed on this declaration are exempt from the requirements of...

Страница 8: ...2 ...

Страница 9: ...n utilize all standard baud rates plus a high speed mode capable of up to an amazing 725 Kbps RS 232 data rates are realistically limited by cable length and driver receiver characteristics to data rates less than 725 Kbaud If your application requires faster data rates or better noise immunity we suggest you try our Mega Baud family of RS232 adapters or our RS 422 family of PCI adapters such as t...

Страница 10: ...d FEATURES High performance 16C854 UARTS Standard on the Fastcom 232 4 PCI no extra charge All baud rates up to 725 Kbaud 128 byte FIFOs for improved throughput User programmable baud rate Switchless design Durable Cables with RFI shielding Comprehensive Hardware and Software Documentation Made in Wichita Kansas USA RS 232 data rates are realistically limited by cable length and driver receiver ch...

Страница 11: ...CI BOARD LAYOUT TRANSMIT RECEIVE LEDs DB37 CONNECTOR PCI CONTROLLER 16C854 UART PACKING LIST FASTCOM 232 4 PCI CARD CABLE ASSEMBLY FASTCOM CD If an omission has been made please call technical support for a replacement ...

Страница 12: ... the Fastcom Async PCI series cards section to return to this manual TESTING THE INSTALLATION 2 3 4 5 6 8 20 To fully test the installation of your Fastcom 232 4 PCI you will need to build a loop back plug Materials needed are a DB25 female receptacle solder cup style and a few short pieces of 20 or 24 AWG stranded wire This loop back plug can be used to test any RS 232 port Jumper the pins togeth...

Страница 13: ...ffending device 3 IRQ steering is enabled on Windows 98 and Windows is not assigning an IRQ to the Fastcom card Try disabling IRQ steering or varying the options in Control Panel System Device Manager System Devices PCI Bus 4 Multiple COMx assignments In Windows NT the driver setup assumes that there are not any ports installed above COM4 and starts assigning the Fastcom ports at COM5 If there is ...

Страница 14: ...be updated to reflect other bauds that can be used with the calculated clock frequency If you wish to return to the standard rates you can set the top box to 115200 and hit tab the rest of the bauds will be filled in Note The baud rates that you set will not be available to standard Windows applications like HyperTerminal The new rates will be available to you in your code or in applications that ...

Страница 15: ...andard DB25 male plugs DB37 PIN DESCRIPTION DB25 PIN DESCRIPTION Four Plugs DCD GND DSR CTS RTS RXD TXD RI DTR 13 2 7 2 1 1 11 10 9 8 6 5 4 3 25 24 23 22 21 20 19 18 17 16 15 14 N C DCD3 GND CTS3 RXD3 RI4 DTR4 DSR4 RTS4 TXD4 DCD2 GND CTS2 RXD2 RI1 DTR1 DSR1 RTS1 TXD1 RI3 DTR3 DSR3 RTS3 TXD3 DCD4 GND CTS4 RXD4 RI2 DTR2 DSR2 RTS2 TXD2 DCD1 GND CTS1 RXD1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1...

Страница 16: ...tch positions your cables and your program We recommend that you build the loop back plug that is described in the Programming section of this manual With that plug you can quickly isolate the problem to the board cables or software If you still have unresolved questions use the following procedure to get technical support 1 Call our Technical Support Staff at 316 636 1131 They are on duty from 9 ...

Страница 17: ...11 APPENDIX A 16C854 UART DATA ...