![CommScope ValuLine VHLP Series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/commscope/valuline-vhlp-series/valuline-vhlp-series_installation-instructions-manual_2643616024.webp)
Ensure brackets and nuts are
bolted rigidly together as shown
with no visible threads.
(Viewed from underside for clarity)
Leave loose until
adjustment is
completed
Structural Member
(Circular)
Torque to
95Nm 5%
K2
Torque to
60Nm 5%
Torque to
60Nm 5%
ATTACHMENT TO CIRCULAR STRUCTURAL MEMBERS.
Page 24 of 30
7722483
SECTION 8
INSTALLATION
INSTRUCTIONS
Clamps must be attached to a circular structural member (Dia 48mm - 120mm)
capable of supporting 7694N in accordance with TIA-222.
The maximum allowable relative deflection between the antenna mounting pipe
and the strut attachment point must be less than 2mm at survival wind
speed of the antenna.
MOUNT ATTACHMENT AND ALIGNMENT
Содержание ValuLine VHLP Series
Страница 1: ...7722483 Rev F ...
Страница 4: ...Page 4 of 30 7722483 SAFETY INSTRUCTIONS SECTION 2 INSTALLATION INSTRUCTIONS ...
Страница 5: ...Page 5 of 30 7722483 SAFETY INSTRUCTIONS SECTION 2 INSTALLATION INSTRUCTIONS ...
Страница 9: ...A B C D D2 D1 Page 9 of 30 7722483 EQUIPMENT AND TOOLS SECTION 3 INSTALLATION INSTRUCTIONS ...
Страница 30: ...Page 30 of 30 7722483 GENERAL INFORMATION SECTION 9 INSTALLATION INSTRUCTIONS ...