5.1.1 

Insert the leading connector pulling eye (installed in the factory) into the pulling swivel mesh.

 

Note:

 Do not pull on the connector directly. Use either the pulling swivel mesh as shown or wrap the lead end of the cable 

around your hand as described in step 5.3.2. Do not exceed 40 lbs. of force. 

5.1.2 

Wrap several layers of vinyl tape around the pulling swivel and trailing connector.

5�2 

Preparing HMFOC cable

The HMFOC connector at the end of the terminal’s tail is the non-pinned female type. The connector is protected by a dust 

cap. A pulling eye is integrated into the end of the dust cap for pulling the drop cable.

Note:

 Do not exceed a pulling force of 445N (100 lbs) and when connected, don’t exceed cable pull of 111 N (25 lbs). A 

properly rated breakaway swivel should be used between the pull rope and the pulling cap.

5�3 

Pulling the cable

5.3.1 

Tie a pulling cord to the swivel (MPO) or dust cap (HMFOC) and guide the pulling cord into the conduit or duct. 

Trailing connector

(Leave outside mesh)

Leading connector

(Place inside mesh)

Cable pulling 

swivel

Wrap the pulling swivel and 

trailing connector with vinyl tape

Guide pulling

swivel into conduit

OPTIONAL

CONDUIT OR DUCT

TERMINATION

LOCATION

BUDI-R

MOUNTING

LOCATION

EXTERNAL

SPOOL

BUDI-R

Содержание TC-1511-IP

Страница 1: ...d minimum bend radius Always observe the recommended bend radius limit when installing fiber optic cables and patch cords 2 2 Infrared radiation is invisible and can seriously damage the retina of the eye Do not look into the ends of any optical fiber Do not look directly into the optical adapters of the adapter packs Do not assume the laser power is turned off or that the fiber is disconnected at...

Страница 2: ...ed to the spool with cardboard connections and cable ties 4 2 Place it on the stand as shown 4 3 Spool is ready to pay out 5 Paying out the cable on external spool if applicable Caution The cable is not designed for outdoor direct burial or outdoor aerial applications Do not pull fiber perpendicular from the BUDI R Pull fiber parallel with the wall and route to the equipment 5 1 Preparing the MPO ...

Страница 3: ... The connector is protected by a dust cap A pulling eye is integrated into the end of the dust cap for pulling the drop cable Note Do not exceed a pulling force of 445N 100 lbs and when connected don t exceed cable pull of 111 N 25 lbs A properly rated breakaway swivel should be used between the pull rope and the pulling cap 5 3 Pulling the cable 5 3 1 Tie a pulling cord to the swivel MPO or dust ...

Страница 4: ...ng eye s and use the hand wrap method shown to pull the cable to the point where the cable will be terminated 6 Remove packaging 6 1 If applicable remove the BUDI R from the external spool by cutting the cable ties Note Unwind the loop of cable within the lead loop holder 6 2 Remove the cardboard cover Wrap cable once around palm of hand Grasp cable and pull ...

Страница 5: ...ears at the outside the box Note Due to different local mounting practices no mounting hardware is provided with the box Note If necessary reinforce the mounting surface with a 3 4 plywood panel 7 2 Rotate the screw counterclockwise to unlock 7 3 Rotate the cover open 7 4 The cover can be locked at 90 7 5 The cover can be removed completely 96 mm 3 8 IN 195 mm 7 7 IN 76 2 mm 3 IN 137 2 mm 5 4 IN 1...

Страница 6: ...licable 8 2 Loosen the fiber spool by sliding the lock backwards and pull the MPO HMFOC connector out 8 3 Unspool the MPO HMFOC Cables and pay out any additional length of cable required at the termination point 8 4 Rotate the fiber spool so the SC connectors are positioned facing down again Position the spool and lock it in place 8 5 Slide the cable between the foam seals at the bottom ...

Страница 7: ...e labeled Make sure to select the correct connector to connect to the designated adapter port see section 9 1 9 Installing patch cords 9 1 Identify the correct SC adapter Bottom row of the adapter pack SC 1 12 correspond with cable subunit 1 see brady label on connector at the cable end Top row of the adapter pack SC 13 24 correspond with cable subunit 2 Important It is important to install first ...

Страница 8: ...nstructions ADCP 90 159 or by locally approved procedures 9 3 Position the connector in the correct orientation connector key facing to the right as shown in figure above 9 4 Connect the SC connectorized cable to its assigned port A clicking sound is observed when the connector is properly seated 9 5 Route the patch cords through the drop cable foam seal The first 3 cords are routed to the first s...

Страница 9: ...y with a number of CommScope s facilities across the globe certified in accordance with international standards including ISO 9001 TL 9000 and ISO 14001 Further information regarding CommScope s commitment can be found at www commscope com About Us Corporate Responsibility and Sustainability This product may be covered by one or more U S patents or their foreign equivalents For patents see www cs ...

Отзывы: