CommScope Ruckus ICX 7750 Скачать руководство пользователя страница 66

64

Ruckus ICX 7750 Switch Hardware Installation Guide 

Part Number: 53-1003900-10

Managing the Ruckus ICX 7750

Replacing a power supply unit

 

Table 21

 on page 57 describes the Ruckus ICX 7750 power supply status LED colors, behaviors, and actions required, if any.

Determining the need to replace a power supply

Use one of the following methods to determine the status of the power supplies:

Check the PSU1 and PSU2 LEDs on the switch front panel or power supply status LED (refer to 

“LED patterns”

 on page 55).

Enter the 

show chassis

 command at the prompt to display power supply status.

Time and items required

Replacing a power supply in the Ruckus ICX 7750 should take less than two minutes to complete.

You need the following items to replace a power supply in a Ruckus ICX 7750:

A new power supply (must have the same part number and the same airflow label as the power supply being replaced)

A #1 Phillips screwdriver

Replacing a power supply

Complete the following steps to replace a power supply in a Ruckus ICX 7750.

1.

To leave the Ruckus ICX 7750 in service while replacing a power supply, verify that the other power supply (the one not being 
replaced) has been powered on for at least four seconds and has a steady green status LED.

2.

Before opening the package that contains the power supply, touch the bag to the switch casing to discharge any potential static 
electricity. Ruckus recommends using an ESD wrist strap during installation.

3.

Remove the power supply from the anti-static shielded bag.

4.

Ensure that the replacement power supply has the same part number and airflow label as the power supply being replaced.

5.

Unplug the power cord from the power supply that is being replaced.

6.

Using the Phillips screwdriver, unscrew the two captive screws on the power supply.

7.

Remove the power supply from the chassis by pulling the handle on the power supply out and away from the chassis.

NOTE

Do not force the installation. If the power supply does not slide in easily, ensure that the power supply is correctly oriented before 
continuing.

8.

Holding the power supply level, guide it into the carrier rails on each side and gently push it all the way into the slot, ensuring that 
it firmly engages with the connector.

CAUTION

Because the cooling system relies on pressurized air, do not leave any of the power supply and fan tray slots empty longer 
than two minutes while the switch is operating. If a power supply or fan tray fails, leave it in the switch until it can be replaced.

CAUTION

Disassembling any part of the power supply and fan tray voids the warranty and regulatory certifications. There are no 
user-serviceable parts inside the power supply and fan tray. 

Содержание Ruckus ICX 7750

Страница 1: ...Part Number 53 1003900 10 Publication Date 30 September 2020 RUCKUS ICX 7750 Switch Hardware Installation Guide HARDWARE INSTALLATION GUIDE ...

Страница 2: ...OM COMPUTER VIRUS AND WARRANTIES ARISING FROM COURSE OF DEALING OR COURSE OF PERFORMANCE CommScope does not represent or warrant that the functions described or contained in the Materials will be uninterrupted or error free that defects will be corrected or are free of viruses or other harmful components CommScope does not make any warranties or representations regarding the use of the Materials i...

Страница 3: ...s 11 Views of the Ruckus ICX 7750 switch 12 Ruckus ICX 7750 slot and Ethernet port numbering 14 Supported expansion module 15 Supported transceivers and cables 16 High power 40 GbE optic support 16 Breakout cables 17 QSFP to SFP adapter support 17 10G SFPP TX A transceiver support 17 Installing the Ruckus ICX 7750 Shipping carton contents 19 Installation and safety considerations 20 Electrical con...

Страница 4: ... copper port 44 Connecting a network device to a fiber port 44 Connecting breakout cables to 40 GbE ports 45 Stacking Ruckus ICX 7750 switches 45 Stacking ports 45 Stacking configuration requirements 46 Stacking cables 47 Extended distance stacking 47 Stack size 47 Stacking topologies 47 Ruckus ICX 7750 Operation LED activity interpretation 51 Ruckus ICX 7750 front panel LEDs 51 Ruckus ICX 7750 re...

Страница 5: ...physical dimensions 74 Environmental requirements 74 Power supply specifications per PSU 75 Power consumption typical configuration 75 Power consumption maximum configuration 76 Power consumption modules 76 Data port specifications Ethernet 76 Serial port specifications pinout mini USB 76 Serial port specifications pinout RJ 45 77 Serial port specifications protocol 77 Memory specifications 77 Reg...

Страница 6: ...4 Ruckus ICX 7750 Switch Hardware Installation Guide Part Number 53 1003900 10 ...

Страница 7: ...old and italic text identify command syntax components Delimiters and operators define groupings of parameters and their logical relationships TABLE 1 Text conventions Convention Description Example monospace Identifies command syntax examples device config interface ethernet 1 1 6 bold User interface UI components such as screen or page names keyboard keys software buttons and field names On the ...

Страница 8: ... Other technical documentation content is available without logging into the Ruckus Support Portal White papers data sheets and other product documentation are available at https www ruckuswireless com Convention Description Boldface text Identifies command names keywords and command options Italics text Identifies a variable value In Fibre Channel products a fixed value provided as input to a com...

Страница 9: ...to the Open a Case section Priority 2 P2 High Network or service is impacted but not down Business impact may be high Workaround may be available Go to the Open a Case section Priority 3 P3 Medium Network or service is moderately impacted but most business remains functional Go to the Self Service Resources section Priority 4 P4 Low Request for information product documentation or product enhancem...

Страница 10: ...vices and Support Using these resources will help you to resolve some issues and will provide TAC with additional data from your troubleshooting analysis if you still require assistance through a support case or RMA If you still require help open and manage your case at https support ruckuswireless com case_management ...

Страница 11: ... includes descriptions of new information added to this edition TABLE 2 Summary of enhancements added to this edition Feature Description Described in 10G SFPP TX transceiver support Added guidelines for using the 10G SFPP TX transceiver 10G SFPP TX A transceiver support Power and cooling Added information on fan speeds and temperature thresholds Monitoring power and cooling ...

Страница 12: ...10 Ruckus ICX 7750 Switch Hardware Installation Guide Part Number 53 1003900 10 About this Document What s new in this document ...

Страница 13: ...serial management port mini USB to configure and manage the switch through the CLI One USB port for the transfer of software and configuration files from an external disk drive Ruckus ICX 7750 orderable models The Ruckus ICX 7750 consists of three orderable models as shown in Table 3 Ruckus ICX 7750 customizable models The Ruckus ICX 7750 base systems do not ship with power supplies or fans Fans a...

Страница 14: ...E 504 W AC power supply power supply side exhaust port side intake airflow RPS9 I 504 W AC power supply power supply side intake port side exhaust airflow RPS9DC E 504 W DC power supply power supply side exhaust port side intake airflow RPS9DC I 504 W DC power supply power supply side intake port side exhaust airflow ICX 7750 FAN E Ruckus ICX 7750 kit of four fans exhaust airflow ICX 7750 FAN I Ru...

Страница 15: ...X 7750 48C switch FIGURE 3 Front view of the Ruckus ICX 7750 48C Figure 4 shows the rear view of the Ruckus ICX 7750 switch 1 SFP ports 1 1 1 48 5 Console port 2 QSFP ports XL2 1 XL2 6 6 Reset button 3 System LEDs 7 SFP port LEDs 4 Stack unit ID display 8 QSFP port LEDs 1 10GBase T RJ 45 ports 1 1 1 48 5 Console port 2 QSFP ports XL2 1 XL2 6 6 Reset button 3 System LEDs 7 10GBase T port LEDs 4 Sta...

Страница 16: ...the front of the Ruckus ICX 7750 26Q device Slot 1 contains 10 40 GbE QSFP ports XL1 1 through XL1 20 odd port numbers on the top row with port XL1 1 on the left and port XL1 20 on the right Slot 2 contains 10 40 GbE QSFP ports XL2 1 through XL2 6 ports XL2 1 XL2 3 and XL2 5 are on the top row left to right and ports XL2 2 XL2 4 and XL2 6 are on the bottom row left to right FIGURE 5 Ruckus ICX 775...

Страница 17: ...on the left Slot 2 contains 10 40 GbE QSFP ports XL2 1 XL2 3 and XL2 5 on the top row left to right and ports XL2 2 XL2 4 and XL2 6 on the bottom row left to right FIGURE 7 Ruckus ICX 7750 48C slot numbering Slot 3 is located on the rear of the Ruckus ICX 7750 switches and contains ports XL3 1 XL3 3 and XL3 5 on the top row left to right and ports XL3 2 XL3 4 and XL3 6 on the bottom row left to ri...

Страница 18: ...r these optics based on airflow direction and switch model The Ruckus ICX 7750 also supports 40GBASE SR BD bi directional BiDi QSFP transceivers with duplex LC optics The 40 GbE BiDi optics support two 20 GbE channels over duplex fiber cable with the transmit and receive of each channel operating at two wavelengths on a single fiber 1 Assembly screws 3 Expansion module power LED 2 Release lever la...

Страница 19: ...g rather than breakout cables An SFP transceiver SR LR or USR inserted in the QSFP to SFP adapter behaves as if it is connected to the first of the 4 breakout ports on the 40 GbE QSFP interface with no other ports available in the breakout The 4x10 GbE breakout mode must be configured on the QSFP interface 10G SFPP TX A transceiver support The 10G SFPP TX A transceiver consumes significantly more ...

Страница 20: ...cables For example If you are using four 10G SFPP TX A you must leave four SFP ports empty TABLE 7 Ruckus ICX 7750 10G SFPP TX A transceiver support Model 10G SFPP TX A installed location For each 10G SFPP TX A inserted this many SFP ports must remain unused ICX 7750 48F Port Group 1 1 1 1 to 1 1 32 1 Port Group 2 1 1 33 to 1 1 48 1 ...

Страница 21: ... Ruckus ICX 7750 devices ship with all of the following items included in the shipping carton When unpacking the device verify that the contents of the shipping carton is complete if any items are missing contact the place of purchase The Ruckus ICX 7750 device An accessory kit containing the following items Rack mounting kit containing two L shaped mounting brackets and two sets of eight sink hea...

Страница 22: ...in the rack should force air in the same direction to avoid intake of exhaust air Some combinations of intake and exhaust airflows may not be compatible with your environment Consult your fan and power supply module FRU kit to determine the correct configuration The ambient air temperature does not exceed 50 C 122 F while the Ruckus ICX 7750 26Q or Ruckus ICX 7750 48F switch is operating or 40 C 1...

Страница 23: ...bers Velcro like wraps are recommended Plan for the rack space required for cable management before installing the switch Leave at least 1 m 3 28 ft of slack for each port cable This provides room to remove and replace the switch allows for inadvertent movement of the rack and helps prevent the cables from being bent to less than the minimum bend radius For easier maintenance label the cables and ...

Страница 24: ... performed using the CLI with a direct serial connection Ruckus FastIron Management Configuration Guide 8 Connect network equipment to the system Connecting network devices on page 43 9 Test IP connectivity to other devices by pinging them and tracing routes Ruckus FastIron Management Configuration Guide 10 Continue configuring the device using the CLI Ruckus FastIron Management Configuration Guid...

Страница 25: ...es near the input power connectors DANGER Disconnect the power cord from all power sources to completely remove power from the device CAUTION Before plugging a cable to any port be sure to discharge any static charge stored on the cable by touching the electrical contacts to ground surface CAUTION If the installation requires a different power cord than the one supplied with the device make sure y...

Страница 26: ...ircuit to the rack assembly is not overloaded Grounding Rack mounted equipment should be properly grounded Particular attention should be given to supply connections other than direct connections to the mains electricity supply To mount the product into a four post rack you can order a four post rack kit with the part number XBR R000295 For the procedure to install this kit refer to Installing the...

Страница 27: ...k 1 Remove the rack mount kit from the shipping carton The kit contains the following items Two L shaped mounting brackets Eight 8 32 x 5 16 in panhead Phillips screws 2 Attach the mounting brackets to the sides of the device as illustrated in Figure 12 using the 8 32 x 5 16 in screws FIGURE 12 Attaching the mounting brackets for a Ruckus ICX 7750 3 Position the device in the rack providing tempor...

Страница 28: ...evice and less interference in the aisle at the front of the rack NOTE Hardware devices illustrated in these procedures are only for reference and may not depict the device you are installing into the rack Installation requirements Review the installation and facility requirements for your product before mounting the device Refer to the hardware installation guide for your product for more informa...

Страница 29: ...n XBR R000295 FIGURE 14 Rack kit parts Flush front mounting the device in the rack CAUTION Use the screws specified in the procedure Using longer screws can damage the device 1 Front brackets 2 6 Screw 8 32 x 5 16 in panhead Phillips 8 2 Bracket extensions 2 7 Screw 8 32 x 5 16 in flathead Phillips 16 3 Rear brackets short 2 8 Screw 6 32 x 1 4 in panhead Phillips 8 4 Rear brackets medium 2 9 Screw...

Страница 30: ...lling the device in the rack on page 29 4 Attaching the rear brackets to the extensions on page 30 5 Attaching the rear brackets to the rack posts on page 31 Attaching the front brackets Complete the following steps to attach the front brackets to the device 1 Position the right front bracket with the flat side against the right side of the device at the front of the device as shown in Figure 15 2...

Страница 31: ...tension bracket and then into the holes on the side of the device Use the upper and lower screw holes leaving the center holes empty 4 Repeat Step 1 and Step 2 to attach the left extension bracket to the left side of the device 5 Tighten all the 8 32 x 5 16 in screws to a torque of 15 in lb 17 cm kg FIGURE 16 Attaching the extension brackets to the device Installing the device in the rack Complete...

Страница 32: ...to the extensions There are short and long rear brackets that you can use for this step Choose the correct bracket for the depth of your rack 1 Select the proper length rear bracket for your rack depth 2 Slide the right rear bracket onto the right extension as shown in Figure 18 The short rear brackets are shown Use the first and third vertical pairs of holes for the screws Refer to Figure 19 for ...

Страница 33: ...ttach the rear brackets to the rack posts 1 Attach the right rear bracket to the right rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts as shown in Figure 20 Use the upper and lower holes in the bracket 2 Attach the left rear bracket to the left rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 3 Ti...

Страница 34: ...tions are the same for a 1 5U or 2U device The illustrations in the rack installation procedures are for reference only and may not show the actual device Complete the following tasks to install the device in a four post rack 1 Attaching the front brackets to the rear of the device on page 33 2 Attaching the extensions to the front of the device on page 33 3 Installing the device in the rack on pa...

Страница 35: ...bracket and then into the holes on the side of the device Use the upper and lower screw holes leaving the center holes empty 3 Repeat Step 1 and Step 2 to attach the left rear bracket to the left side of the device 4 Tighten all the 8 32 x 5 16 in screws to a torque of 15 in lb 17 cm kg FIGURE 21 Attaching the front brackets to the rear of the device Attaching the extensions to the front of the de...

Страница 36: ...llowing steps to install the device in the rack 1 Position the device in the rack as shown in Figure 23 providing temporary support under the device until the rail kit is secured to the rack 2 Attach the right front bracket to the right rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 3 Attach the left front bracket to the le...

Страница 37: ...rect bracket for the depth of your rack 1 Select the proper length rear bracket for your rack depth 2 Slide the right rear bracket onto the right extension as shown in Figure 24 The short rear brackets are shown Use the first and third vertical pairs of holes for the screws Refer to Figure 25 for the positioning of the medium or long brackets and screws 3 Attach the brackets using four 6 32 x 1 4 ...

Страница 38: ...the front rack posts Complete the following steps to attach the rear brackets to the front rack posts 1 Attach the right rear bracket to the right front rack post using two 10 32 x 5 8 in screws and two retainer nuts as shown in Figure 26 Use the upper and lower holes in the bracket 2 Attach the left rear bracket to the left front rack post using two 10 32 x 5 8 in screws and two retainer nuts Use...

Страница 39: ...m The rear panel of the Ruckus ICX 7750 includes a single screw grounding terminal The surface area around this terminal is not painted to provide a good electrical connection Before connecting power to the device the grounding terminal must be connected to ground to ensure proper operation and to meet electromagnetic interference EMI and safety requirements FIGURE 27 Connecting the grounding term...

Страница 40: ...em 1 Install alternating current AC and direct current DC power supplies in the switch 2 Attach AC or DC power cables to the power supply connectors on the rear panel 3 Connect the power cables to the 100 240 VAC or 48 VDC power source NOTE To turn the system off simply unplug the power cable or cables NOTE A power source should be installed near the equipment and should be easily accessible Power...

Страница 41: ...filler panel a Using a Phillips screwdriver unscrew the screws on the filler panel b Remove the filler panel 3 Before opening the package that contains the power supply touch the bag to the switch casing to discharge any potential static electricity Ruckus recommends using an ESD wrist strap during installation 4 Remove the power supply from the anti static shielded bag 5 Holding the power supply ...

Страница 42: ...ssis attachment screws located in the upper right and lower left of the power supply unit using a Phillips screwdriver Refer to item 1 in Figure 29 FIGURE 29 DC power supply screws 2 Before opening the package that contains the DC power supply touch the bag of the switch casing to discharge any potential static electricity Ruckus recommends using an ESD wrist strap during installation 3 Remove the...

Страница 43: ...LED on the front of the device should turn green to confirm that the power supply is correctly installed and supplying power Refer to Ruckus ICX 7750 front panel LEDs on page 51 Attaching a PC or terminal To assign an IP address you must have access to the command line interface CLI The CLI is a text based interface that can be accessed through a direct serial connection to the device and through ...

Страница 44: ...CX 7750 is described in detail in the Ruckus FastIron Management Configuration Guide Installing an SFP or a QSFP transceiver To monitor the transceivers the show media command output shows the transceiver information for all interfaces on the switch Ruckus provides support for third party transceivers but may require a Ruckus transceiver be used for troubleshooting Support will not be provided if ...

Страница 45: ...e unlocked position place the transceiver in the correctly oriented position on the port as shown in Figure 31 5 Slide the transceiver into the port until you feel it click into place then close the bail Transceivers are keyed to prevent incorrect insertion NOTE Each SFP transceiver has a 10 pad gold plated edge connector on the bottom The correct position to insert an SFP transceiver in the upper...

Страница 46: ...ling an SFP or a QSFP transceiver on page 42 Cable the fiber optic transceiver Cabling a fiber optic transceiver Use the following steps to cable a fiber optic transceiver 1 Remove the protective covering from the fiber optic port connectors and store the covering for future use 2 Before cabling a fiber optic transceiver Ruckus strongly recommends cleaning the cable connectors and the port connect...

Страница 47: ...ailability stacking with hitless failover on six full duplex 40 Gbps stacking ports Ruckus ICX 7750 Switches can be stacked using standard full 40 Gbps QSFP ports per switch providing a maximum stacking bandwidth of 480 Gbps Stacking ports There are six QSFP ports on the front panel slot 2 and six QSFP ports on the rear panel slot 3 that can be used as stacking ports Use either the front panel sta...

Страница 48: ...onsisting of multiple ports which increases stacking bandwidth and provides resiliency Up to two stack trunks are supported and each trunk can include up to three ports Only ports that are in sequential order can be configured as a stacking trunk A default port that is either port 1 2 1 or 1 2 4 in slot 2 or port 1 3 1 or 1 3 4 in slot 3 is always the first sequential port in a trunk Possible 3 po...

Страница 49: ... 1 3 1 or 1 3 4 Due to the limitation on the Ruckus ICX7750 48C and the ICX7750 48F where 40GBASE LR4 optics are supported only in ports 1 2 5 1 2 6 1 3 5 or 1 3 6 extended distance stacking is not supported for 40GBASE LR4 optics Table 9 shows the approved optics and stacking distance combinations Stack size The Ruckus ICX 7750 supports up to 12 units in a stack You can mix any number of Ruckus I...

Страница 50: ...ng or closed loop The closed loop connection provides a redundant path for the stack link so if one link fails stack communications can be maintained For example in a three unit stack using a ring topology unit 1 connects to unit 2 unit 2 connects to unit 3 and unit 3 connects to unit 1 Figure 35 shows a supported rear panel ring stacking topology FIGURE 35 Rear panel ring stacking topology Figure...

Страница 51: ...10 Installing the Ruckus ICX 7750 Stacking Ruckus ICX 7750 switches Figure 37 shows a supported rear panel ring trunk stack topology FIGURE 37 Rear panel ring trunk stack topology NOTE For more information about stacking refer to the Ruckus FastIron Stacking Configuration Guide ...

Страница 52: ...50 Ruckus ICX 7750 Switch Hardware Installation Guide Part Number 53 1003900 10 Installing the Ruckus ICX 7750 Stacking Ruckus ICX 7750 switches ...

Страница 53: ...ash either of the colors during boot POST or other diagnostic tests This is normal it does not indicate a problem unless the LEDs do not indicate a healthy state after all boot processes and diagnostic tests are complete Ruckus ICX 7750 front panel LEDs The Ruckus ICX 7750 26Q has the following LEDs on the front panel Two power supply unit PSU bicolor status LEDs green and amber labeled PSU1 and P...

Страница 54: ...bE mode and 4x10 GbE breakout mode Figure 39 shows the LEDs on the Ruckus ICX 7750 48C front panel The up arrow port status LEDs for the 1 10 GbE ports correspond to the upper odd numbered ports the down arrow port status LEDs correspond to the lower even numbered ports 1 PSU1 and PSU2 status LEDs PSU1 corresponds to the right power supply slot on the rear panel and PSU2 corresponds to the left po...

Страница 55: ...tus LEDs green for 10 GbE and amber for 1 GbE that indicate the 1 GbE or 10 GbE mode of operation Four bicolor status LEDs green and amber for each of the six QSFP ports that indicate the status of the ports in 40 GbE mode and 4x10 GbE breakout mode Figure 40 shows the LEDs on the Ruckus ICX 7750 48F front panel The up arrow port status LEDs for the 10 GbE ports correspond to the upper odd numbere...

Страница 56: ... and amber Four bicolor status LEDs green and amber for each of the six QSFP ports that indicate the status of the ports in 40 GbE mode and 4x10 GbE breakout mode Power supply LEDs One status LED on each installed power supply Fan tray LEDs One status LED on each installed fan tray Figure 41 shows the LEDs on the rear panel of the Ruckus ICX 7750 1 Upper 1 10 GbE port LEDs 4 MS and DIAG status LED...

Страница 57: ... 10 GbE mode lanes 2 3 and 4 link activity LEDs 8 Expansion module power LED TABLE 10 PSU1 and PSU2 LEDs LED state Status of hardware Recommended action Off no light System is off or there is no power Verify the system is on and has completed booting Steady green PSU is on and functioning properly No action required Steady amber PSU is missing power or in a faulty state Verify that the PSU power c...

Страница 58: ...o action required TABLE 15 Management port right activity status LED LED state Status of hardware Recommended action Off no light Not cabled or no packets are being transmitted or received No action required Blinking green There is traffic and packets are being transmitted or received No action required TABLE 16 1 10 GbE RJ 45 port LEDs LED state Status of hardware Recommended action Off no light ...

Страница 59: ...There is 1 GbE traffic and packets are being transmitted or received No action required Steady amber Link is up in 10 100 Mbps mode No action required Blinking amber There is 10 100 Mbps traffic and packets are being transmitted or received No action required TABLE 21 Power supply unit LED LED state Status of hardware Recommended action Off no light PSU is not powered on Verify that the PSU power ...

Страница 60: ... internal power supply may be defective In this case contact Ruckus Technical Support for assistance The device contains temperature sensors that the software reads based on a configurable device poll time The device has two automatic speed fan control settings based on the temperature To protect the device from overheating the following temperature threshold levels exist The warning level is the ...

Страница 61: ... temperature thresholds Speed 1 NM 61 deg C Speed 2 53 81 deg C shutdown Fan 1 Air Flow Direction Front to Back Fan 2 Air Flow Direction Front to Back Fan 3 Air Flow Direction Front to Back Fan 4 Air Flow Direction Front to Back CPU Temperature Readings Current temperature 29 0 deg C Left Fan Temperature Readings Current temperature 36 5 deg C Right Fan Temperature Readings Current temperature 34 ...

Страница 62: ...60 Ruckus ICX 7750 Switch Hardware Installation Guide Part Number 53 1003900 10 Ruckus ICX 7750 Operation Monitoring power and cooling ...

Страница 63: ...uckus ICX 7750 is powered on and running This section provides information about the following tasks Removing a copper or fiber optic module Cabling a fiber optic module Cleaning the fiber optic connectors Removing a copper or fiber optic module While removing a copper or fiber optic module be sure to wear an ESD wrist strap that is connected to ground Before removing a fiber optic transceiver hav...

Страница 64: ...ver 1 Remove the protective covering from the fiber optic port connectors and store the covering for future use NOTE Before cabling a fiber optic transceiver Ruckus strongly recommends cleaning the cable connectors and the port connectors For more information refer to Cleaning the fiber optic connectors on page 62 2 Gently insert the cable connector a tab on each connector should face upward into ...

Страница 65: ...t have the same label affixed so that airflow direction is consistent Figure 42 illustrates examples of the airflow labels FIGURE 42 Examples of airflow symbols The green E symbol indicates an exhaust FRU This unit pulls air in from the front of the switch and exhausts it out the rear side This is called front to back airflow or forward airflow The orange I symbol indicates an intake FRU This unit...

Страница 66: ... 2 Before opening the package that contains the power supply touch the bag to the switch casing to discharge any potential static electricity Ruckus recommends using an ESD wrist strap during installation 3 Remove the power supply from the anti static shielded bag 4 Ensure that the replacement power supply has the same part number and airflow label as the power supply being replaced 5 Unplug the p...

Страница 67: ... Disassembling any part of the power supply and fan tray voids the warranty and regulatory certifications There are no user serviceable parts inside the power supply and fan tray Determining the need to replace a fan tray Enter the show chassis command in the command line interface to display fan status Time and items required Replacing a fan tray in the Ruckus ICX 7750 should take less than two m...

Страница 68: ...uing 5 Holding the fan tray level guide it into the carrier rails on each side and gently push it all the way into the slot ensuring that it firmly engages with the connector 6 When you are sure the fan tray has properly engaged the connector tighten the captive screw to secure the fan tray in the slot NOTE The fans are controlled automatically by the device 7 Verify correct installation by runnin...

Страница 69: ...iller panel 3 Before opening the package that contains the new expansion module touch the bag to the switch casing to discharge any potential static electricity It is recommended that you wear an ESD wrist strap during installation 4 Remove the expansion module from the anti static shielded bag NOTE Do not force the installation If the expansion module does not slide in easily ensure that it is co...

Страница 70: ...68 Ruckus ICX 7750 Switch Hardware Installation Guide Part Number 53 1003900 10 Managing the Ruckus ICX 7750 Replacing an expansion module ...

Страница 71: ...ly of each other Power for each of the SFP sockets and for the adaptor is provided via the Twinax connections so no external power supply is required FIGURE 43 LRM adaptor module The LRM adaptor module is shipped with either one or two LRM optics 10G SFPP LRM depending on the model purchased LRM module part numbers 1 Port 1 4 10G LRM cages 2 Port 2 5 Adaptor body 3 Passive cable 280 mm TABLE 25 LR...

Страница 72: ...module requires software release 8 0 61 or later to be installed on the host switch ICX platform support for the LRM module NOTE On the ICX7750 48F the connections must be distributed across the SFP ports as follows Maximum three LRM modules on ports 1 1 1 to 1 1 32 Maximum three LRM modules on ports 1 1 33 to 1 1 48 Unpacking the LRM module When unpacking the LRM adaptor verify that the contents ...

Страница 73: ...ch Hardware Installation Guide 71 Part Number 53 1003900 10 Ruckus LRM Adaptor Module Unpacking the LRM module One or two 10G SFPP LRM optics depending on the model purchased China RoHS Hazardous Toxic Substance statement ...

Страница 74: ...72 Ruckus ICX 7750 Switch Hardware Installation Guide Part Number 53 1003900 10 Ruckus LRM Adaptor Module Unpacking the LRM module ...

Страница 75: ...egulatory compliance safety 78 Regulatory compliance environmental 78 System specifications Ethernet System component Description Enclosure 1U stackable chassis mountable in a standard 2 or 4 post rack Power supplies Dual redundant hot swappable 504 W AC or DC with intake or exhaust airflow Fans Four redundant hot swappable fan units with intake or exhaust airflow Cooling Forced air cooling front ...

Страница 76: ...ht ICX 7750 26Q 4 37 cm 1 72 in 44 00 cm 17 32 in 40 64 cm 16 00 in 5 60 kg 12 30 lb 8 80 kg 19 40 lb ICX 7750 48F 4 37 cm 1 72 in 44 00 cm 17 32 in 40 64 cm 16 00 in 5 90 kg 13 00 lb 9 10 kg 20 10 lb ICX 7750 48C 4 37 cm 1 72 in 44 00 cm 17 32 in 43 10 cm 16 97 in 7 00 kg 15 40 lb 10 20 kg 22 50 lb Condition Operational Non operational Ambient temperature ICX 7750 26Q 5º to 50ºC 23º to 122ºF ICX ...

Страница 77: ... Maximum output power rating DC Input voltage Input line frequency Maximum input current Input line protection Maximum inrush current RPS9 504 W 100 240 VAC nominal 100 264 VAC range 50 60 Hz nominal 47 63 Hz range 7 A Line fused 30 A peak cold or warm start for 10 ms 10 A peak for cycles 10 ms 150 ms Less than fuse rating for 150 ms RPS9DC 504 W 48 VDC nominal 40 to 60 VDC range NA 15 A Ve fused ...

Страница 78: ...igh speed ICX 7750 48C 558 W 1904 BTU hr 586 W 2000 BTU hr 586 W 2000 BTU hr 1 AC or DC Fans at high speed Module name Module description Power consumption ICX 7750 6Q 6 port 10 40 GbE QSFP Typical 18 8 W Maximum 25 9 W Model Port type Number of ports Description ICX 7750 26Q 40 GbE 26 QSFP 10 40 Gbps compatible with short range SR and long range LR optical SFP transceivers ICX 7750 48F 40 GbE 6 Q...

Страница 79: ...CE mark Immunity for Information Technology Equipment ICES 003 Canada Class A AS NZ 55022 Australia Class A VCCI Japan Class A EN 61000 3 2 EN 61000 3 3 EN 61000 6 1 Pin Signal Description 1 Not supported N A 2 Not supported N A 3 UART1_TXD Transmit data to ICX 4 GND Logic ground 5 Not supported N A 6 UART1_RXD Receive data from ICX 7 Not supported N A 8 Not supported N A Parameter Value Baud 9600...

Страница 80: ...ce in electrical and electronic equipment EU RoHS 2012 19 EU Waste electrical and electronic equipment EU WEEE 94 62 EC packaging and packaging waste EU 2006 66 EC batteries and accumulators and waste batteries and accumulators EU battery directive 1907 2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration Evaluation Authorisation and Restriction of Che...

Страница 81: ...may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE Changes or modifications made to this device which are not expressly approved by Ruckus could void the user s authority to operate the equipment Industry Canada st...

Страница 82: ...t based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions Korea English translation of above statement Class A device Broadcasting Communication Device for Office Use This device obtaine...

Страница 83: ...ber 53 1003900 10 Ruckus ICX 7750 Regulatory Statements China China English translation of above statement This is a Class A product In a domestic environment this product may cause radio interference inwhich case the user may be required to take adequate measures ...

Страница 84: ...olybromin ated diphenyl ethers PBDE 朅૨ߡ佊ў PCBAġ 梏۳ FAN ށ 䒠 Heatsink 㷬㼴 Chassis 佊ՠ俠 Cable ass y 朅 㚙 Power Supply ৰIJį澹 ӟıįIJġŸŵġĦ澺Ճ澹 ӟıįıIJġŸŵġĦ澺 ܶஒऀ 巡Фघӣࡁխ ӟघӣࡁխ ׂ䆯қ澞ġ ৰijį澹 澺 ܶ实柾ஒऀ 巡Фघӣࡁխ ߌ ӟघӣࡁխ ׂ䆯қ澞ġ ৰĴį澹 澺 ܶ实柾ஒऀ 巡䎹 ஔ柾ऩ澞ġ Declaration of the Presence Condition of the Restricted Substances Marking Equipment name Type designation Type Restricted substances and its chemical symbols Note 1烉 Exceeding 0 ...

Страница 85: ...ind nur zur Installation in Sperrbereichen bestimmt Ein Sperrbereich ist ein Ort zu dem nur Wartungspersonal mit einem Spezialwerkzeug Schloss und Schlüssel oder einer anderen Schutzvorrichtung Zugang hat Er unterliegt außerdem der Kontrolle durch die für den Standort verantwortliche Stelle MISE EN GARDE Tous les équipements dotés d un bloc d alimentation en courant continu Ruckus ICX 7750 sont co...

Страница 86: ...he devices near the input power connectors VORSICHT Stromkreise Verdrahtung und Überlastschutz dürfen nicht durch das Gerät überbelastet werden Addieren Sie die Nennstromleistung in Ampere aller Geräte die am selben Stromkreis wie das Gerät installiert sind Somit können Sie feststellen ob die Gefahr einer Überbelastung der Versorgungsstromkreise vorliegt Vergleichen Sie diese Summe mit der Nennstr...

Страница 87: ...ntation et les tiroirs de ventilation sont étiquetés d une flèche verte avec un E ou d une flèche orange avec un I PRECAUCIÓN En el caso de dispositivos ICX 7750 asegúrese de que la dirección del flujo de aire de la unidad de alimentación se corresponda con la de la bandeja del ventilador instalada Los dispositivos de alimentación y las bandejas del ventilador están etiquetadas claramente con una ...

Страница 88: ...se de descargar la tensión acumulada en el cable tocando la superficie de conexión a tierra con los contactos eléctricos CAUTION For DC systems use grounding wire of at least 12 American Wire Gauge AWG The grounding wire should be attached to the DC input connector as shown in Figure 30 the other end connects to the building ground VORSICHT Für Gleichstromsystem verwenden Erdungskabel von mindeste...

Страница 89: ...s de remplacement de la pile par un modèle incorrect Débarrassezvous des piles usagées conformément aux instructions PELIGRO Riesgo de explosión si se sustituye la batería por una de tipo incorrecto Deshágase de las baterías usadas de acuerdo con las instrucciones DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over GEFAHR Stellen ...

Страница 90: ...talación requiere un cordón de corriente distinto al que se ha suministrado con el instrumento verifique que usa un cordón de corriente que venga con la marca de la agencia de seguridad que defina las regulaciones para cordones de corriente en su país Esta marca será su garantía de que el cordón de corriente puede ser utilizado con seguridad con el instrumento DANGER Laser radiation Do not view di...

Страница 91: ... 2020 CommScope Inc All rights reserved Ruckus Wireless Inc a wholly owned subsidiary of CommScope Inc 350 West Java Dr Sunnyvale CA 94089 USA www ruckuswireless com ...