4.2.8. Control
connector
RS-232 LOCAL- local interface
These DB-9 female connectors are used for external modem communication between
RU and EU and for local access to the RU part.
DB-9 Female
PIN
Assignment
1
Booster presence IN
2
RS232 Tx
3 RS232
Rx
4 n.c.
5 GND
6 n.c.
7 n.c.
8 Booster
presence
OUT
9 n.c.
figure 4-25 RS-232 connector
table 4-5 RS-232 connector, pin assignment
Connect the RS-232 cable (1.5 m, contained in delivery of EU) from the LOCAL port
of the RU to the CTRL1 port of the EU.
4.2.9. Control
connector RS-232 CTRL
This DB-9 female connector is used for external modem communication between RU
and EU.
DB-9 Female
PIN Assignment
1 Booster
presence
OUT
2 RS232
Rx
3 RS232
Tx
4 n.c.
5 GND
6 n.c.
7 n.c.
8
Booster presence IN
9
n.c.
figure 4-26 RS-232 connector
table 4-6 RS-232 connector, pin assignment
Connect the RS-232 cable (1.5 m, contained in delivery of EU) from the LOCAL port
of the RU part to the CTRL port of the EU.