4. Commissioning
MF0150A3A.doc
Manual for ION-M7P/17EHP
Page 25
8. Clean in the similar way the
connector of the connected cable.
Remove protective caps from the unit
connector first.
9. Remove metal chips and small
particles from the mating and inner
surfaces of the connector using
compressed air.
10. Continue with the winding area using
lint-free wipe drenched with isopropyl
alcohol.
11. Continue with the inside mating
surface of the inner ring.
12. Clean the outside surface of the
center pin.