User’s Manual for
Remote Unit ION™-M80/90/19P
Page 22
MF0133ABA.doc
3.2.4. Power Connection
Before connecting electrical power to the units, the system must be grounded as
described in the previous chapter.
Mains power must be connected at the mains connector of the unit (see chapter
).
The power supply plug is part of the delivery. The correct wiring of the power supply
plug is as follows:
figure 3-8 AC mains plug
figure 3-9 DC mains plug
For the AC power supply connection, a minimum cross section of 1.5 mm
2
is required and for the DC power supply connection, a minimum cross
section of 2.5 mm
2
is required. Each wire must observe the applicable
national regulations regarding loop impedance, voltage drop, and
methods of installation. Make sure to connect the correct voltage to the
unit.
)
Note: Do not connect or disconnect the power cord at the mains connector
while power is on. Turn off mains* power before connecting the
power cord at the Remote Unit, then, engage mains again.
*
Mains power must be interrupted with an external mains breaker. For the mains breaker, observe
the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e.
the external AC breaker should be 20 Amps max. for 120-Volt service or 16 Amps for 240-Volt
service.
For the DC power supply, observe the local regulations of the DC service provider.