![CommScope FL1000 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/commscope/fl1000/fl1000_user-manual_2643823006.webp)
ADCP-90-545 • Issue 4 • July 2016
Page 6
© 2016
CommScope
. All Rights Reserved.
2.2.2
Adapter Plates With Pigtails
Use the following procedure to install 6pak plates with pigtails in the 24-fiber termination/splicing
panel.
1. Remove the front cover and slide out the splice deck.
2. Thread the pigtails through the empty mounting slot and loop the pigtails around the
radius limiters in the chassis as shown in
Figure 4
.
11367-C
SLOT
RADIUS LIMITER
(4 PLACES)
PIGTAILS
END
TAB
6 PAK PLATE
(LOADED)
SPLICE
DECK
Figure 4. Installing 6pak Plates with Pigtails
3. Align the adapter plate tabs with the notches in the mounting slot as shown in
Figure 4
.
4. Slide the 6pak plate into the slot until it snaps in place.
5. Fan out the fibers and tie them to the radius limiter on the right rear side of the splice deck
as shown in
Figure 5
. To tie the fibers, use cord lacing.
6. Route the fibers to the splice tray. For an illustration of correct routing, refer to
subsection 3.4, Splicing
, below.