M0201AKB_uc
CommScope Era
™
High Power Carrier Access Point Installation Guide — Preliminary
© January 2019 CommScope, Inc.
Page 23
Installing a CAP H
Determine the Mounting Site
When deciding on a suitable mounting site, observe the following rules.
•
The CAP H is suitable for installation indoors or outdoors.
•
Use the weights listed in
to determine a site that can bear the weight of the CAP H that is being
installed, where:
–
The “Maximum Lift Weight” is the highest weight that must be lifted during installation. (An installer
should lift the CAP H components one at a time, not a wholly configured CAP H.)
–
The “Total Hanging Weight” is the weight of the CAP H, including the weight of the Mounting Bracket,
minus the weight of the external cables and connectors, that the mounting site must be able to
support.
Table 7.
Maximum CAP H Installation Weights
CAP H installed with this option …
Maximum Lift Weight Total Hanging Weight
Mounting Kit
Part Number kg
lbs.
kg
lbs.
Pole
7661538
29
63.93
31
68.3
Wall
7661581
29
63.93
31
68.3
•
and
to determine the mounting site.
Table 8.
Key Description
Key Description
1
Minimum 198 mm (7.8”)
12
Minimum free space is 100 mm (3.94”) with OCTIS Kit
2
Minimum 75 mm (2.95”)
13
Minimum free space is 220 mm (8.66”) with Protective Tube Kit
3
O 12.5 mm (.5”)
14
824 mm (32.44”)
4
Power IN cable
15
782 mm (30.79”)
5
R45 min.
16
176 mm (6.93”)
6
OCTIS Kit
17
Free Area for Airflow IN: A AIR/IN .30000 mm
2
7
Protective Tube Kit
18
20.2 mm (.80”)
8
Minimum R100mm (3.9”)
19
12 mm (.47”)
9
21.5 mm (.85”)
20
24 mm (.94”)
10
80 mm (3.15”)
21
125 mm (4.92”)
11
9 mm (.35”)