12
M6 bolt
17
Snap the hook
of maintenance
wire here
EMPTY BOX
13 16 14
7
Passive Antenna
16
18
8
15
14
13
19 20
M10 bolt
M12 bolt
M12 bolt
10
13
11
GAP
Do not hit the endcap of the passive antenna
during installation. Leave 5 mm gap between
two endcaps.
Step1 Assemble the EMPTY BOX
Step2 Mount the EMPTY BOX
assembly to the pole
AEKT EMPTY BOX installation
Store extra brackets for future use
If the brackets lost, purchase AEKTBKT
Pre-Assembly of pipe bracket
MAXIMUM TORQUE
M6
8.0N.m (6ft.lbs)
M12
58N.m (43ft.lbs)
639853
Page 2 of 4
www.commscope.com
© 2019 CommScope, Inc. All rights reserved.
Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information.