Insert the RED test lead to V
Ω
socket
and BLACK test lead to COM socket ,
and rotate function knob switch to
( ) setting.
De-energize the circuit
For continuity measurement by connecting
conductor or circuit with test leads. If
resistance is measured less than 40
Ω
, an
audible signal will sound and display will
show a resistance value. If circuit is open,
display will show “OL”.
NOTE: Do not attempt to measure
continuity with live circuit.
NOTE: Do not attempt to measure
more than 10A
NOTE: When measuring currents
greater than 5A, a measurement time
of 30seconds follower by 15 minutes
of recovery time is recommended.
For mA DC Current less than 200mA,
Insert the RED test lead to V
Ω
socket
and BLACK test lead to COM socket ,
and rotate function knob switch
to the highest mA DC setting (200mA).
DC Current less than 200mA
DC Current 200mA to 10A
C
D
B
D
C
D
B
B
For 10A DC current with more than 200mA
but less than 10A, Insert the RED test lead
to 10A socket and BLACK test lead to
COM socket , and rotate function knob
switch to 10A DC setting (10A).
Red Test Lead
Black Test Lead
B
Red Test Lead
Black Test Lead
B
Red Test Lead
Black Test Lead
B
E
1-888-526-6193