G8-S0/G3-S0-I
Network Functions
1.1/1010
21
Example: ICX Messages only from Main Intercom Server
When conversations are built up in the sub-Intercom Server, no messages are sent to the ComWIN-
system
no telephone connection is charged. Only if a control desk in the sub-Intercom Server is
transferred to the main Intercom Server (or at call requests to the main Intercom Server), a connection
is built up.
Configuration Main Intercom Server
“Configuration Block”: 00
at: “Intercom Server” - “General Settings”
“No. - Block 1”: 90
“Nr. - Block 2”: 92
“Intercom Server - Block 1”: 90
at: “Interfaces” - “Gx-S0” - “1 - GE 800”
“Controldesk-system”: 90
at: “Intercom Server - Block 00” - “General”
“ICX”: 92
Configuration Sub Intercom Servers
“Configuration Block”: 99
at: “Intercom Server” - “General Settings”
“No. - Block 1”: 90
“Intercom Server - Block 1”: 90,
“Intercom Server - Block 2”: 92
at: “Network” - “Gx-S0” - “n - GE 300”
“Controldesk-system”: 90
at: “Intercom Server - Block 99” - “General”
“ICX”: GEV / CNET
ComWIN
GE 800 1
GE 300
2
GE 300
4
ISDN
GE 300
3
Control desk block number: 90
ICX block number: NET/CNET
Config. Block: 00
Sub Intercom Servers
Main Intercom Server
Config. Block: 99
Own block number: 90
Other block number: 90, 92
Control desk block number: 90
ICX block number: 92
Own block number: 90, 92
Other block number: 90
Содержание C-G3-S0-I
Страница 1: ...G8 S0 G3 S0 I VERSION 1 1 1010...