background image

TP–6/12AC

Installation manual

Cautions for installation

Troubleshooting

1. Installation tools & parts : Nipper, Screw driver, UTP cable(Cat 5.E) 
2. Products : TP-6/12AC , RF-1A
3. Wiring & setting method
3-1. Place the TP-6AC(12AC) upside down on the target place like [Picture 1]
3-2. Tighten the 4 screws with a proper screw driver 

 Connect wires like [Picture1] 

 

 Be sure not to change the sequence of wires.  

3-3. After finishing connecting wires, tighten the screws.

3-4. Connect wires of “RF-1A” to the products, No.1 with “+”wire, No.2 with “-“wire. Like [Picture 2]
4. Number Setting

4-1. The first, second and third connected products can be set by switch up at DIP switch of each product like [Picture 3]

  

- DIP switch setting & wiring for other extension units, refer to user manual.

 

* “V/R” S/W is for bell sound volume control.

 

* “P”S/W is the function to talk without picking up the phone when interphone receive a call from other interphone 

 

   which is working with [Broadcasting] button 

1. Total connected cable length shouldn’t be over 500M between first & last product (0.65m/m)

2. Be sure not to change the wiring sequence.

1. A voice through the phones feels quite low or they are not working at all.
   

Test the interphones with short wires than normal or connected 1 more power source.

2. It doesn’t make a call to the targeted interphone
   

Check setting of DIP switches after turn it all down

3. A user can hear the voice coming from other connected products.
   

It is a sign of working properly. Conference call is supported.

RF-1A

[ Picture 2 ]

[ Picture 1 ]

[ Picture 3 ]

Отзывы: