Commax DRC-GUM/RF1 Скачать руководство пользователя страница 35

34

19. Registration of Household Unit Number 

P - Management Password - E - 15 - E - Call Security from the monitor.- number of

household - E - serial number - E 

This method applies to the case that there is no security station installed. Calling

security from the monitor will direct the call to the lobby phone. Household Unit Number
can be set at the lobby phone.  

Содержание DRC-GUM/RF1

Страница 1: ...esponsible for any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety be...

Страница 2: ...tion of Household Unit Number 34 20 Checking Videophone Status of Household Units 36 21 Setting the Keypad LED Option 38 22 Activation of Electronic Key Password Function 39 23 Setting the Volume of V...

Страница 3: ...or it may cause an electric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the soc...

Страница 4: ...e power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the d...

Страница 5: ...mp 3 Speaker 4 OLED Display 5 RFID card receiver Name Searching button Menu Page Button 7 Program Button 8 Call Button 9 Number button 10 Cancel Button 11 C MIC 12 Electric Key Button 13 Extension Por...

Страница 6: ...LED display RF ID Receiver Optional When open door by wireless card key please tag it to this points See bellow photo Open door message and Icon will be displayed in OLED Call Button E Press Call unit...

Страница 7: ...cancel function press it Reset button Reset security guard password or management office password When forgot password press reset button which is on back side of products 15 Press Hold over 3 sec aft...

Страница 8: ...is forgotten 2 1 Password for any household Use the identifying household password function 6 1 to confirm the password methods to confirm password shall be requested to the Management office or Secu...

Страница 9: ...or the Manager Password is 4321 4 2 Password for any buildings Building Password A common password for a corresponding building Factory default for the Building Password is 1234 4 3 Password for any h...

Страница 10: ...Press management Password P old Password E New Password E Password must be 4 digits 0000 1234 4321 can t be used as Password Press program button P Press old management default Password 4 3 2 1 Press...

Страница 11: ...ust be 4 digits 0000 1234 4321 can t be used as Password Press program button P Press old building default Password 4 3 2 1 Press call button E Press 1 Set up building Password button Press call butto...

Страница 12: ...t be changed because of Interphone types Some model of Interphone can change Password in house Please check manual of interphone Press program button K Press 20 Set unit Password Number Press call but...

Страница 13: ...rd P management Password E 16 E Household Unit Number E Press program button P Press management Password Press call button E Press 16 Set ID Number function key Press call button E Press new ID Number...

Страница 14: ...ty guard Max 99 lobby panel can be installed for one building 7 1 Set building Number in Lobby panel interphone P Management Password E 2 E Building Number E Press program button P Press management Pa...

Страница 15: ...nel P Management Password E 3 E ID E Press program button P Press management Password Press call button E Press 3 Set ID Number function key Press call button E Press new ID Number Press call button E...

Страница 16: ...nly for the test of wireless card key Press down the P button Press Management Passwords Press Call Button E Press number 9 for the test of wireless card key Press Call Button E The card registration...

Страница 17: ...16 References Up to 2048 cards can be registered if not to connect with SecuMAX 8 2 RF card key input way P Management Password E 10 E Place card close to the RF ID receiver X cancel...

Страница 18: ...12 E Delete cards X Cancel Press Program Button P Press Management Password Press Call Button E Press number 12 separate delete number Press Call Button E Place the card key close to the RF ID receiv...

Страница 19: ...ion number E X Cancel Press Program Button P Press Management Password Press Call Button E Press number 12 separate delete number Press Call Button E Input the identification number you want to delete...

Страница 20: ...ord E 13 E Check the cards X Cancel Press Program Button P Press Management Password Press Call Button E Press number 13 registration check Press Call Button E Place the card key close to the RF ID re...

Страница 21: ...ress down P button Press Management Password Press down E button Press number 11 all delete number Press Call Button E Press Call Button E one more The number on OLED display to be changed Press down...

Страница 22: ...assword E 19 E 1 E Unlimited RF Cards can be registered Press down P button Press Management Password Press down E button Press number 19 capacity change number Press Call Button E Select mode between...

Страница 23: ...number 32 for data transmission Press Call Button E Press number destination lobby phone number Press Call Button E References Data can be sent only if the mode 99 in the program number 23 is selected...

Страница 24: ...mber 33 for data reception Press Call Button E Press number source lobby phone number Press Call Button E References Data can be received only if the mode 99 in the program number 23 is selected execu...

Страница 25: ...call number Press Program Button P Press Management Passwords Press Call Button E Press number 4 Program Number Press Call Button E Enter the Household number Press Call Button E If you want to set ot...

Страница 26: ...Forwarding to SecuMAX enabled This function is to set the door release by internal sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E for ca...

Страница 27: ...urs Press Program Button P Press Management Passwords Press Call Button E Press number 5 for door opening hours setting Press Call Button E Select door opening hours Opening hours is in the middle of...

Страница 28: ...line ex In case 1 line 2 line input 0102 This function is only for specified line call not for entire house call Press Program Button P Press Management Passwords Press Call Button E Press number 21 f...

Страница 29: ...function is to set the recall sound of house guard station at the common entrance Press Program Button P Press Management Passwords Press Call Button E for call Press number 7 for selection of call to...

Страница 30: ...25 E 1 E 1 time Call ring enabled This function sets number of call ring repetition when a call is made to any households or security office Press Program Button P Press Management Password Press Call...

Страница 31: ...Forwarding to SecuMAX enabled This function is to set the door release by internal sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E for ca...

Страница 32: ...E 29 E 1 E Forced opening by SecuMAX disabled This function is to set the opening the Main Entrance door forced opening by SecuMAX Press Program Button P Press Management Passwords Press Call Button E...

Страница 33: ...n 6 wire method If common 6 wire method selected there will be no video signal sent to all household units Press Program Button P Press Management Password Press Call Button E Press 6 number six Press...

Страница 34: ...word E 8 E 1 E Long distance transmission Factory default is set as short distance transmission Press Program Button P Press Management Password Press Call Button E Press 8 number eight Press Call But...

Страница 35: ...Call Security from the monitor number of household E serial number E This method applies to the case that there is no security station installed Calling security from the monitor will direct the call...

Страница 36: ...mbers can be registered As unit number registration is done press Cancel Button X to exit References Master videophone s Multi Sub Number is number 0 zero Sub videophone s Multi Sub Number is given be...

Страница 37: ...36 20 Checking Videophone Status of Household Units P Management password E 14 Unit Number E serial number E This function is to check the status of videophones installed in each household unit...

Страница 38: ...ther unit status repeat 6 7 procedures As the status check is done press Cancel Button X to exit Status of household unit indication Standby standby mode applies even when the household unit monitor i...

Страница 39: ...keypad LED ON OFF Press the program button P Please set up the Management password Press the call button E Press number 20 setting number of Electronic key Press the call button E Select mode by numbe...

Страница 40: ...ment Password E 31 0 E Electronic Key Password disabled This function is to enable or disable the password access Press Program Button P Press Management Password Press Call Button E Press 31 number t...

Страница 41: ...tion enables the adjustment of Beep Voice volume Press Program Button P Press Management Password Press Call Button E Press 30 number thirty Press Call Button E Press desirable Beep Volume 1 2 and the...

Страница 42: ...34 setting number of caller name Press Call Button E Press number destination lobby phone number Press Call Button E References Data can be send only if the mode 99 in the program number 23 is select...

Страница 43: ...ber 35 setting number of name data Press Call Button E Press number source lobby phone number Press Call Button E References Data can be received only if the mode 99 in the program number 23 is select...

Страница 44: ...Password E 36 E Module ID E Setting the data P This function is to set household data of the video floor distributor or CDV converter when it is installed Please Refer to the manual of the video floor...

Страница 45: ...the Searching Button S Press Call Button E If you want to move page Press the Electric Key K Button Setting the other number Repeat procedures Press Program Button P after finish to set all number Pl...

Страница 46: ...Management Password E 36 E Module ID E Setting the data P This function is to set household data of the audio floor distributor when it is installed Please Refer to the manual of audio floor distribut...

Страница 47: ...ber Repeat procedures Press Program Button P after finish to set all number Please wait to complete upload References It s able to set the DTMF setting value when audio floor distributors with DTMF fu...

Страница 48: ...s Call Button E 28 1 Setting the Door Release by Building Password P Management Password E 28 1 E Door release by Building Password enabled P Management Password E 28 0 E Door release by Building Pass...

Страница 49: ...48 28 2 Using a door release by Building Password function...

Страница 50: ...49 29 When you want to call a household 1 called to a household 2 Call by Extension panel button...

Страница 51: ...50 3 call by searching name...

Страница 52: ...51 30 When you want to call a Guard Station 31 Door Release by Unit Password...

Страница 53: ...Registration 2 P Management Password E 3 E Lobby Phone Number E Lobby Phone Number Registration 3 P Management Password E 28 E Door Release Function enabled disabled 00 Disabled 01 Enabled 4 P Manage...

Страница 54: ...Other settings 1 P Management Password E 5 E Door Release Duration Setting 2 P Management Password E 6 E Selecting Wiring Methods 04 Common 4 wires 06 Common 6 wires 3 P Management Password E 7 E Sele...

Страница 55: ...54 33 Wiring Information 1 Guard interphone GateView GuardStation 481 GuardStation...

Страница 56: ...55 2 Sensor connection method 3 Extension Panel Caution You can use DRC nUX n is the number of button for extending MAX 5 units...

Страница 57: ...56 4 Entrance interphone DRC GUM Caution If installed outdoor it requires extra molding for water proof and rainshield Recommanded height is pertinent from 1450mm 1500mm...

Страница 58: ...57 5 System schematic...

Страница 59: ...ctor 1 36 Specifications and Features Installation Flush Mount Type installation Model DRC GUM RF1 Gateview System UTP Cable Household unit monitor 8 wires common 6 wires video 2 wires Security statio...

Страница 60: ...tenna power range Under 47 5mV m within 10 meter radius Power DC 12V Emission Type A1D Number of Channel 1 Channel Modulation method ASK Communication method Simplex Operation Method Temperature 10 C...

Страница 61: ...60 Memo...

Страница 62: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2014 10 104 PM10GUMRF110...