background image

6

Cancel Button (X : Cancel) 

When user wants to cancel function, press it. 

Guard & Down Button (G : Guard) 

1) When Call a guard station, press it. 

2) Move Down(In Program Mode)  

Name searching button (S : Search) 

Tenants name searching button. 

Electric key & UP Button (K : Key) 

1) Open door by Password Number. 

(Deactivate Password LOCK function only.)  

2) Move Up(In Program Mode)

Содержание CMP-2BCT

Страница 1: ...any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a pr...

Страница 2: ...g 36 20 Registration of Household Unit Number 37 21 Checking Videophone Status of Household Units 39 22 Setting the Keypad LED Option 40 23 Activation of Electronic Key Password Function 41 24 Setting...

Страница 3: ...or it may cause an electric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the soc...

Страница 4: ...e power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the d...

Страница 5: ...3 1 The name of parts 3 Parts 4 NO Function NO Function 1 Camera 2 OLED Display 3 RFID card receiver Number Function Button 5 C MIC 6 Extension Port 7 Wire Connection Port 4...

Страница 6: ...bby phone Press the P program button hold over 5 seconds RF ID Receiver Optional When open door by wireless card key please tag it to this OLED display See bellow photo Open door message and Icon will...

Страница 7: ...d Down Button G Guard 1 When Call a guard station press it 2 Move Down In Program Mode Name searching button S Search Tenants name searching button Electric key UP Button K Key 1 Open door by Password...

Страница 8: ...orgotten 2 1 Password for any household Use the identifying household password function 6 1 to confirm the password methods to confirm password shall be requested to the Management office or Security...

Страница 9: ...responding building Factory default for the Building Password is 1234 4 3 Password for any household units Unit Password A password for each household unit can be set Factory default for the Unit Pass...

Страница 10: ...nded 5 1 Press management Password P old Password E 0 E New Password E Password must be 4 digits 0000 1234 4321 can t be used as Password Press Program Button P Press old management default Password 4...

Страница 11: ...ssword must be 4 digits 0000 1234 4321 can t be used as Password Press Program Button P Press old building default Password 4 3 2 1 Press Call Button E Press 1 Program Number Press Call Button E Press...

Страница 12: ...ay not be changed because of Interphone types Some model of Interphone can change Password in house Please check manual of interphone Press Program Button K Press 20 Program Number Press Call Button E...

Страница 13: ...1 Check house Password P management Password E 16 E Household Unit Number E Press Program Button P Press management Password Press Call Button E Press 16 Program Number Press Call Button E Press house...

Страница 14: ...tically are set up when lobby panel Call house and security guard Max 99 lobby panel can be installed for one building Press Program Button P Press management Password Press Call Button E Press 2 Prog...

Страница 15: ...bby Panel P Management Password E 3 E ID E Press Program Button P Press management Password Press Call Button E Press 3 Program Number Press Call Button E Press new ID Number Press Call Button E ID Nu...

Страница 16: ...to set the option to call household using Direct Call number Press Program Button P Press Management Passwords Press Call Button E Press number 24 Program Number Press Call Button E Select mode betwee...

Страница 17: ...number Press Program Button P Press Management Passwords Press Call Button E Press number 4 Program Number Press Call Button E Enter the Household number Press Call Button E If you want to set other d...

Страница 18: ...nction is only for the test of wireless card key Press Program Button P Press Management Passwords Press Call Button E Press number 9 Program Number Press Call Button E The card registration number wi...

Страница 19: ...18 10 2 RF card key input way P Management Password E 10 E Place card close to the RF ID receiver X cancel References Up to 2048 cards can be registered if not to connect with SecuMAX...

Страница 20: ...ord E 12 E Delete cards X Cancel Press Program Button P Press Management Password Press Call Button E Press number 12 Program Number Press Call Button E Place the card key close to the RF ID receiver...

Страница 21: ...fication number X Cancel Press Program Button P Press Management Password Press Call Button E Press number 12 Program Number Press Call Button E Input the identification number you want to delete Pres...

Страница 22: ...assword E 13 E Delete cards X Cancel Press Program Button P Press Management Password Press Call Button E Press number 13 Program Number Press Call Button E Place the card key close to the RF ID recei...

Страница 23: ...Press down P Button Press Management Password Press down E Button Press number 11 Program Number Press Call Button E Press Call Button E one more The number on OLED display to be changed Press down X...

Страница 24: ...ent password E 19 E 1 E Unlimited RF Cards can be registered Press down P Button Press Management Password Press down E Button Press number 19 Program Number Press Call Button E Select mode between nu...

Страница 25: ...ess number 32 Program Number Press Call Button E Press number destination lobby phone number Press Call Button E References Data can be sent only if the mode 99 in the Program number 23 is selected ex...

Страница 26: ...number 33 Program Number Press Call Button E Press number source lobby phone number Press Call Button E References Data can be received only if the mode 99 in the Program number 23 is selected execut...

Страница 27: ...E 1 E Forwarding to SecuMAX enabled This function is to set the door release by internal sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E...

Страница 28: ...ening hours Press Program Button P Press Management Passwords Press Call Button E Press number 5 Program Number Press Call Button E Select door opening hours Opening hours is in the middle of 1 25 sec...

Страница 29: ...ied line ex In case 1 line 2 line input 0102 This function is only for specified line call not for entire house call Press Program Button P Press Management Passwords Press Call Button E Press number...

Страница 30: ...sound This function is to set the recall sound of house guard station at the common entrance Press Program Button P Press Management Passwords Press Call Button E for Call Press number 7 Program Numbe...

Страница 31: ...E 25 E 1 E 1 time call ring enabled This function sets number of call ring repetition when a call is made to any households or security office Press Program Button P Press Management Password Press Ca...

Страница 32: ...8 E 1 E Forwarding to SecuMAX enabled This function is to set door release by external sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E fo...

Страница 33: ...1 E Forced opening by SecuMAX enabled This function is to set the opening the Main Entrance door forced opening by SecuMAX Press Program Button P Press Management Passwords Press Call Button E for Cal...

Страница 34: ...6 wire method If common 6 wire method selected there will be no video signal sent to all household units Press Program Button P Press Management Password Press Call Button E Press 6 Program Number Pre...

Страница 35: ...Password E 36 E Module ID E Setting the data P This function is to set household data of the video floor distributor or CDV converter when it is installed Please Refer to the manual of the video floor...

Страница 36: ...Press the Up K Down G Button Setting the other number Repeat procedures Press Program Button P after finish to set all number Please wait to complete upload References Data can be received only if the...

Страница 37: ...ord E 8 E 1 E Long distance transmission Factory default is set as short distance transmission Press Program Button P Press Management Password Press Call Button E Press 8 Program Number Press Call Bu...

Страница 38: ...Call Security from the monitor number of household E serial number E This method applies to the case that there is no security station installed Calling security from the monitor will direct the call...

Страница 39: ...mbers can be registered As unit number registration is done press Cancel Button X to exit References Master videophone s Multi Sub Number is number 0 zero Sub videophone s Multi Sub Number is given be...

Страница 40: ...39 22 Checking Videophone Status of Household Units P Management password E 14 Unit Number E serial number E This function is to check the status of videophones installed in each household unit...

Страница 41: ...ther unit status repeat 6 7 procedures As the status check is done press Cancel Button X to exit Status of household unit indication Standby standby mode applies even when the household unit monitor i...

Страница 42: ...is to set keypad LED ON OFF Press the Program Button P Please set up the Management password Press the Call Button E Press number 20 Program Number Press the Call Button E Select mode by numbers 0 or...

Страница 43: ...ement Password E 31 0 E Electronic Key Password disabled This function is to enable or disable the password access Press Program Button P Press Management Password Press Call Button E Press 31 Program...

Страница 44: ...ion enables the adjustment of Beep Voice volume Press Program Button P Press Management Password Press Call Button E Press 30 Program Number Press Call Button E Press desirable Beep Volume 1 2 and the...

Страница 45: ...s number 34 Program Number Press Call Button E Press number destination lobby phone number Press Call Button E References Data can be send only if the mode 99 in the Program number 23 is selected exec...

Страница 46: ...Press number 35 Program Number Press Call Button E Press number source lobby phone number Press Call Button E References Data can be send only if the mode 99 in the Program number 23 is selected execu...

Страница 47: ...Management Password E 36 E Module ID E Setting the data P This function is to set household data of the audio floor distributor when it is installed Please Refer to the manual of audio floor distribut...

Страница 48: ...er Repeat procedures Press Program Button P after finish to set all number Please wait to complete upload References It s able to set the DTMF setting value when audio floor distributors with DTMF fun...

Страница 49: ...n enables the door release by Building Password This function provides least security to the access of the entrance since the password is being shared among number of people Please keep the security i...

Страница 50: ...49 29 2 Using a door release by Building Password function...

Страница 51: ...50 30 When you want to Call a household 1 Called to a household 2 Call by Direct call number If Program 24 is set by 0...

Страница 52: ...51 If Program 24 is set by 1 3 Call by searching name...

Страница 53: ...52 31 When you want to Call a Guard Station 1 Call by Searching name 2 Call by Guard Button...

Страница 54: ...53 32 Door Release by Unit Password...

Страница 55: ...ement Password E 28 E Door Release Function enabled disabled 00 Disabled 01 Enabled 4 P Management Password E 31 E Electronic Key Password enabled disabled 00 Disabled 01 Enabled RF Card Key Programmi...

Страница 56: ...LL 4 P Management Password E 8 E Setting Video Out Impedance 00 Short range 01 Long range 5 P Management Password E 20 E Setting the Keypad LED Option 00 Only work when you used lobby phone 01 Always...

Страница 57: ...56 34 Wiring Information 1 Guard interphone GateView Guard Station 481 Guard Station...

Страница 58: ...57 Sensor connection method Extension Panel Caution You can use both 2 and 4 rows panel CMP 2BX 4BX for extending but can t use together MAX 5 units...

Страница 59: ...58 Entrance interphone CMP 2BCT 4BCT System schematic...

Страница 60: ...ed height is pertinent from 1450mm 1500mm Item Description Q ty CONN 2PX300 Wiring Connector 1 CONN 3P 3 96 X250 Wiring Connector 1 CONN 3PX300 Wiring Connector 2 CONN 4PX300 Wiring Connector 1 CONN 1...

Страница 61: ...l 15 735KHz 60Hz Scanning Frequency 15 625KHz 50Hz Imaging Angle Horizontal 62 degrees Vertical 46 degrees Lowest Intensity of Illumination Effective Call Range UTP CAT 5e 300m RF Sensing Range 30mm L...

Страница 62: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2015 10 104 PM982BCT4B10...

Отзывы: