6.  Specification

Building Distributor 5 Wire (Polarized cable) , CCTV 4 Wire (Polarized cable) 
(RJ45 CAT5e Patch Cable) 

Power

DC 14V / 4A 
1. Designated CCTV 

CMD-104VU LINE1,2,3,4 

2. CMD-104VU OUT(Output)  

CMD-104VU IN (Expansion)

3. CMD-104VU OUT (Output)  

Building Distributor(CMD-101BU) 

1. CCTV  

CMD-104VU  

CMD-101BUCMD-404FU  

House unit Videophone : Max. 300m

2. CCTV  

CMD-104VU : Max. 50m

(Max. two CCTV Selector can be installed) 

Model

Spec

CMD-104VU (CCTV video selector)

Transmission type 

Distance

Cabling step 

10

Содержание CMD-104VU

Страница 1: ...s User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly The company is not responsible for any safety accidents caused by abnormal o...

Страница 2: ...1 1 Introduction 2 2 Important Safeguard 3 3 Product concept and function 4 4 Wiring diagram 5 5 ID Setting 5 6 Specification 10 Contents...

Страница 3: ...xpose the unit to rain or moisture This symbol is intended to alert the use to the presence of uninsulated dangerous Voltage within the product s enclose that may be of sufficient magnitude to constit...

Страница 4: ...mage to the appliance Any mounting of the manufacture s instructions and should use a mounting accessory recommended by the manu facturer Object and Liquid Entry Never push objects of any kind into th...

Страница 5: ...LINE1 4 to CCTV One CMD 104VU connect to Max CCTV 4 CMD 104VU can be installed to Max 2 two Total CCTV 8 Must reboot CMD 104VU after setting DIP SWITCH 8PIN CMD 104VU can be expanded Max 2 two Each de...

Страница 6: ...5 4 Wiring diagram...

Страница 7: ...6 VIDEO PHONE CMD 404FU CMD 101BU CMD 104VU CCTV UTP CABLE CAT 5e MAX 300m...

Страница 8: ...tion After setting power should be off and on for rebooting Each switch function No 1 LINE1 CCTV availability OFF Disable ON Able to use No 2 LINE2 CCTV availability OFF Disable ON Able to use No 3 LI...

Страница 9: ...et No 1 If there is extension device set No 2 for exten sion device Max two device can be connected Interface CCTV to designate Line then switch on If there is no connection switch off No 5 6 No use O...

Страница 10: ...9 ID Setting way when 7 8 Switch are ON OFF...

Страница 11: ...CTV CMD 104VU LINE1 2 3 4 2 CMD 104VU OUT Output CMD 104VU IN Expansion 3 CMD 104VU OUT Output Building Distributor CMD 101BU 1 CCTV CMD 104VU CMD 101BUCMD 404FU House unit Videophone Max 300m 2 CCTV...

Страница 12: ...MEMO 11...

Страница 13: ...12 MEMO...

Страница 14: ...Printed In Korea 2014 12 105 PM99104VU010 513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com...

Отзывы: