background image

1

Table of Contents

1. Greeting..............................................................................................................1
2. Warnings and caution.........................................................................................2
3. Parts and functions ............................................................................................4
4. Compositions .....................................................................................................5
5. Main menu..........................................................................................................6
6. Household setting (household No./ PIN / extension)..........................................7
7. Away mode setting  ............................................................................................8
8. Individual door talk   ...........................................................................................9
9. Guard station talk .............................................................................................11
10. Emergency function........................................................................................12
11. Telephone function(Telephone/Extension/Neighbor talk) ..............................13
12. Volume control(Receiving / calling / button tone) ...........................................14
13. EMS function (Device control)  ......................................................................15
14. Detoured call ..................................................................................................19
15. Delivery notice................................................................................................19
16. Guard security function  .................................................................................19
17. Wiring  ............................................................................................................21
18. Operation tips  ................................................................................................23
19. Attention when in use .....................................................................................24
20. Miscellaneous.................................................................................................24
21. Specifications .................................................................................................25

1. Greeting

Thank you for purchasing a COMMAX product  

Please, use the product after carefully reading this Manual 

This type of videophone can be used in apartments, villas and other buildings as a

multifunctional device with door opening, telephone conversation and guard station

control function

Содержание CDP-1020ID

Страница 1: ...responsible for any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety b...

Страница 2: ...Receiving calling button tone 14 13 EMS function Device control 15 14 Detoured call 19 15 Delivery notice 19 16 Guard security function 19 17 Wiring 21 18 Operation tips 23 19 Attention when in use 24...

Страница 3: ...tric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not using it fo...

Страница 4: ...e power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the d...

Страница 5: ...Cannot be used as Slave terminal In case if multiple video phone terminals are installed and the line of one terminal is busy other terminal can overtake the call In case if the line is busy and the...

Страница 6: ...GH1T 4X18 ZNW Screws for mounting PHM 3 X 6 ZnY Screws for main body 2P 3EA Connectors 6P 2EA Connectors 8P 1EA Connectors 12P 1EA Connectors 3P 1EA Connectors 4P 1EA Connectors Monitor CDP 1020ID Wal...

Страница 7: ...te control Secumax remote metering and control Device control Lighting Gas valve Boiler Security1 Burglar1 For setting Security1 Magnetic sensor Security2 Burglar2 For setting Security2 PIR sensor Del...

Страница 8: ...t shows setting menu of PIN after pressing House PIN icon Enter your preferable 4 digits and press for confirmation 3 Extension No setting It shows setting menu of extension No after pressing extensio...

Страница 9: ...wer block device in away mode Time setting for security sensor in away mode Value 0 90 sec available Setting delay time Sec You can choose delay time after activating away mode Security sensors get ac...

Страница 10: ...sitor image when you get call sound Call indication appears on the upper left of screen Press Talk icon or button to communicate Press Talk end icon to end communication You can make door open by pres...

Страница 11: ...PTZ function Caution PTZ function is available when you connect door camera having PTZ function only You should make power off and on when you change with PTZ based door camera Display setting It sho...

Страница 12: ...ds talking 2 Receiving a call from Guard It converts with Guard talk after calling sound You can press Talk icon and talk When you press Talk end icon it ends talking Volume control function You can c...

Страница 13: ...gency function Release icon shows up in case of pressing Guard Button and Door release button simultaneously for more than 3 seconds during emergency alarming You should check all the circumstances in...

Страница 14: ...n call to neighbor by entering building number press Bldg and house number press Rm Receiving a call It appears Neighbor mark on screen when a call comes from neighborhood and you can talk by pressing...

Страница 15: ...ound from Telephone Guard It controls receiving sound from Guard phone Individual door It controls receiving sound from individual door Neighbor It controls receiving sound from Neighbor Call sound It...

Страница 16: ...hts off Each device tab is shown automatically after product booting In case a device is not properly connected it does not appear In order to make sure device checking please make power on again If t...

Страница 17: ...tus of the assigned valve Individual valve close You can make the available valve close by pressing the switch located below All Gas valve close Press All Close icon to make all valves close 2 Gas con...

Страница 18: ...rature display It shows the desired temperature of the room It has 2 controllers basically you can check and control additional controllers by scrolling right and left sides Temperature control You ma...

Страница 19: ...y pressing Requesting remote metering data Water It shows Water usage Gas It shows Gas usage Electricity It shows Electricity usage Hot water It shows Hot water usage Heat It shows Heat usage 4 Remote...

Страница 20: ...aneously for more than 3 seconds during emergency alarming After checking properly the status of inhouse you may press Release button to deactivate the alarm and it makes alarm sound stopped from guar...

Страница 21: ...turned tonormalmode aslongasitisworkingproperly Besuretocheckthe doorclosed ornobodyisin IR sensorarea You can makesecurityandawaymodereleasedwhenitisinstopmode 5 Away mode setting After setting away...

Страница 22: ...GENCY_ALARM_BUTTON DEVICE DC_OUT 300mA CONV 1 CONV 2 GND DATA INT B VIDEO GND CONV 3 CONV VIDEO IN GND VIDEO OUT 485 B CONV VIDEO OUT 485 A GND SENSOR GND DC12V SENSOR GND DC12V LB_VD_CONT 485 B GND 4...

Страница 23: ...ther or security sensor 2 away mode will be deactivated Guard Guard station unit is connected with 8 wires Be sure to check the wire polarity before connecting wires Individual door Camera Individual...

Страница 24: ...camera to the place where there is no backlight Blurry screen Due to foreign substance on the lens Remove foreign substance with rug No call to guard station common lobby Appears DATA LINE out of orde...

Страница 25: ...ll 1 Pull the Power Plug from the AC receptacle 2 Wait 10 minutes 3 Plug the unit back in and try your procedure again Getting Help If you still can t correct an operating problem contact your dealer...

Страница 26: ...wires Power Source 14V 1 8A Communication HANDS FREE Display 25 65Cm 10 1 COLOR TFT LCD DIGITAL Telephone Ringer Call sound Door camera Chime 3 melody 2 times Guard station Melody Door camera 28m 0 5...

Страница 27: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2016 09 104 PM011020ID10...

Отзывы: