Remote controller

You can open the door with remote controller.(Remote controller model only)

Setting

Open the inner body’s 

battery cover, push the 

[Register] button 

shortly with “Beep” 

sound.

“Beep”

“Beep”

Push the [Register] or 

[Open] button on the 

Open 

Register

remote controller.

Push the [*] button, 

the registration will be 

completed with sound.

Note

If you add another remote controller, repeat No.2 before lamp of key is off.

(Register up to 5 pcs)

Warning! 

The registration will be canceled when you do not register any remote 

controller for 10 seconds after push the registration button. 

If you register new remote controller, old one will be deleted automatically.

Cancel

Open the inner body’s 

battery cover, push the

[Register] button 

shortly with “Beep” 

sound.

Push [0] button 

Push [*] button more 

than 5 seconds, all the 

remote controller will 

be deleted with sound.

Содержание CDL-30LR

Страница 1: ...urchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly The company is not respon...

Страница 2: ...ns for pin number electronic key It is easy to register the pin number up to 4 and you can also register the electronic key up to 30 ea Multiple volume control optional mute You can easily adjust the...

Страница 3: ...eed to replace all new alkaline batteries Don t impact on the device Don t use it for other purpose except digital door lock A S and please keep the product warranty Product warranty Don t put water i...

Страница 4: ...function Convenient functions Optional Setting the automatic locking Setting the manual locking Setting the sound temporary pause Setting the sound volume Setting the detection of RFID with automatic...

Страница 5: ...body Thickness 35mm 50mm 4 12 digit number combination Up to 4 pin number Up to 30 keys Alkaline AA battery 4 pcs LR6 1 5V AA size Alkaline battery Optional 72 degree 5 degree lat tested 62 degree 5...

Страница 6: ...for emergency power To use to register or change the pin number You can open the door with registered pin number You can open register the electronic key Light will be on with low power with warning...

Страница 7: ...osethedoorforinstallingsideofdoor Itcanlockthedoortodoorframe Itcanpreventtoshakethedoor Powerforoperationdoorlock Usinglockthedoorundermanualmode Usingopenorclosethedooratinside Youcanlockthedoorandi...

Страница 8: ...4 to 12 digits Set the pin number 4 to 12 digits button than the registration Push the Go to outside Outside Outside Warning Warning Note If you add the other pin number you repeat until turn off the...

Страница 9: ...eceiver in order You can hear the sound when you register each electronic key You can complete the registration when you close the cover of keypad or push the button on the keypad Warning If you add t...

Страница 10: ...once then you can hear Beep sound Check the light of key numbers Push the buttons for 5 seconds all the electronic keys will be deleted with the sound 5 sec Opening the door at outside No 1 Using pin...

Страница 11: ...ceiver You can hear the sound and open the door Locking the door at outside In the case of setting the automatic lock In the case of setting manual lock The door is locked automatically after 2 second...

Страница 12: ...you can open the door Warning Warning If the door is opened to the inside please do not install the devices Locking the door at inside No 1 No 2 Locking the door by automatic The door is locked automa...

Страница 13: ...al lock LED function When the door is unlocked under manual lock mode the LED will be blinking and LED will not be blinking when the door is locked Setting cancel the LED ON function Manual lock LED f...

Страница 14: ...body Enter the pin number and button twice Enter the 4 button the automatic door lock function will be operated Setting manual door lock This is the optional function to lock the door manually Settin...

Страница 15: ...can hear the operating sound in next time Setting the sound volume You can set the sound volume You can use this functions when the door is locked Setting You can set the sound volume with 7 different...

Страница 16: ...ll be activated with sound Touch the outer body s key Enter the pin number Push 1 button the automatic detecting function will be activated with sound Note Push button twice With automatic detecting t...

Страница 17: ...with sound Note If you add another remote controller repeat No 2 before lamp of key is off Register up to 5 pcs Warning The registration will be canceled when you do not register any remote controller...

Страница 18: ...e warning You can disable the warning if you remove the batteries enter the pin number or contact the electronic key It can t be disable if the temperature is high Warning If the inner body is exposed...

Страница 19: ...e battery replacement If you hear Beep Beep Beep sounds sound after operation normally you need to change the battery At this time you need to replace all the batteries for new one Beep Beep Beep Note...

Страница 20: ...e button the door will be unlocked with sound Emergency key Key type Only Note If you can t open the door because of malfunctions To remove the cover of emergency key to the left Input the emergency k...

Страница 21: ...you can t open the door Please push button to operate the device and enter the pin number once again The light of keypad will turn out automatically if you don t enter anything within 7 seconds Page...

Страница 22: ...Printed In Korea 2014 04 106 COMMAX CO Ltd 513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com...

Отзывы: