background image

10

1) When paging the household 

Enter the household number you want to cal.1

ex) household 101

1, 0, 1  

Household number appears on FND 

Press the Call button (E) 

Conversation begins when they answer. 

2) When paging guard station 

Press the guard button  

‘gUAd’appears on FND 

Press the Call button (E) 

Emit call house along with  flickering of ‘gUAd’.

Conversation begins when guard station answers. 

3) Opening the door with RF card  

Press the Household number 

Press the Key button (K) 

Letters of ‘PASS’ flicker on the FND.

Press the 4-digit password.   

Appears ‘----’ on the FND. 

Press the Call button 

Door is open with flickering of ‘oPEn’ on FND .

[Reference for use] 

Contact guard station or management station if you
don’t remember the password

Enter theHousehold Number.

Wait for a reply

Press the page button.

A paging tone will sound.

Press the 

Call button (E).

ex) unit 101

ex) To open the door of unit 101

Press the Guard button.

Press the Page button.

A paging tone will sound.

Wait for a reply

Press the Call button (E).

Enter the Household Number.

Press the Electronic key button.

Enter the Household PIN. Press the Page button.

Press the Call button (E).

Please the Card Here

OPEN DOOR

4) Opening the door with registered RF card (optional function) 

Put the RF card on the sensor positioned right below of
camera lens to open the door. Door will be opened along
with a message of ‘oPEn’ on FND. 

[Reference for use] 

1. If you try to open the door with unregistered RF

card, it will be notified to guard station. Please
try again after registering it at the guard station
or management office. 

2. If RF card still doesn’t work after proper

registering procedure, it is not usable card.

6. How to use lobby inter phone

Содержание CAV-70PG

Страница 1: ...sponsible for any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety bef...

Страница 2: ...roduct 1 Greetings 1 2 Safety Warning Caution 2 3 Part names functions 4 4 Operating 5 5 Configuration 6 6 How to use Lobby Inter Phone 10 7 Installing method 11 8 Wiring method 11 9 Contents 12 10 In...

Страница 3: ...or it may cause an electric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the soc...

Страница 4: ...e power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the d...

Страница 5: ...nd level max min Name 1 Monitor 10 Callvolumecontrol max min 2 Microphone 11 MENU menuswitch 3 Speaker 12 SELECT selectbutton 4 PowerindicatorLED 13 UPbutton 5 Monitoringbutton individualdoor 14 DOWNb...

Страница 6: ...e shown on the monitor with emitting chime sound when a visitor presses the call button Press the talk button by watching visitor and talk with a visitor Screen will be turned off after 60 sec automat...

Страница 7: ...you can hear the call sound of guard sound Conversation will begin when a guard station responds 4 Monitoring 1 In case both lobby and individual cameras are installed Click the monitor button once i...

Страница 8: ...after press the SELECT button move to RESET with button Press SELECT button to enter the menu Select YES on screen with button Press the SELECT button Caution Display setting and initializing function...

Страница 9: ...o HOME SET in the system set mode of 5 2 and after press the SELECT button move to HOME ID with button Press SELECT button Current building household is seen on the first screen Caution default value...

Страница 10: ...00 or 1234 4321 it will not be working 3 EXIT Return to System set mode of 2 How to set up Move to HOME SET in the system set mode 5 2 and after press the SELECT button move to EXIT with button Press...

Страница 11: ...Number Wait for a reply Press the page button A paging tone will sound Press the Call button E ex unit 101 ex To open the door of unit 101 Press the Guard button Press the Page button A paging tone w...

Страница 12: ...nstall it avoid the place where can be influenced by Magnetism Humidity Direct light and heater Screw T4 2EA Screw M3 Caution Keep out of direct sunlight or backlight Keep the lens cleaned DRC 40CK 7...

Страница 13: ...r switch with a safety device must be used in your building 4 Unplug before installing or repairing the product 5 Unplug when you connect monitor with door cameras Please carefully read this User s Gu...

Страница 14: ...tch circuit Display 17 78Cm 7 COLOR TFT LCD DIGITAL Entrance Electronic chime 3 tone melody 2 Guard station Melody Standby 30sec Conversation 60sec Guard station 3min Individual camera 28m 0 5 Distanc...

Страница 15: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2011 12 104 PM0270PG0011...

Отзывы: