Commax CAV-705U Скачать руководство пользователя страница 10

9

How to use door monitoring/talk and basic function 

1. Individual door monitoring and talk 

When you press 

Door

icon, it shows door monitoring 

When you press 

Talk

icon, it enables to talk 

When you press 

Door Release

icon, it makes door open

2. When you get a call from entrance(Individual/Lobby) 

It shows visitor image when you get call sound(Call indication appears on the upper left of

screen) 

Press 

Talk

icon(or button) to communicate. 

Press 

Talk end

icon to end communication

You can make door open by pressing 

Door Release

button while talking with visitor 

Volume control function 

You can control receiving sound volume t, - of volume control while talking 

You can control call sound volume t, - of volume control while monitoring 

(You can make factory default by pressing 

Initial

8. Individual door talk  

www.safemag.ru

www.safemag.ru

Содержание CAV-705U

Страница 1: ...r any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a...

Страница 2: ...ng button tone 14 13 EMS function Device control 15 14 Detoured call 19 15 Delivery notice 19 16 Guard security function 19 17 Wiring 21 18 Operation tips 23 19 Attention when in use 24 20 Miscellaneo...

Страница 3: ...when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not using it for a long period...

Страница 4: ...lease don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the designated conne...

Страница 5: ...as Slave terminal In case if multiple video phone terminals are installed and the line of one terminal is busy other terminal can overtake the call In case if the line is busy and the call comes to th...

Страница 6: ...POWER CORD 480 3P 1EA 4P 1EA MANUAL 6P 2EA 8P 1EA 12P 1EA 4 Compositions Monitor GH1T4X18ZNW Screwsformounting Screwsformainbody Connectors Connectors Connectors Connectors Connectors Connectors Wallb...

Страница 7: ...max remote metering and control Device control Lighting Gas valve Boiler Security1 Burglar1 For setting Security1 Magnetic sensor Security2 Burglar2 For setting Security2 PIR sensor Delivery For check...

Страница 8: ...menu of PIN after pressing House PIN icon Enter your preferable 4 digits and press for confirmation 3 Extension No setting It shows setting menu of extension No after pressing extension icon Call gua...

Страница 9: ...e in away mode Time setting for security sensor in away mode Value 0 90 sec available Setting delay time Sec You can choose delay time after activating away mode Security sensors get activated after d...

Страница 10: ...n you get call sound Call indication appears on the upper left of screen Press Talk icon or button to communicate Press Talk end icon to end communication You can make door open by pressing Door Relea...

Страница 11: ...aution PTZ function is available when you connect door camera having PTZ function only You should make power off and on when you change with PTZ based door camera Display setting It shows Color Contra...

Страница 12: ...ceiving a call from Guard It converts with Guard talk after calling sound You can press Talk icon and talk When you press Talk end icon it ends talking Volume control function You can control receivin...

Страница 13: ...gets emergency signal from household How to release emergency function You should check all the circumstances in your house after emergency happened and press Release icon to stop signal going to gua...

Страница 14: ...bor by entering building number press Bldg and house number press Rm Receiving a call It appears Neighbor mark on screen when a call comes from neighborhood and you can talk by pressing talk button Ho...

Страница 15: ...hone Guard It controls receiving sound from Guard phone Individual door It controls receiving sound from individual door Neighbor It controls receiving sound from Neighbor Call sound It controls calli...

Страница 16: ...vice tab is shown automatically after product booting In case a device is not properly connected it does not appear In order to make sure device checking please make power on again If the device is se...

Страница 17: ...gned valve Individual valve close You can make the available valve close by pressing the switch located below All Gas valve close Press All Close icon to make all valves close 2 Gas control Press EMS...

Страница 18: ...It shows the desired temperature of the room It has 2 controllers basically you can check and control additional controllers by scrolling right and left sides Temperature control You make the display...

Страница 19: ...esting remote metering data Water It shows Water usage Gas It shows Gas usage Electricity It shows Electricity usage Hot water It shows Hot water usage Heat It shows Heat usage 4 Remote control Press...

Страница 20: ...tus of inhouse you may press Release button to deactivate the alarm and it makes alarm sound stopped from guard station You can make it initial stage once you press Return button 2 Alarm 2 function Ga...

Страница 21: ...rity Press Release icon Return icon Caution Burglarsensorwillbereturnedtonormalmodeaslongasitisworkingproperly Besuretocheckthe doorclosedornobodyisinIRsensorarea Youcanmakesecurityandawaymodereleased...

Страница 22: ...T 6 LB_VD_CONT GND DC14V ALARM BUTTON PIR GAS ALARM1 FIRE 300mA LIGHTING GAS BOILER Diagram Installing SLAVE phones Enter the ID which is an assigned number of each Slave phone for classifying ID in c...

Страница 23: ...When it is used with security switch lead switch it use and sensor line If you do not want to use security 2 please connect sensor line each other or security sensor 2 away mode will be deactivated G...

Страница 24: ...lace where there is no backlight Blurry screen Due to foreign substance on the lens Remove foreign substance with rug No call to guard station common lobby Appears DATA LINE out of order 2 on the scre...

Страница 25: ...ower Plug from the AC receptacle 2 Wait 10 minutes 3 Plug the unit back in and try your procedure again Getting Help If you still can t correct an operating problem contact your dealer If your dealer...

Страница 26: ...E 0 3A Communication HANDS FREE Display 17 78Cm 7 COLOR TFT LCD DIGITAL Telephone Ringer Call sound Door camera Chime 3 melody 2 times Guard station Melody Door camera 28m 0 5 Distance Guard station 1...

Страница 27: ...daewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2014 05 104 PM02705U0010 www safemag ru www...

Отзывы: