background image

7/23/02 

ALA550   

4

This wire is the positive trigger input wire for positive door pin switch. This wire is connection for "positive" 
type factory door pins(typical FORD MOTOR). Locate the "common wire" for all door pins and make the 
connection of the Violet Wire here. 

H7/4. YELLOW WIRE – TO IGNITION SW12V    -- 

This wire is connected to a switched 12 volt source. This wire should receive "12 volt" when the ignition 
key is in the "ON" and "START" position. When the ignition is turned "OFF", this wire should receive "0" 
volt . 

H7/5. 

GREEN WIRE -- NEGATIVE DOOR SWITCH SENSING INPUT -- 

This wire is the ground trigger input wire for negative door pin switch. This wire is connection for 
"grounding" type factory door pins locate the "common wire" that connects the door pin switches. Make 
the connection of the GREEN Wire here. 

H7/6. ORANGE WIRE – (-) 200mA GROUNDED OUTPUT WHEN ARMED -- 

This wire will become grounded when the alarm is armed. The current capacity of this wire is 200mA. This 
output can control starter disable, when an intrusion is detected and the system is triggered. The vehicle 
prevent from any unauthorized starting.   

a). Find the wire from the starter solenoid, (usually located on the starter) and going to the ignition switch. 
b). When found, use voltmeter, connect one probe of the voltmeter to ground and connect the other end of 

the probe to the starter wire, it should receive "12 volt" only when the ignition key in the "START" 
position. 

c). After locating the correct wire, cut it in half, try to start the vehicle. The engine should not "crank over". 
d). When the extend wires are needed, they must be exactly same gauge as the cut wire. Connect the cut 

wire from the key switch to the RED wire (pin #30) of the relay, and connect the starter wire to the 
WHITE wire (pin #87a ) of the relay. 

e). Connect the ORANGE Wire from the control module to the ORANGE wire (pin #86) of the relay. 
NOTE: If more than one electronic device will be connected to the ORANGE Wire, it will be necessary to 
isolate the connection of each device control wires with a IN4003 diode. 
 

87

87a

85

30

86

IN4003 Diode

H7/6 Orange wire

“Start”

“On”

White wire

X

Cut

Red wire

Orange wire

“Acc”

“Off”

Starter

 

 

H7/7. BROWN WIRE – (-) 200mA 2 STEPS UNLOCK OUTPUT -- 

The 2 steps unlock feature will work for the most fully electronic door lock circuit. The vehicle must have an 
electronic door lock switch (not the lock knob or key switch), which lock and unlock all of vehicle's doors. 
When wired for this feature, press the disarm (or unlock) button one time will disarm the alarm and unlock 
the driver's door only. If, press disarm (or unlock) button two times within 3 seconds, the alarm will disarm 
and all doors will unlock. 
 

H7/8. PINK WIRE – (-) 200mA TIMER CONTROL CHANNEL 3 / HORN OUTPUT – 

TIMER CONTROL CHANNEL 3 OUTPUT 

(

Factory default setting

 on 

momentary ground

ed)

 

This wire is built-in user-programmable timer output provides a ground through this wire. Press the

 

 

 

  button on the transmitter. You may program the built-in timer to send a ground signal for any time 

interval between 1 second and 2 minutes. For instance, this timer output may be used to turn on the 
headlight with the remote control. Also on certain BMW, Mercedes Benz, Jaguar and Volkswagen cars, 
you can use this unique timed output to allow remote closure of all power window and sunroof without 
the need for an external module! (See Alarm Feature

 

III – 5

 

Programming) 

HORN OUTPUT (See Feature 

III – 5

 Programming) 

This wire is provided to use the existing vehicle's horn as the alarm system optional warning audible 
device. It's a transistorized low current output, and should only be connected to the low current ground 
output from the vehicle's horn switch. When the system is triggered, the horn will sound.   

 

Содержание ALA550

Страница 1: ...7 23 02 ALA550 1 COMMANDO MODEL ALA550 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION OPERATION INSTRUCTIONS...

Страница 2: ...e Wire Parking Light Relay Output Red White Wire Parking Light Relay input Or Horn Programmable H7 10 PIN MINI CONNECTOR WIRE HARNESS Green Wire Zone 3 Negative Door Pin Trigger Input Blue Wire Zone 2...

Страница 3: ...default setting This is the positive output connection for the siren Current capacity is 2 Amp Make connection to the red wire from the siren Make the black wire coming from the siren to a good chassi...

Страница 4: ...pin 87a of the relay e Connect the ORANGE Wire from the control module to the ORANGE wire pin 86 of the relay NOTE If more than one electronic device will be connected to the ORANGE Wire it will be ne...

Страница 5: ...rrent capacity of this wire is 200mA For optional electrical device in this system please connected to an additional relay I E Pager interface 87a 86 87 30 85 Fuse Gray Wire 12V Or Ground Depending On...

Страница 6: ...NNECTION FOR 5 WIRE ALTERNATING DOOR LOCKS 12V Cut the Existing Lock Wire Cut Existing Unlock Wire X Cut the Unlock Wire Lock Unlock OEM Door Master Lock OEM Slave Door Lock Switch 12V Lock Unlock To...

Страница 7: ...mitter until the siren responds with a confirming chirp the second transmitter is now programmed 3 Apply the same procedure to program 3rd and 4th Exit Turn Ignition to OFF position or leave it for 15...

Страница 8: ...tion controlled door unlock Without ignition controlled door unlock 5 Pathway illumination feature off Parking light on for 30 second upon an unlock signal Parking light on for 30 second upon an unloc...

Страница 9: ...IV PRORAMMING 1 Turn the Ignition switch ON OFF 3 TIMES and stay in OFF position 2 Push the Valet switch 8 times and hold it until four chirps and a long chirp is hearing then release the valet switch...

Страница 10: ...hin 15 seconds enter your chosen the second digit code by pressing and releasing the valet Switch from 1 9 times 5 Finish by turning the ignition switch to OFF position If the new password code was ac...

Страница 11: ...the proper sensitivity 4 c Test the Zone 1 Wireless PIR or Door Switch Press and release the transmitter button again 3 LED flash 3 siren horn chirps to indicate your are in optional wireless PIR or D...

Страница 12: ...ITION Siren Horn Parking Light LED Doors Starter Dome Light Pager 1 Arming 1 or 3 Chirps 1 Flash Slow Flash Locking Disable 2 Disarming 2 or 4 Chirps 2 or 3 Flashes Fast Flash or Off Unlocking Turns o...

Страница 13: ...ED will stop flashing It will begin flashing again once the vehicle all entrances are closed 3 After 30 second timer has elapsed the security system will automatically ARM The siren will chirp 1 time...

Страница 14: ...rps form siren horn 3 flash from parking light to indicate the system was disarmed J VALET MODE System in Disarm or Valet mode The valet switch allow you to temporarily bypass all alarm function elimi...

Страница 15: ...six full cycles the door will be bypassed until the trigger ceases N ANTI CAR JACKING Warning If you don t need the anti car jacking function in this alarm system be sure to set anti car jacking featu...

Страница 16: ...n the ignition switch off The system will automatically unlock the central locking system b Safety lock with ignition switch and handbrake Connect the black white wire to the handbrake switch for this...