Electrical Wiring
Please Note: Detailed internal wiring schematics are located at the back of this user guide.
Run the control wire from the control box holster to the
KNIGHT
2
.
Run the power wire from the breaker box or generator to the
KNIGHT
2
. A 20 Amp breaker
is recommended on AC models with LED fixtures.
Make the control connections in the
KNIGHT
2
relay box.
The standard model KL415A series
KNIGHT
2
comes pre-wired to connect to 120 VAC. It
is necessary to remove the jumper connecting the red and black terminals for 240 VAC
operation.
120 VAC
240 VAC
If 240 VAC operation is desired, remove the jumper wire between the red and black leads.