7
STEP 5
- Reassemble Exit Device
p
uSh
paD
c
aSe
B
racket
S
crewS
B
racket
h
eaD
cover
1
4
2
3
Replace bracket & attach (2) screws with
5/16 nut drive or flat head screw driver.
C.
Replace push pad by placing over
activating arms & pushing down then back
towards end of device.
A.
Slide baseplate back into case being
careful of motor wires.
B.
Replace mounting bracket.
D.
Replace head cover & (4) head cover
screws if present.
E.
Depress push pad, apply power & set PTS
adjustment.
Step 1
-
Select your preferred torque mode (ships in standard torque) Press the
device push pad to the desired setting.
(Recommend to fully depress
and release 5%, giving the device room for changing door conditions.)
Step 2
-
While depressing the push pad, apply power. (i.e. Presenting the
credential to the reader).
Step 3
-
Continue to keep pad depressed, the device will beep 6 times. After
the beeps have stopped, release the pad and now the adjustment is
complete. If not to your liking repeat the 3 steps.
S
etting
ptS
F.
Step 4
-
Once you found the correct location, flip the dip switches to off to lock programming.
ON
OFF
OFF
OFF
ON
OFF
Low Torque
Standard Torque
PTS programming locked
ON ON High Torque
1
S
witch
p
rogram
2