T E C H N I C A L   I N F O R M AT I O N

MM4S 

S

witcheS

2 Beeps

3 Beeps

5 Beeps

6 Beeps

B

eepS

e

xplanation

S

olution

Over Voltage

Under Voltage

Retraction or Dogging 

failure

Push to Set

> 30V unit will shut down. Check voltage & adjust to 24 V.

< 20V unit will shut down. Check voltage & adjust to 24 V. 

Device physically binding during retraction or pulled from the dogged position.

Device is recording it’s new position and power mode after the 6th beep.

t

rouBleShooting

 & D

iagnoSticS

4 Beeps

Failed Sensor

Verify all 3 sensor wires are installed correctly. Replace sensor if problem 

persists by contacting office.

S

etting

 ptS

Make sure to set PTS before finishing installation!

**

Important Info

**

•  Input Voltage:  24VDC +/- 10%

•  Wire gauge:  Minimum 18 gauge

•  Direct wire run - no relays or access control units 

in-between power supply & module

•  Average Latch Retraction Current:  2 Amp
•  Average Holding Current:  250 mA

High Torque Mode

•  Average Latch Retraction Current: 600 mA
•  Average Holding Current:  150 mA

Low Torque Mode

1.  After 1

st

 fail: 5 beeps then immediately attempts to retract again.

2.  After 2

nd

 fail: 5 beeps with pause in-between for 30 seconds then device 

attempts to retract again.

3.  After 3

rd

 fail: 5 beeps every 7 minutes, device will not attempt to retract.

To Reset: Depress bar for 5 seconds at any time.

ON

OFF

OFF

OFF
ON

OFF

Low Torque
Standard Torque

Programming locked

ON ON High Torque

1

S

witch

 

p

rogram

2

•  Average Latch Retraction Current: 900 mA
•  Average Holding Current:  215 mA

Standard Torque Mode- S

hipS

 S

tandard

S

pecificationS

Step 1

-

Select your preferred torque mode (ships in standard torque) Press the device push pad to the 
desired setting. 

(Recommend to fully depress and release 5%, giving the device a little room 

for changing door conditions.)

Step 2

-

 While depressing the push pad, apply power. (i.e. presenting the credential to the reader).

Step 3

-

 Continue to keep pad depressed, the device will beep 6 times. After the beeps have stopped, 
release the pad and now the adjustment is complete. If not to your liking repeat the three steps. 
That’s all there is to it. 

Step 4

-

 Once you found the right location, switch the dip switches to off to lock in programming.

rex S

witch

Rating:

 .5A @24VAC

 

Configuration:

G

reen

 - C

ommon

 (C)

B

lue

 - n

ormally

 o

pen

 (no)

G

ray

 - n

ormally

 C

losed

 (nC)

OPTIONAL