Compact Scaler Switcher
Comm-Tec S.r.l.
31
www.comm-tec.it
Command
Description
Command Example and
Feedback
>SetAutoCec [Param]
Set whether to automatically send CEC
commands after signal detection.
[Param] = EN, Dis
EN - Enable (Default)
Dis - Disable
>SetAutoCec EN
<AutoCec True
>GetAutoCec
Get whether to automatically send CEC
commands after signal detection.
<AutoCec True
>SetAutoCommand
[Param]
Set whether to automatically send RS232
commands after signal detection.
[Param] = EN, Dis
EN - Enable (Default)
Dis - Disable
>SetAutoCommand EN
<AutoCommand True
>GetAutoCommand
Get whether to automatically send RS232
commands after signal detection.
<AutoCommand True
>SetAutoStandby
[Param]
Enable/disable auto standby after no signal
detection. [Param] = EN, Dis
EN - Enable
Dis - Disable (Default)
>SetAutoStandby EN
<AutoStandby True
>GetAutoStandby
Get auto standby setting status.
<AutoStandby True
>SetAutoRelay [Param]
Enable/Disable auto power off function of
relay. [Param] = EN, Dis
EN - Enable
Dis - Disable (Default)
>SetAutoRelay EN
<AutoRelay True
>GetAutoRelay
Get auto power off setting status of relay.
<AutoRelay True
>SetPanelCEC [Param]
Set the delay time to send CEC, RS232 and
standby commands after removing input
signal removed.
[Param] = 0~1800 (s) (Default: 600s)
>SetPanelCEC 9
<PanelCEC 9
>GetPanelCEC
Get the delay time to send CEC, RS232 and
standby commands after removing input
signal removed.
<PanelCEC 9
>SetOffMsgLoopCnt
[Param]
Set the number of times of sending Display
Off command. [Param] = 1 ~ 2 (Default: 1)
>SetOffMsgLoopCnt 1
<OffMsgLoopCnt 1
>GetOffMsgLoopCnt
Get the number of times of sending Display
Off command.
<OffMsgLoopCnt 1
>SetOffMsgLoopDelayT
ime [Param]
Set the delay time of sending Display Off
command.
[Param] = 5 ~ 100 (1=100ms) (Default: 10)
>SetOffMsgLoopDelayTime
5
<OffMsgLoopDelayTime 5
>GetOffMsgLoopDelay
Time
Get the delay time of sending Display Off
command.
<OffMsgLoopDelayTime 5
>SetInputMsgDelayTime 10