27 of 38
5.5
RS-232 Function (RS-232 cable is optional)
Use the tool “Hyper Terminal” or other tools to control the ProPLAY HD with ASCII command.
NOTE.
1.Baud Rates:
- Firmware Updating: Set up the baud rate to 115200, 8,n,1.
- ASCII Command: The available baud rates is 38400, 8,n,1.
Commands end with a Carriage return (Hex 0D)
Use a Null-Modem cable (Crossover, female-female)
2. The reaction time of ProPLAY HD is around three seconds.
n
Keyboard Layout
q: POWER
-: VOL -
w: SLOW
R: RETURN
*: MUTE
>: NEXT
!: REPEAT
S: SELECT
<: PREW
~: SETUP
A: Auto Download
u: UP
#: TV MODE
p: PLAY
d: DOWN
%: AutoPlay
P: PAUSE/STEP
l: LEFT
i: INFO
x: STOP
r: RIGHT
m: NTSC/PAL
f: FFW
s: ENTER
$: SEARCH
b: REW
C: CLEAR
+: VOL +
(XXXXX.XXX): Play The File (xxxxx.xxx is the file name)
NOTE: Must include the round brackets.
[number]:
Action 1: Play the file by index (numbers < upper case letters < lowercase letter).
Action 2: Control the play button to execute the action (the file “playlist.ini” must be on the CF
card ).
n
Pin Assignment
D Sub 9Pin Female
D Sub 9Pin Female
Pin 1
Pin 4
Pin 2
Pin 3
Pin 3
Pin 2
Pin 4
Pin 1
Pin 5
Pin 5
Pin 6
Pin 6
Pin 7
Pin 8
Pin 8
Pin 7
Pin 9
Pin 9