4.3 Linking inputs (1-IN, 8-OUT switcher)

To perfom an 1-IN, 8-OUT switcher set the DIP-switches #3 (IN1+IN2) and #4 (IN1
75ohm) in ON position. Set the DIP-switch #2 (IN2 75ohm) in OFF position and
connect the input signal to the BNC IN1.

4.4 Linking inputs with T adapter

To perfom an 1-IN, 8-OUT switcher with loop-through feature set the DIP-switch
#3 (IN1+IN2) in ON position and set the DIP-switches #2 (IN2 75ohm) and #4 (IN1

75ohm) in OFF position and connect the input signal to the BNC IN1 using a "T"

adapter.

Содержание DA-14C-Dual-2

Страница 1: ...2 Dual 1 to 4 Video Distribution Amplifier User Manual English COMM TEC GmbH Siemensstr 14 D 73066 Uhingen Tel 49 7161 3000 0 Fax 49 7161 3000 333 www comm tec de Version A0 July 2007 DBA Copyright b...

Страница 2: ...nection with the use of or inability to use COMM TEC products COMM TEC reserves the right to modify or discontinue designs specifications warranties and policies without notice 1 0 Overview Thank you...

Страница 3: ...ks of an electric shock Only qualified personnel should perform installations 3 0 Settings The unit has no internal settings At the rear side of the unit are 5 user programmable DIP switches 1 IN2 DC...

Страница 4: ...DIP switches 2 and 4 in ON position d Set the DIP switch 3 in OFF position e Set as desired the two DIP switches 1 and 5 to establish the DC or AC coupling f Connect the destinations g Power the DA 1...

Страница 5: ...tcher set the DIP switches 3 IN1 IN2 and 4 IN1 75ohm in ON position Set the DIP switch 2 IN2 75ohm in OFF position and connect the input signal to the BNC IN1 4 4 Linking inputs with T adapter To perf...

Страница 6: ...of the cable run For the best results use RG59 B U coax cable For calibration of the system proceed as follows a Using a TV generator generate a MULTIBURST signal and send it to the DA 14C Dual 2 by t...

Страница 7: ...ency response 0 1 dB at 10 MHz 3 dB at 60 MHz Delay 15 ns Differential gain 0 2 Differential phase 0 8 Hum noise 90 dB unweighted Crosstalk two sections 60 dB at 5 MHz Power 9 Volt AC 500 mA external...