background image

Comfortstar                                                          Service manual for 13seer Cooling Only Condensing 

23

9.5.2 Spare parts list

MIA60-13

No.

discription

Part No.

Qty.

1

Bolt M10× 25

70210231

4

2

Cover Plate

01262202P

1

3

Centrifugal Fan

10358212

1

4

Fan Motor SW300C

15702204

1

5

Motor Mounting Plate Sub-Assy

01322218P

1

6

Bolt M8× 25

70210084

4

7

Compressor

00202205

1

8

Base Plate Sub-Assy

01192205P

1

9

Filter

07219056

1

10

Bidirection Strainer 

07220016

1

11

Tube Clip

021400055

1

12

Cut-off Valve 1-1/8

07138236

1

13

Cut-off Valve 1/2

07138235

1

14

Cabinet

01318206

1

15

Tube-exit plate

01388208

1

16

Electric box cover

01418231

1

17

Capacitor Clamp

02140001

1

18

Capacitor  CBB65 15uF/450V

33010045

1

19

AC Contactor GC6-45S/01C1

44010253

1

20

Terminal Board

42011242

1

21

Terminal Board

420111451

1

22

Capacitor Clamp

02143401

2

23

Capacitor  CBB65 40uF/450V

33000022

2

24

Connection Sheet Sub-Assy

01388219

1

25

Condenser Sub-Assy

01152211

1

26

Side Plate 

01312210P

1

Содержание MIA18-13

Страница 1: ...Service Manual MIA Series Condensing Units Cooling Only 1 5 tons to 5 tons...

Страница 2: ...1 Contents 1 Description of Products Fearures 2 Physical And Electrical Specifications 3 Safety Caution 4 Application 5 Installation Instructions 6 Maintenance Instructions 7 Service And Troubleshooti...

Страница 3: ...rload protection 1 2 Condensing Unit Outline Top discharge air flow with low noise Smaller body with high efficiency With ULcertification Effortless Installation Annular outdoor unit Fast heat dispers...

Страница 4: ...sor and compressed the high temperature and high pressure gas is discharged into heat exchanger of outdoor unit heating exchanges with air of outside and turns into the refrigerant liquid the liquid i...

Страница 5: ...45 0 50 0 Compressor Type Maker ROTARY ROTARY ROTARY SCROLL SCROLL SCROLL SCROLL Model Number 2K21S236A6E 2K28S236A6H QP348KBB ZR30KC PFV 522 ZR36KC PFV 522 ZR42K3 PFV 522 ZR54K3 PFV 522 RLA Rated Lo...

Страница 6: ...0 50 50 100 100 100 100 Outdoor above Indoor Unit 50 50 50 100 100 100 100 Indoor above Outdoor Unit 40 40 40 60 60 60 60 Refrigerant Connection Type Jointing Jointing Jointing Jointing Jointing Joint...

Страница 7: ...ditioner for extended periods Do not climb on or place objects on the air conditioner POWER SUPPLY Adequate power supply adequate cross section of wire Please consult it with distributor and professio...

Страница 8: ...cooling function 86 115 Min cooling function 61 55 Low ambient control kit should be installed when temperature lower than 55 Table1 Unit Dimensions inch Model 18 24 30 42 48 60 length 24 28 28 29 5 H...

Страница 9: ...to deliver treated air along the perimeter of the space If they are too small for their intended air flow the become noisy If they are not located properly they cause drafts on the occupants in the ro...

Страница 10: ...with national and local wiring regulation Quality of installation can affect its operation It is forbidden to fix the unit by users themselves please contact dealer for repair It must be fixed and ad...

Страница 11: ...eeded to hang the unit along the four directions In order to avoid the excursion the angle between the ropes should be less than 40o It is shown as follow 40 Fig 4 Condensing Unit Hoisting Sketch 5 4...

Страница 12: ...good oil return to the compressor it is important to pitch the horizontal suction line toward the compressor approximately 1 2 for every 10 of line 5 5 Line Insulation Suction line requires insulatio...

Страница 13: ...2 1 1 8 1 2 3 3 5 6 7 8 9 10 11 Table 4 The factory charge is sufficient for 25 feet of standard liquid line For longer or shorter liquid line lengths adjust the charge as follows 3 8 Liquid line 0 6...

Страница 14: ...educes performance The presence of moisture in a system can render it inoperable in a very short time Proper evacuation assures a dry uncontaminated system Here is the recommended evacuation procedure...

Страница 15: ...cord or the extension cord and do not connect many devices to one AC outlet It could cause a fire or an electric shock due to defective contact defective insulation exceeding the permissible current e...

Страница 16: ...t is running in the right direction 4 Turn fan switch to AUTO Turn system switch to COOL and turn temperature setting below room temperature Unit should run in cooling mode 5 Check to see if compresso...

Страница 17: ...he accumulator The oil is drawn out through a special port inside the accumulator 9 Refrigerant vapor flows through the suction line to the intake of the compressor The cycle then repeats Electrical T...

Страница 18: ...r 2 Loosening the bolts of the compressor 3 Disengage the Discharge pipe from the vent of the Compressor 4 Disengage the suction pipe from the inspiratory end of the compressor 5 Put the new compresso...

Страница 19: ...irst 2 Connect the pressure gauge to the service vavle you can get the result of the vacuum from the lower pressure gauge 3 Turn on the vacuum pump 4 When the vacuum reaching 1 0kgf cm2 continue 0 5 1...

Страница 20: ...nstruction Air non condensable or moisture in system Recover refrigerant evacuate recharge add filter drier Incorrect voltage At compressor terminals voltage must be within 10 of rating plate volts wh...

Страница 21: ...ressures Incorrect capillary tubes Change coil assembly Blocked outdoor coil Clear away leaves and other debris Refrigerant overcharge Correct system charge Condenser fan not running Repair or replace...

Страница 22: ...Comfortstar Service manual for 13seer Cooling Only Condensing 16 8 Wiring Diagram 8 1 Exterior Wiring Diagram Fig6 8 2 Interior Wiring Diagram Fig7...

Страница 23: ...d Block 01722121 1 6 Axial Flow Fan 10358203 1 7 Compressor 2K21S236A6E 00100234 1 8 Base Plate Sub Assy 01208226 1 9 Filter 07210032 1 10 Bidirectional flter 07220016 1 11 Cut off Valve 5 8 07138234...

Страница 24: ...ompressor 2K21S236A6E 00100233 1 8 Base Plate Sub Assy 01208226 1 9 Filter 07210031 1 10 Bidirectional flter 07220016 1 11 Cut off Valve 5 8 07138234 1 12 Cut off Valve 3 8 07138232 1 13 Pressure swit...

Страница 25: ...4 1 9 filter 07210037 1 10 Bidirectional flter 07220016 1 11 Cut off Valve 3 4 07138233 1 12 Cut off Valve 3 8 07138232 1 13 4 way tie in 06642036 1 14 Pressure switch 460200155 1 15 Cabinet 01318206...

Страница 26: ...Sub Assy 01208232 1 9 filter 07210037 1 10 Bidirectional flter 07220016 1 11 Cut off Valve 3 4 07138233 1 12 Cut off Valve 3 8 07138232 1 13 4 way tie in 06642036 1 14 Cabinet 01318206 1 15 Tube exit...

Страница 27: ...al flter 07220016 1 11 Cut off Valve 3 4 07138233 1 12 Cut off Valve 3 8 07138232 1 13 4 way tie in 06642036 1 14 Cabinet 01318206 1 15 Tube exit plate 01388210 1 16 Electric box cover 01418231 1 17 C...

Страница 28: ...ter 07219056 1 10 Bidirectional flter 07220016 1 11 Cut off Valve 1 1 8 07138236 1 12 Cut off Valve 1 2 07138235 1 13 Cabinet 01318206 1 14 Tube exit plate 01388208 1 15 Electric box cover 01418231 1...

Страница 29: ...lter 07219056 1 10 Bidirection Strainer 07220016 1 11 Tube Clip 021400055 1 12 Cut off Valve 1 1 8 07138236 1 13 Cut off Valve 1 2 07138235 1 14 Cabinet 01318206 1 15 Tube exit plate 01388208 1 16 Ele...

Отзывы: