#ONTROLFANOPERATION

 

(see page 5)

Display 

home screen

#HANGEDATEOR

 

time (see page 4)

Outdoor 

temperature  

and humidity

#URRENTSYSTEM

 

status

Display menu 

options (see 

pages 11-24) 

Adjust 

temperature 

settings (see 

pages 9-10)

Indoor 

temperature  

and humidity

Press to override program temporarily

Thermostat location and 

current program status

Quick reference: commercial use

Select system 

type (see page 6)

Outdoor temperature and humidity are displayed  

ONLYIFANOPTIONALOUTDOORAIRSENSORISINSTALLED

Operating Manual

 

4

69-2687EFS—01

Date/time settings

Press arrow buttons to change

Press date/time display

Press to select date or time

To set the date or time, press the date/
time display, then select 

SET TIME

 or 

SET 

DATE

.

Press the 

V

or 

W

buttons until the 

proper time/date is displayed, then 
press 

DONE

 to save and exit (or press 

CANCEL

 to exit without changing the 

time).

4HETHERMOSTATWILLSWITCHTOANDFROM

Daylight Saving Time automatically. 

MCR32960

ComfortNet™ Communicating Thermostat

 

5

69-2687EFS—01

FAN

MCR32961

p

On

: Fan is always on.

p

Auto

: Fan runs only when heating or 

cooling system is on.

p

Circulate

: Fan runs randomly, about 

35% of the time (residential models 
only).

p

Follow Schedule

: Fan controlled by 

program (see pages 7-8).

Fan settings

In commercial use, the 

CIRCULATE

 option is 

not available.

Press

 

FAN

Press any displayed option

In commercial use, press 

AUTO

 or 

ON

 to 

TEMPORARILYOVERRIDETHEPROGRAMMEDFAN

schedule.

4HEFANSPEEDCANBEADJUSTEDFROM

,OWTO(IGHWHENTHEFANISSETTO

ON

 or 

CIRCULATE

.

Operating Manual

 

6

69-2687EFS—01

Automatic

MCR32964

SYSTEM

MCR32963

System settings

Press any displayed option

Press 

SYSTEM, 

then select any option 

(press 

V

or 

W

to scroll menu):

p

Heat

: Thermostat controls only the 

heating system.

p

Cool

: Thermostat controls only the 

cooling system.

p

Automatic

: Thermostat selects 

heating or cooling as needed. 

p

Off

: Heating and cooling system is 

off. Fan will still operate if fan is set to 
On or Circulate.

p

Emergency Heat

 (only for heat 

pumps with auxiliary heat): 
Thermostat controls Auxiliary Heat. 
Compressor is not used.

Press 

HELP

FORMOREINFORMATIONABOUT

 

these options.

Press 

SYSTEM

Содержание ComfortNet CTK03

Страница 1: ...effect on the amount of energy required to condition your space The facilities team has implemented a schedule as shown below If this schedule does not meet your needs the attached instructions describe how to change the times to better align with your schedule Monday Friday o 6 00AM Wake 70 Heat 74 Cool o 10 00AM Leave 68 Heat 78 Cool o 3 00PM Return 70 Heat 74 Cool o 11 59PM Sleep 68 Heat 78 Coo...

Страница 2: ... overrides 9 Menu options System status 11 Vacation event scheduler 12 Humidity controls 16 Ventilation controls 19 Preferences menu 20 Temporary schedule changes 21 Screen cleaning 22 Security settings 23 Installer contact information 24 Advanced features 25 Appendices Installer options 26 Battery replacement 27 Humidity display 29 Optional accessories 30 In case of difficulty 33 Limited warranty...

Страница 3: ...cally MCR32960 ComfortNet Communicating Thermostat 5 69 2687EFS 01 FAN MCR32961 p On Fan is always on p Auto Fan runs only when heating or cooling system is on p Circulate Fan runs randomly about 35 of the time residential models only p Follow Schedule Fan controlled by program see pages 7 8 Fan settings In commercial use the CIRCULATE option is not available Press FAN Press any displayed option I...

Страница 4: ...AT ANY MENU SCREEN FOR MORE INFORMATION ABOUT SCHEDULE OPTIONS To reduce costs you should use the pre set Energy Saver settings see page 7 Press MENU ComfortNet Communicating Thermostat 9 69 2687EFS 01 Cancel Hold Done MCR32968 Program schedule override residential use Press V or W to change the tempera ture It will be maintained until the hold time you set Press the PERMANENT HOLD button to keep ...

Страница 5: ...ostat 13 69 2687EFS 01 MCR32973 Holiday Event Scheduler MENU MCR32965 Menu Holiday event scheduling commercial use This feature lets you conserve energy when the workplace is unoccupied for special events or on holidays The US United States and CANADIAN options allow you to select from a list of holidays commonly observed in each country You can set the system to unoccupied or occupied mode for th...

Страница 6: ...r number if indoor air is too dry Scroll to select HUMIDIFICATION Set humidity to desired level 7INDOW 0ROTECTION LIMITS THE AMOUNT OF HUMIDITY TO PREVENT FROST OR CONDENSATION ON WINDOWS The Window Protection option is only AVAILABLE IF AN OPTIONAL OUTDOOR SENSOR IS installed MENU MCR32965 Press MENU ComfortNet Communicating Thermostat 17 69 2687EFS 01 MCR32977 Dehumidification Menu Dehumidificat...

Страница 7: ...p Daylight Saving Time options Press HELP FOR MORE INFORMATION ABOUT these options Scroll to select PREFERENCES Press MENU ComfortNet Communicating Thermostat 21 69 2687EFS 01 MCR32982 Temporary Schedule Changes Menu Temporary schedule changes This feature is useful if your daily sched ule sometimes changes Select an option then follow screen prompts to conserve energy while you re away and mainta...

Страница 8: ...ling system earlier to make sure you re comfortable at the time you expect Dehumidification Away Mode Your system can be set to control indoor climate while your home is vacant during the humid season Before you leave press MENU then select DEHUMIDIFICATION AWAY MODE Temperature and humidity will be kept at levels ade quate to protect your home and possessions while you are away When you return pr...

Страница 9: ...ommunicating Thermostat 29 69 2687EFS 01 Humidity display In some circumstances the humidity displayed on the Home screen may not match humidity near the thermostat Some systems are set up to use two sensors one to control humidification the other for dehumidification These sensors are often installed in different locations Depending on how it was configured when installed the thermostat will only...

Страница 10: ...s control is warranted for a period of TEN YEARS except as provided below This warranty applies only if 1 The control is installed in an owner occupied single family residence and 2 The control is installed in conjunction with a new furnace or air handler containing a communicating system that is com patible with the control a Compatible Unit and 3 If the Compatible Unit is a Goodman or Amana bran...

Страница 11: ... IN ACCORDANCE WITH THE INSTRUCTIONS MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OWEVER THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION F THIS EQUIPMENT DOES CAUSE HARMFUL INTERFERENCE TO RADIO OR TELEVISION RECEPTION WHICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON THE USER IS ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OF THE FOL...

Отзывы: