SPECIFICATIONS: 

CZ220 SERIES HEAVY DUTY 5,000W ELECTRIC UTILITY HEATER

WATTS

SWITCH POSITION

VOLTS (VAC)

PHASE

AMPS

BTU/HOUR

5,000W

III

208-240V, 60Hz

1

20.9

17,060

4,000W

II

208-240V, 60Hz

1

16.7

13,650

3,000W

I

208-240V, 60Hz

1

12.5

10,240

N/A

FAN ONLY

N/A

N/A

N/A

N/A

AIR THROW

HORIZONTAL

18 FT (APPROXIMATE)

RECOMMENDED 

CIRCUIT BREAKER

30 AMP

or larger

, in accordance with NEC and local codes.

RECOMMENDED

WIRE SIZE

10 AWG, COPPER ONLY   

RATED AT 167°F/75°C

or larger

, hardwired in accordance with NEC and 

local codes.

RECOMMENDED LUG TORQUES

35 IN-LBS

or greater

, in accordance with NEC and local codes

PRODUCT WEIGHT (APPROXIMATE) 

BETWEEN 25 TO 30 LBS

WARNING

FOR INDOOR USE ONLY, IN A DRY LOCATION FREE OF GASOLINE, PAINT, FLAMMABLE LIQUIDS OR COMBUSTIBLE DUST OR 
MATERIALS.
DO NOT USE EXTENSION CORDS

FOR CZ220 SERIES

Figure 1

NOTE: 

Product dimensions are approximate and subject to change without notice.

Note: Diagram is not drawn to scale, for information purposes only.

HORIZONTAL/ANGLED AIR FLOW:

The maximum recommended ceiling height for effective 

vertical air flow is 8 ft.

MAXIMUM MOUNTING HEIGHT USING BRACKET FOR:

Содержание CZ220 Series

Страница 1: ...t be grounded and hardwired to a properly sized current protection circuit breaker in accordance with the US National Electric Code and local codes Description Adjustable Heat Settings Fan Forced for Wide Heat Circulation Horizontal and Vertical Air Flow with Tilt Feature Sturdy Heavy Gauge Steel Body High Limit Thermal Cut Out Switch ...

Страница 2: ...ter is left operating and unattended 11 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons WARNING Improper installation or failure to follow the procedures outlined in this instruction manual can result in serious electrical shock READ SAVE THESE INSTRUCTIONS WARNING SHOCK HAZARD Use your heater onl...

Страница 3: ... AT 167 F 75 C or larger hardwired in accordance with NEC and local codes RECOMMENDED LUG TORQUES 35 IN LBS or greater in accordance with NEC and local codes PRODUCT WEIGHT APPROXIMATE BETWEEN 25 TO 30 LBS WARNING FOR INDOOR USE ONLY IN A DRY LOCATION FREE OF GASOLINE PAINT FLAMMABLE LIQUIDS OR COMBUSTIBLE DUST OR MATERIALS DO NOT USE EXTENSION CORDS FOR CZ220 SERIES Figure 1 NOTE Product dimensio...

Страница 4: ...st time you operate the unit it may smoke slightly This is due to residual cleaning agents used to clean the element when the heater is manufactured This is normal and does not indicate a problem with the unit This condition will stop after the heater has been in operation for a few minutes Figure 3 MOUNTING BRACKET INSTALLATION Refer to Figures 4a and 4b 1 Locate a ceiling joist or other firm str...

Страница 5: ... certain applications conduit may be required See Figure 6 Check local electrical codes If you run the wiring in conduit and wish to be able to turn the heater be sure to purchase enough flexible conduit to allow the heater to be turned 3 Pull enough wire into the heater and connect to wire to the Power Block located in the electrical area of the heater See Figure 7 4 Be sure to torque all termina...

Страница 6: ...ed to the original retail purchaser against defects in quality or workmanship for a period of one year from the date of original purchase If this unit fails because of a manufacturing defect within 30 days of purchase return the unit with your receipt to the retailer After 30 days but within the warranty period if the unit was purchased within the continental United States return it freight prepai...